13 July 2018 in Optics Letters
We demonstrate a highly sensitive and stable fiber-optic Fabry–Perot cantilever microphone based on fast demodulated white-light interferometry. The cavity length of the low-finesse Fabry–Perot interferometry is absolutely measured by realizing a high-speed demodulation method utilizing a full spectrum, with the advantages of both high resolution and large dynamic range. An acoustic test demonstrates high sensitivities and linear responsivities at frequencies below 2 kHz. The pressure responsivity and the noise-limited minimum detectable acoustic pressure level are measured to be 211.2 nm/Pa and , respectively, at the frequency of 1 kHz. Comparative experimental results show that the signal-to-noise ratio is over 10 times higher than a reference condenser microphone.
22 November 2010 in Photonic Sensors
Pressure sensors based on fiber-optic extrinsic Fabry-Perot interferometer (EFPI) have been extensively applied in various industrial and biomedical fields. In this paper, some key improvements of EFPI-based pressure sensors such as the controlled thermal bonding technique, diaphragm-based EFPI sensors, and white light interference technology have been reviewed. Recent progress on signal demodulation method and applications of EFPI-based pressure sensors has been introduced. Signal demodulation algorithms based on the cross correlation and mean square error (MSE) estimation have been proposed for retrieving the cavity length of EFPI. Absolute measurement with a resolution of 0.08 nm over large dynamic range has been carried out. For downhole monitoring, an EFPI and a fiber Bragg grating (FBG) cascade multiplexing fiber-optic sensor system has been developed, which can operate in temperature 300 °C with a good long-term stability and extremely low temperature cross-sensitivity. Diaphragm-based EFPI pressure sensors have been successfully used for low pressure and acoustic wave detection. Experimental results show that a sensitivity of 31 mV/Pa in the frequency range of 100 Hz to 12.7 kHz for aeroacoustic wave detection has been obtained.
10 October 2017 in Journal of Lightwave Technology
We demonstrate a fiber-optic Fabry-Perot acoustic sensor based on a Parylene-C diaphragm of 500 nm in thickness. The excellent diaphragm forming ability and good adhesion of Parylene-C make the sensor fabricate up to 9 mm in diameter. Acoustic testing demonstrates a high dynamic pressure sensitivity of 2239 nm/Pa and a noise limited equivalent acoustic signal level of 22.1 μPa/Hz1/2 at the frequency of 20 Hz. The frequency response exhibits an obvious peak at the frequency of 13 Hz. The sensor can be used for low-frequency acoustic pressure detections, which is necessary in surveillance and security systems.
15 December 2017 in Journal of Lightwave Technology
A fiber-optic Fabry-Perot (F-P) accelerometer with high resolution, high dynamic range, high speed and absolute measurement capability was developed and demonstrated in elevator health monitoring. The sensor element is based on a mesh diaphragm mass-loaded compact structure, and the F-P cavity interrogation was achieved by utilizing a high-speed white light interferometry (WLI) demodulation algorithm. The displacement of inertial mass representing the change of F-P cavity was measured and translated to acceleration in real time. The results indicate a resonance frequency of 270 Hz and axial sensitivity of 3.86 μm/g within the frequency bandwidth of 10-120 Hz for the sensor. In experimental tests, the acceleration resolution achieved 8.5 μg within a $\pm 30 \rm{g}$ maximum measurement range. The performance of the sensing system was compared with a commercialized piezoelectric accelerometer in monitoring the acceleration of an elevator.
10 October 2018 in Optics Letters
An all-optical photoacoustic spectroscopy based on lock-in white-light interferometry is proposed for trace gas detection. The cavity length of the fiber-optic Fabry–Perot cantilever microphone is demodulated by a high-speed white-light interferometer, whose spectral sampling is synchronously triggered by a phased locked signal. To improve the signal-to-noise ratio, the demodulated digital photoacoustic signal is further processed by a specially designed virtual lock-in amplifier. The designed photoacoustic spectrometer has been tested for trace acetylene () detection in the near-infrared region. The normalized noise equivalent absorption coefficient for is achieved to be .
8 February 2019 in Optics Express
We present a fiber-optic photoacoustic (PA) sensor for remote monitoring of gas micro-leakage. The gas sensing head is a miniature ferrule-top PA cavity with a cantilever beam. Gas diffuses into the cavity from the gap around the cantilever beam, and a small hole opens on the side wall. The volume of the optimized PA cavity is only 70 μL. An erbium-doped fiber amplified laser is used as a light source of acoustic excitation. The PA pressure signal is obtained by measuring the deflection of the cantilever beam with a fiber-optic white-light interferometric readout. The experimental result of leaking acetylene (C2H2) gas measurement shows a real-time response of 11.2 s. A detection limit is achieved to be 20 ppb with a 1 s lock-in integration time and a 1 km conductive fiber. Since both the excitation light and probe light are transmitted by the optical fiber, the designed sensing system has the advantages of remote detection and intrinsic safety.