Hongpeng Liu

Hongpeng Liu

Auto-generated profile, based on publicly available information

Hongpeng Liu

Civil Aviation University of China

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2016 in Applied Optics
Verified
Journal Article
Closed access
PDF file
HLHongpeng Liu
Hongpeng Liu
DYDan Yu
Dan Yu
KZKe Zhou
Ke Zhou
DMDongyao Mao
Dongyao Mao
LLLangbo Liu
Langbo Liu
QSQinggong Song
Qinggong Song
Temperature-induced diffraction spectrum responses of holographic gratings are characterized for exploring the temperature-sensing capability of a holographic sensor. Linear blue shift of peak wavelength and linear diffraction reduction are observed. It provides quantitative expressions for sensing applications. Inorganic nanoparticles are dispersed into the binder to improve sensing properties. Obvious improvement of sensing parameters, including wavelength shift and diffraction change, is confirmed. The sensitivity, response rate, and linear response region of holographic sensors are determined to evaluate sensing capacity. Influence of relative humidity on holographic sensing response is discussed. Expansion of humidity range provides a probability for extending the range of wavelength shift. Finally, the temperature response reversibility of a holographic sensor is evaluated. These experimental results can expand the practical application field of holographic sensing strategy and accelerate the development of holographic sensors.

1 June 2012 in Optics & Laser Technology
Verified
Journal Article
Closed access
HLHongpeng Liu
Hongpeng Liu
DYDan Yu
Dan Yu
JWJian Wang
Jian Wang
YJYongyuan Jiang
Yongyuan Jiang
XSXiudong Sun
Xiudong Sun

12 July 2019 in Optics Letters
Verified
Journal Article
Closed access
PDF file
HLHongpeng Liu
Hongpeng Liu
BWBaohua Wang
Baohua Wang
RWRui Wang
Rui Wang
MWMingchang Wang
Mingchang Wang
DYDan Yu
Dan Yu
WWWeibo Wang
Weibo Wang
A spectral confocal displacement and morphology measurement device with a photopolymer-based coaxial holographic lens as a high dispersion element is developed. The linear dependence of the axial spatial position on the peak wavelength of dispersion spectrum provides a high accuracy and large range for measuring displacement and morphology. In the linear dispersion region, accompanied with a 120 nm shift of peak wavelength, the measure position range exceeds 20 mm. The available experimental accuracy of displacement and morphology can reach 47.5 μm/0.5 nm using a commercial optical fiber spectrum with a resolution of 0.5 nm. Utilizing thin polymer-based holographic lens with high dispersion can effectively compact the device size. Simultaneously, it can provide a large axial dispersion for measuring the spatial position characterization compared with the traditional glass-based dispersion lens group. A holographic optical lens based on a photopolymer is expected to apply in high-precision surface morphology measurement of large-scale macroscopic objects. It will improve the measurement accuracy and accelerate the development of holographic optical elements.

2 December 2016 in Applied Optics
Verified
Journal Article
Closed access
PDF file
HLHongpeng Liu
Hongpeng Liu
DYDan Yu
Dan Yu
KZKe Zhou
Ke Zhou
DMDongyao Mao
Dongyao Mao
LLLangbo Liu
Langbo Liu
QSQinggong Song
Qinggong Song
The temperature response mechanism of a diffraction spectrum in a holographic grating is characterized. Two possible major factors, changes in the refractive index and thermal expansion, are measured and analyzed to identify the sensing physical mechanism. Average refractive indices at various temperatures and relative humidity values are independently measured. Thermal optical coefficients of polymers are estimated quantitatively to evaluate the temperature response capability of the refractive index. Angle selectivity of multiplexing gratings is scanned at various temperatures to obtain magnitudes of Bragg angle detuning. The linear thermal expansion coefficients are extracted by the nonlinear fitting reading angle dependence of angle detuning. The significance of the thermal optical coefficient and the thermal expansion coefficient for holographic sensing is discussed. Finally, the primary factor for temperature-induced wavelength blueshift is analyzed theoretically.

18 October 2019 in Applied Optics
Verified
Journal Article
Closed access
PDF file
XJXinying Jiao
Xinying Jiao
HLHongpeng Liu
Hongpeng Liu
BWBaohua Wang
Baohua Wang
RWRui Wang
Rui Wang
LLLi Li
Li Li
A volume grating-based holographic pressure sensor in acrylamide photopolymer has been studied. The pressure sensing response is analyzed using a diffraction spectrum in two kinds of sensor construction methods, i.e., transmission and reflection. In a transmission sensor, the maximum of peak wavelength shifts up to 25 nm under ${1.58} \times {{10}^5}\,\,{\rm Pa}$ pressure. The linear pressure response range exceeds ${2.0} \times {{10}^5}\,\,{\rm Pa}$ and the optimized sensitivity is ${4.9} \times {{10}^3}\,\,{\rm Pa}/{\rm nm}$. Compared to the reflection sensor, the transmission sensor with large slanted angle can provide a more excellent sensing performance. The linear and reversible peak wavelength shifts confirm the applicability of the holographic pressure sensor. A photopolymer-based holographic pressure sensor is expected to apply in a cheap and visual pressure sensing field. The transmission grating is a significant candidate for developing the holographic sensor. These experimental results can accelerate the development and practicality of holographic optical elements.

8 November 2017 in Applied Optics
Verified
Journal Article
Closed access
PDF file
HLHongpeng Liu
Hongpeng Liu
DYDan Yu
Dan Yu
KZKe Zhou
Ke Zhou
SWShichan Wang
Shichan Wang
SLSuhua Luo
Suhua Luo
QSQinggong Song
Qinggong Song
A novel thermo-sensitive N-isopropylacrylamide photopolymer was developed for improving the temperature and humidity responses of holographic sensors. Diffraction spectra of holographic volume gratings recorded in the materials were characterized to explore the sensing response capacity. A dependence of peak wavelength on the temperature was observed and provided a quantitative strategy for holographic sensing applications. Expansion of the humidity range induced a strong extension of wavelength shift. Finally, the temperature response reversibility was demonstrated experimentally. Our sensing results were completely different from the reported typical acrylamide polymer system. Compared with the former, we obtained a more sensitive temperature response and an evident shift expansion (>200  nm) at a relative humidity of 70% or higher. These results can obviously improve the thermo-sensitivity of a holographic sensor and expand the practical application area of the holographic sensing strategy.