17 June 2005 in European Spine Journal
1 May 2012 in Computer Methods in Biomechanics and Biomedical Engineering
In clinical routine, lower limb analysis relies on conventional X-ray (2D view) or computerised tomography (CT) Scan (lying position). However, these methods do not allow 3D analysis in standing position. The aim of this study is to propose a fast and accurate 3D-reconstruction-method based on parametric models and statistical inferences from biplanar X-rays with clinical measurements' (CM) assessment in standing position for a clinical routine use. For the reproducibility study, the 95% CI was under 2.7° for all lower limbs' angular measurements except for tibial torsion, femoral torsion and tibiofemoral rotation ( < 5°). The 95% CI were under 2.5 mm for lower limbs' lengths and 1.5 to 3° for the pelvis' CM. Comparisons between X-rays and CT-scan based 3D shapes in vitro showed mean differences of 1.0 mm (95% CI = 2.4 mm). Comparisons of 2D lower limbs' and 3D pelvis' CM between standing ‘Shifted-Feet’ and ‘Non-Shifted-Feet’ position showed means differences of 0.0 to 1.4°. Significant differences were found only for pelvic obliquity and rotation. The reconstruction time was about 5 min.
25 December 2009 in European Spine Journal
22 February 2008 in Computer Methods in Biomechanics and Biomedical Engineering
In order to reduce the socio-economic burden induced by osteoporotic hip fractures, finite element models have been evaluated as an additional diagnostic tool for fracture prediction. For a future clinical application, the challenge is to reach the best compromise between model relevance and computing time. Based on this consideration, the current study focused on the development and validation of a subject-specific FE-model using an original parameterised generic model and a specific personalization method. A total of 39 human femurs were tested to failure under a quasi-static compression in stance configuration. The corresponding FE-models were generated and for each specimen the numerical fracture load (F FEM) was compared with the experimental value (F EXP), resulting in a significant correlation (F EXP = 1.006 F FEM with r 2 = 0.87 and SEE = 1220 N, p < 0.05) obtained with a reasonable computing time (30 mn). Further in vivo study should confirm the ability of this FE-model to improve the fracture risk prediction.
5 June 2008 in Computer Methods in Biomechanics and Biomedical Engineering
Three-dimensional mechanical modelling of muscles is essential for various biomechanical applications and clinical evaluation, but it requires a tedious manual processing of numerous images. A muscle reconstruction method is presented based on a reduced set of images to generate an approximate parametric object from basic dimensions of muscle contours. A regular volumic mesh is constructed based on this parametric object. The approximate object and the corresponding mesh are deformed to fit the exact muscles contours yielding patient-specific geometry. Evaluation was performed by comparison of geometry to that obtained by contouring all computed tomography (CT) slices, and by quantification of the mesh quality criteria. Muscle fatty infiltration was estimated using a threshold between fat and muscle. Volumic fat index (VFI) of a muscle was computed using first all the complete CT scan slices containing the muscle (VFIref) and a second time only the slices used for reconstruction (VFIrecons). Mean volume error estimation was 2.6% and hexahedron meshes fulfilled quality criteria. VFIrecons respect the individual variation of fat content.