Ana Fernandes

Ana Fernandes

Auto-generated profile, based on publicly available information

Ana Fernandes

Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2010 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
Massimo NocenteMassimo Nocente
Massimo Nocente
MTM. Tardocchi
M. Tardocchi
ICI. Chugunov
I. Chugunov
RPR. C. Pereira
R. C. Pereira
TET. Edlington
T. Edlington
JCJet-Efda Contributors
Jet-Efda Contributors
A new high efficiency, high resolution, fast γ -ray spectrometer was recently installed at the JET tokamak. The spectrometer is based on a LaBr3(Ce) scintillator coupled to a photomultiplier tube. A digital data acquisition system is used to allow spectrometry with event rates in excess of 1 MHz expected in future JET DT plasmas. However, at the lower rates typical of present day experiments, digitization can degrade the energy resolution of the system, depending on the algorithms used for extracting pulse height information from the digitized pulses. In this paper, the digital and analog spectrometry methods were compared for different experimental conditions. An algorithm based on pulse shape fitting was developed, providing energy resolution equivalent to the traditional analog spectrometry method.

18 May 2017 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
Massimo NocenteMassimo Nocente
Massimo Nocente
MTM. Tardocchi
M. Tardocchi
RBR. Barnsley
R. Barnsley
LBL. Bertalot
L. Bertalot
BBB. Brichard
B. Brichard
Giuseppe GoriniGiuseppe Gorini
Giuseppe Gorini

11 April 2013 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MNM. Nocente
M. Nocente
MTM. Tardocchi
M. Tardocchi
AOA. Olariu
A. Olariu
SOS. Olariu
S. Olariu
RPR. C. Pereira
R. C. Pereira
Giuseppe GoriniGiuseppe Gorini
Giuseppe Gorini
High resolution γ-ray spectroscopy measurements at MHz counting rates were carried out at nuclear accelerators, combining a LaBr 3 (Ce) detector with dedicated hardware and software solutions based on digitization and off-line analysis. Spectra were measured at counting rates up to 4 MHz, with little or no degradation of the energy resolution, adopting a pile up rejection algorithm. The reported results represent a step forward towards the final goal of high resolution γ-ray spectroscopy measurements on a burning plasma device.

24 April 2012 in Nuclear Fusion
Verified
Journal Article
Closed access
MNM. Nocente
M. Nocente
MTM. Tardocchi
M. Tardocchi
VKV.G. Kiptily
V.G. Kiptily
PBP. Blanchard
P. Blanchard
ICI. Chugunov
I. Chugunov
Giuseppe GoriniGiuseppe Gorini
Giuseppe Gorini
High-resolution γ-ray measurements were carried out on the Joint European Torus (JET) in an experiment aimed at accelerating 4He ions in the MeV range by coupling third harmonic radio frequency heating to an injected 4He beam. For the first time, Doppler broadening of γ-ray peaks from the 12C(d, pγ)13C and 9Be(α, nγ)12C reactions was observed and interpreted with dedicated Monte Carlo codes based on the detailed nuclear physics of the processes. Information on the confined 4He and deuteron energy distribution was inferred, and confined 4He ions with energies as high as 6 MeV were assessed. A signature of MHD activity in γ-ray traces was also detected. The reported results have a bearing on diagnostics for fast ions in the MeV range in next step fusion devices.

1 October 2008 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
MTM. Tardocchi
M. Tardocchi
LPL. I. Proverbio
L. I. Proverbio
Giuseppe GoriniGiuseppe Gorini
Giuseppe Gorini
GGG. Grosso
G. Grosso
MLM. Locatelli
M. Locatelli
JCJet-Efda Contributors
Jet-Efda Contributors
In fusion plasmas gamma ray emission is caused by reactions of fast particles, such as fusion alpha particles, with impurities. Gamma ray spectroscopy at JET has provided valuable diagnostic information on fast fuel as well as fusion product ions. Improvements of these measurements are needed to fully exploit the flux increase provided by future high power experiments at JET and ITER. Limiting aspects are, for instance, the count rate capability due to a high neutron/gamma background combined with slow detector response and a modest energy resolution due to the low light yield of the scintillators. This paper describes the solutions developed for achieving higher energy resolution, signal to background, and time resolution. The detector design is described based on the new BrLa3 scintillator crystal. The paper will focus on hardware development, including a photomultiplier tube capable of stable operation at counting rate as high as 1MHz , the magnetic shielding, and the fast digital data acquisition system.

20 January 2009 in Fusion Engineering and Design
Verified
Journal Article
Closed access
DVD.F. Valcárcel
D.F. Valcárcel
ANA. Neto
A. Neto
JSJ. Sousa
J. Sousa
BCBernardo Brotas Carvalho
Bernardo Brotas Carvalho
HFH. Fernandes
H. Fernandes
JPJ. Písačka
J. Písačka