Zeng Liu

Zeng Liu

Auto-generated profile, based on publicly available information

Zeng Liu

State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xian Jiaotong University, Xian, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Xin MengXin Meng
Xin Meng
JLJinjun Liu
Jinjun Liu
ZLZeng Liu
Zeng Liu
In this paper, a generalized droop control (GDC) is proposed for a grid-supporting inverter based on a comparison between traditional droop control and virtual synchronous generator (VSG) control. Both the traditional droop control and VSG control have their own advantages, but neither traditional droop control nor VSG control can meet the demand for different dynamic characteristics in grid-connected (GC) and stand-alone (SA) modes at the same time. Rather than using a proportional controller with a low pass filter, as in a traditional droop control, or fully mimicking the conventional synchronous generator (SG) parameters in a VSG control, the active power control loop of the GDC can be designed flexibly to adapt to different requirements. With a well-designed controller, the GDC can achieve satisfactory control performance; unlike a traditional droop control, it can provide virtual inertia and damping properties in stand-alone mode; unlike a VSG control, the output active power of an inverter with GDC can follow changing references quickly and accurately, without large overshoot or oscillation in the grid-connected mode. Moreover, given specific controller parameters, the GDC can function as both a traditional droop control and a VSG control. The GDC's controller parameter design are more intuitive and flexible, and this paper provides a distinct design process. Finally, the effectiveness of the proposed control method is validated by the simulation and experimental results.

18 March 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
BLBaojin Liu
Baojin Liu
ZLZeng Liu
Zeng Liu
JLJinjun Liu
Jinjun Liu
RARonghui An
Ronghui An
HZHaoyang Zheng
Haoyang Zheng
YSYidong Shi
Yidong Shi
To address the unbalanced and harmonic power sharing issue among parallel inverters caused by feeder impedance mismatch in islanded microgrids, an adaptive virtual impedance control method is proposed based on the injection of an extra small AC signal (SACS) in the output voltage of each inverter. Similar to the principle of active power-frequency droop, the frequency of the injected signal droops with the output unbalanced and harmonic power, while the active power produced by the injected SACS is detected to adjust the virtual impedance at the fundamental negative sequence and selected harmonic frequencies, which will tune the distribution of unbalanced and harmonic power in the system. When the injected SACSs of each inverter synchronize with each other and reach a common frequency in steady state, the virtual impedance of each inverter will be matched to each other for evenly sharing the unbalanced and harmonic power. This proposed method requires neither communication links among parallel inverters nor feeder impedance information. Furthermore, the control parameter design method based on modeling and stability analysis of the proposed control structure is discussed in detail. Finally, simulation and experimental results are provided to validate the effectiveness of the proposed scheme.

15 April 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TLTeng Liu
Teng Liu
JLJinjun Liu
Jinjun Liu
ZLZeng Liu
Zeng Liu
ZLZipeng Liu
Zipeng Liu
LCL resonance complicates the design of a current control loop and can even threaten its stability. Extensive approaches have been proposed to deal with this resonance, among which active damping (AD) schemes based on the feedback of a single filter variable have been shown to be effective and cost-efficient. This paper presents a study of such AD techniques, where a generalized approach to developing an AD controller by relating control diagram to equivalent circuit is proposed. Based on this approach, AD controller forms with any one of four commonly used filter variables to realize virtual resistors (VRs) in six different connections to the LCL filter are derived. Comparisons are then made between these 24 AD controller alternatives by considering implementation complexity of the AD controller, the number of measuring sensors, and the effect of the AD controller on the power stage. Consequently, grid-side current feedback AD to realize a VR in parallel with the filter capacitor is selected as a considered alternative. Next, two issues associated with the practical implementation of the selected grid-side current feedback AD, caused by the second-order differential expression and the digital time delay, are discussed and solved. Finally, the selected AD method is analyzed in the discrete z-domain, and its effectiveness is experimentally verified.

1 May 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
SWShike Wang
Shike Wang
ZLZeng Liu
Zeng Liu
JLJinjun Liu
Jinjun Liu
DBDushan Boroyevich
Dushan Boroyevich
RBRolando Burgos
Rolando Burgos
Parallel droop-controlled inverters with renewable energy sources are widely employed in islanded AC microgrids, where dynamic interactions among them may cause small-signal stability issues. Since the active power-frequency droop scheme is applied, the dynamic interactions among inverters exist not only in bus voltage and transmitted current, but also in variable system fundamental frequency. This paper introduces a novel small-signal terminal characteristic model for droopcontrolled inverter. Besides conventional impedance and admittance, a new set of terminal characteristics is proposed to characterize the dynamics of fundamental frequency. Furthermore, the small-signal model of parallel inverters is constructed based on the terminal characteristics of individual inverters. Covering the fundamental frequency interactions, a stability prediction approach based on generalized Nyquist criterion (GNC) is proposed for parallel droop-controlled inverters. Besides the product of impedance and admittance, an additional term is added in the system return ratio, which consists of the proposed terminal characteristics associated with the fundamental frequency. Finally, experimental results validate the effectiveness of this proposed stability prediction approach.

30 March 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
BLBaojin Liu
Baojin Liu
TWTeng Wu
Teng Wu
ZLZeng Liu
Zeng Liu
JLJinjun Liu
Jinjun Liu
In an islanded microgrid composed of droop-controlled parallel inverters, the system frequency endures deviations as the load changes. To compensate for frequency deviation without involving communication infrastructures among distributed generators (DGs), the proportional-integral regulator based secondary frequency control (PI-SFC) method has been proposed and implemented. However, PI-SFC may incur real power-sharing errors because the integrator accumulates disturbances and noise in each DG, leading to different compensation values of nominal real power. To achieve frequency restoration while maintaining equal real power sharing among DGs, this paper proposes a small-AC-signal injection-based secondary frequency control method (SACS-SFC), which is implemented by injecting an additional AC signal into the output voltage of each DG. Furthermore, a droop relation between the frequency of the injected SACS and the compensation value of nominal real power is innovatively established to trim the output real power of each DG to be equal. Frequency deviations caused by primary droop control are thus eliminated, and even real power sharing can be maintained among DGs. Moreover, the control parameters of the proposed SACS-SFC are comprehensively designed via modeling and stability analysis. Simulation and experimental results demonstrate the effectiveness of the proposed method.

15 May 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZLZipeng Liu
Zipeng Liu
JLJinjun Liu
Jinjun Liu
ZLZeng Liu
Zeng Liu
Grid impedance information occupies a fundamental and crucial position for the operation of grid-tied converters. Consequently, accurate and fast extraction of grid impedance is vital. The impulse injection method applied under the control loop of a grid-tied converter, which is commonly used to extract linear grid impedance online, is relatively reasonable in terms of device cost, measurement speed, simplicity, and design flexibility. However, the selection of impulse and design of impulse parameters mostly depend on rules of thumb, without theoretical guidance, leading to insufficient measurement accuracy in target frequency section and greatly burdening the system. To address these issues, a systematic guidance is proposed for analysis, design and implementation of impulse-injection-based grid impedance identification. By comparing the spectra of several basic impulses with unipolar and bipolar forms and analyzing the impact when impulse parameters are altered, a guidance for impulse selection for different measurement scenarios is presented. Based on this guidance, an asymmetric bipolar sawtooth wave with a defined asymmetry ratio of p=0.5 is chosen in this study for broadband measurement of grid impedance. Furthermore, a related parameter design procedure with optimal injection position and instant is also proposed to reduce system burden and eliminate overmodulation when injecting the impulse. Finally, theoretical results are validated by experiments.