10 November 1999 in Physics in Medicine & Biology
Murray's law has been generalized to provide morphometric relationships among various subtrees as well as between a feeding segment and the subtree it perfuses. The equivalent resistance of each subtree is empirically determined to be proportional to the cube of a subtree's cumulative arterial length (L) and inversely proportional to a subtree's arterial volume (V) raised to a power of approximately 2.6. This relationship, along with a minimization of a cost function, and a linearity assumption between flow and cumulative arterial length, provides a power law relationship between V and L. These results, in conjunction with conservation of energy, yield relationships between the diameter of a segment and the length of its distal subtree. The relationships were tested based on a complete set of anatomical data of the coronary arterial trees using two models. The first model, called the truncated tree model, is an actual reconstruction of the coronary arterial tree down to 500 microm in diameter. The second model, called the symmetric tree model, satisfies all mean anatomical data down to the capillary vessels. Our results show very good agreement between the theoretical formulation and the measured anatomical data, which may provide insight into the design of the coronary arterial tree. Furthermore, the established relationships between the various morphometric parameters of the truncated tree model may provide a basis for assessing the extent of diffuse coronary artery disease.
14 February 2013 in Medical Physics
22 February 2010 in Medical Physics
29 November 2012 in Physics in Medicine & Biology
In this study, we investigated the effectiveness of a novel iterative reconstruction (IR) method coupled with dual-dictionary learning (DDL) for image reconstruction in a dedicated breast computed tomography (CT) system based on a cadmium-zinc-telluride (CZT) photon-counting detector and compared it to the filtered-back-projection (FBP) method with the ultimate goal of reducing the number of projections necessary for reconstruction without sacrificing the image quality. Postmortem breast samples were scanned in a fan-beam CT system and were reconstructed from 100 to 600 projections with both IR and FBP methods. The contrast-to-noise ratio (CNR) between the glandular and adipose tissues of the postmortem breast samples was calculated to compare the quality of images reconstructed from IR and FBP. The spatial resolution of the two reconstruction techniques was evaluated using aluminum (Al) wires with diameters of 643, 813, 1020, 1290 and 1630 µm in a plastic epoxy resin phantom with a diameter of 13 cm. Both the spatial resolution and the CNR were improved with IR compared to FBP for the images reconstructed from the same number of projections. In comparison with FBP reconstruction, the CNR was improved from 3.4 to 7.5 by using the IR method with six-fold fewer projections while maintaining the same spatial resolution. The study demonstrated that the IR method coupled with DDL could significantly reduce the required number of projections for a CT reconstruction compared to the FBP method while achieving a much better CNR and maintaining the same spatial resolution. From this, the radiation dose and scanning time can potentially be reduced by a factor of approximately 6 by using this IR method for image reconstruction in a CZT-based breast CT system.
20 December 2010 in Medical Physics
6 July 2012 in Physics in Medicine & Biology
A simple and accurate measurement of breast density is crucial for the understanding of its impact in breast cancer risk models. The feasibility to quantify volumetric breast density with a photon-counting spectral mammography system has been investigated using both computer simulations and physical phantom studies. A computer simulation model involved polyenergetic spectra from a tungsten anode x-ray tube and a Si-based photon-counting detector has been evaluated for breast density quantification. The figure-of-merit (FOM), which was defined as the signal-to-noise ratio of the dual energy image with respect to the square root of mean glandular dose, was chosen to optimize the imaging protocols, in terms of tube voltage and splitting energy. A scanning multi-slit photon-counting spectral mammography system has been employed in the experimental study to quantitatively measure breast density using dual energy decomposition with glandular and adipose equivalent phantoms of uniform thickness. Four different phantom studies were designed to evaluate the accuracy of the technique, each of which addressed one specific variable in the phantom configurations, including thickness, density, area and shape. In addition to the standard calibration fitting function used for dual energy decomposition, a modified fitting function has been proposed, which brought the tube voltages used in the imaging tasks as the third variable in dual energy decomposition. For an average sized 4.5 cm thick breast, the FOM was maximized with a tube voltage of 46 kVp and a splitting energy of 24 keV. To be consistent with the tube voltage used in current clinical screening exam (∼32 kVp), the optimal splitting energy was proposed to be 22 keV, which offered a FOM greater than 90% of the optimal value. In the experimental investigation, the root-mean-square (RMS) error in breast density quantification for all four phantom studies was estimated to be approximately 1.54% using standard calibration function. The results from the modified fitting function, which integrated the tube voltage as a variable in the calibration, indicated a RMS error of approximately 1.35% for all four studies. The results of the current study suggest that photon-counting spectral mammography systems may potentially be implemented for an accurate quantification of volumetric breast density, with an RMS error of less than 2%, using the proposed dual energy imaging technique.