23 February 2007 in Computational Optimization and Applications
28 August 2009 in Optimization Methods and Software
A previously developed approach for solving linear systems arising from interior-point methods applied to linear programming problems is considered and improved upon. The preconditioned conjugate gradient method is used to solve these systems in two different phases of the interior-point method: during the initial interior-point iterations, an incomplete Cholesky factorization preconditioner with controlled fill-in is used; in the second phase, near the optimal solution, a specialized preconditioner based upon the LU factorization is used to combat the high ill-conditioning of the linear systems in this phase. This approach works better than direct methods on some classes of large-scale problems. New heuristics are presented to identify the change of phases, thus achieving better computational results and solving additional problems. Moreover, new orderings of the constraint matrix columns are presented allowing savings in the preconditioned conjugate gradient method iteration number. Experiments are performed with a set of large-scale problems and both approaches are compared with respect to the number of iterations and running time.
1 March 2019 in Computational Optimization and Applications
1 December 2013 in European Journal of Operational Research
1 April 2016 in International Transactions in Operational Research
1 January 2010 in Journal of Industrial and Management Optimization
This paper presents for the first time how to easily incorporate facts devices in an optimal active power flow model such that an efficient interior-point method may be applied. The optimal active power flow model is based on a network flow approach instead of the traditional nodal formulation that allows the use of an efficiently predictor-corrector interior point method speed up by sparsity exploitation. The mathematical equivalence between the network flow and the nodal models is addressed, as well as the computational advantages of the former considering the solution by interior point methods. The adequacy of the network flow model for representing facts devices is presented and illustrated on a small 5-bus system. The model was implemented using Matlab and its performance was evaluated with the 3,397-bus and 4,075- branch Brazilian power system which show the robustness and efficiency of the formulation proposed. The numerical results also indicate an efficient tool for optimal active power flow that is suitable for incorporating facts devices.