Fabian Bamberg

Fabian Bamberg

Auto-generated profile, based on publicly available information

Fabian Bamberg

Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2023 in Radiology
Verified
Journal Article
Closed access
ARAlexander Rau
Alexander Rau
SRStephan Rau
Stephan Rau
DZDaniela Zöller
Daniela Zöller
AFAnna Fink
Anna Fink
HTHien Tran
Hien Tran
MRMaximilian Russe
Maximilian Russe
Background Radiological imaging guidelines are crucial for accurate diagnosis and optimal patient care as they result in standardized decisions and thus reduce inappropriate imaging studies. Purpose In the present study, we investigated the potential to support clinical decision-making using an interactive chatbot designed to provide personalized imaging recommendations from American College of Radiology (ACR) appropriateness criteria documents using semantic similarity processing. Methods We utilized 209 ACR appropriateness criteria documents as specialized knowledge base and employed LlamaIndex, a framework that allows to connect large language models with external data, and the ChatGPT 3.5-Turbo to create an appropriateness criteria contexted chatbot (accGPT). Fifty clinical case files were used to compare the accGPT's performance against general radiologists at varying experience levels and to generic ChatGPT 3.5 and 4.0. Results All chatbots reached at least human performance level. For the 50 case files, the accGPT performed best in providing correct recommendations that were "usually appropriate" according to the ACR criteria and also did provide the highest proportion of consistently correct answers in comparison with generic chatbots and radiologists. Further, the chatbots provided substantial time and cost savings, with an average decision time of 5 minutes and a cost of 0.19 € for all cases, compared to 50 minutes and 29.99 € for radiologists (both p < 0.01). Conclusion ChatGPT-based algorithms have the potential to substantially improve the decision-making for clinical imaging studies in accordance with ACR guidelines. Specifically, a context-based algorithm performed superior to its generic counterpart, demonstrating the value of tailoring AI solutions to specific healthcare applications.

1 June 2023 in Radiology
Verified
Journal Article
Closed access
MHMuhammad Taha Hagar
Muhammad Taha Hagar
MSMartin Soschynski
Martin Soschynski
RSRuben Saffar
Ruben Saffar
ARAlexander Rau
Alexander Rau
JTJana Taron
Jana Taron
TKTobias Krauss
Tobias Krauss
Background Recently introduced photon-counting CT may improve noninvasive assessment of patients with high risk for coronary artery disease (CAD). Purpose To determine the diagnostic accuracy of ultrahigh-resolution (UHR) coronary CT angiography (CCTA) in the detection of CAD compared with the reference standard of invasive coronary angiography (ICA). Materials and Methods In this prospective study, participants with severe aortic valve stenosis and clinically indicated CT for transcatheter aortic valve replacement planning were consecutively enrolled from August 2022 to February 2023. All participants were examined with a dual-source photon-counting CT scanner using a retrospective electrocardiography-gated contrast-enhanced UHR scanning protocol (tube voltage, 120 or 140 kV; collimation, 120 × 0.2 mm; 100 mL of iopromid; no spectral information). Subjects underwent ICA as part of their clinical routine. A consensus assessment of image quality (five-point Likert scale: 1 = excellent [absence of artifacts], 5 = nondiagnostic [severe artifacts]) and a blinded independent reading for the presence of CAD (stenosis ≥50%) were performed. UHR CCTA was compared with ICA using area under the receiver operating characteristic curve (AUC). Results Among 68 participants (mean age, 81 years ± 7 [SD]; 32 male, 36 female), the prevalence of CAD and prior stent placement was 35% and 22%, respectively. The overall image quality was excellent (median score, 1.5 [IQR, 1.3-2.0]). The AUC of UHR CCTA in the detection of CAD was 0.93 per participant (95% CI: 0.86, 0.99), 0.94 per vessel (95% CI: 0.91, 0.98), and 0.92 per segment (95% CI: 0.87, 0.97). Sensitivity, specificity, and accuracy, respectively, were 96%, 84%, and 88% per participant (n = 68); 89%, 91%, and 91% per vessel (n = 204); and 77%, 95%, and 95% per segment (n = 965). Conclusion UHR photon-counting CCTA provided high diagnostic accuracy in the detection of CAD in a high-risk population, including subjects with severe coronary calcification or prior stent placement. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Williams and Newby in this issue.

10 October 2016 in Diabetes
Verified
Journal Article
Open access
PDF file
FBFabian Bamberg
Fabian Bamberg
HHHolger Hetterich
Holger Hetterich
SRSusanne Rospleszcz
Susanne Rospleszcz
RLRoberto Lorbeer
Roberto Lorbeer
SASigrid D. Auweter
Sigrid D. Auweter
APAnnette Peters
Annette Peters
Detailed pathophysiological manifestations of early disease in the context of prediabetes are poorly understood. This study aimed to evaluate the extent of early signs of metabolic and cardio-cerebrovascular complications affecting multiple organs in individuals with prediabetes. Subjects without a history of stroke, coronary artery disease, or peripheral artery disease were enrolled in a case-control study nested within the Cooperative Health Research in the Region of Augsburg (KORA) FF4 cohort and underwent comprehensive MRI assessment to characterize cerebral parameters (white matter lesions, microbleeds), cardiovascular parameters (carotid plaque, left ventricular function, and myocardial late gadolinium enhancement [LGE]), and metabolic parameters (hepatic proton-density fat fraction [PDFF] and subcutaneous and visceral abdominal fat). Among 400 subjects who underwent MRI, 103 subjects had prediabetes and 54 had established diabetes. Subjects with prediabetes had an increased risk for carotid plaque and adverse functional cardiac parameters, including reduced early diastolic filling rates as well as a higher prevalence of LGE compared with healthy control subjects. In addition, people with prediabetes had significantly elevated levels of PDFF and total and visceral fat. Thus, subjects with prediabetes show early signs of subclinical disease that include vascular, cardiac, and metabolic changes, as measured by whole-body MRI after adjusting for cardiometabolic risk factors.

2 May 2018 in European Radiology
Verified
Journal Article
Open access
PDF file
O(On Behalf Of The European Society Of Cardiovascular Radiology (Escr)
On Behalf Of The European Society Of Cardiovascular Radiology (Escr)
FNFelix Nensa
Felix Nensa
TCthe European Association of Nuclear Medicine (EANM) Cardiovascular Committee
the European Association of Nuclear Medicine (EANM) Cardiovascular Committee
FBFabian Bamberg
Fabian Bamberg
CRChristoph Rischpler
Christoph Rischpler
MHMarcus Hacker
Marcus Hacker
Positron emission tomography (PET) and magnetic resonance imaging (MRI) have both been used for decades in cardiovascular imaging. Since 2010, hybrid PET/MRI using sequential and integrated scanner platforms has been available, with hybrid cardiac PET/MR imaging protocols increasingly incorporated into clinical workflows. Given the range of complementary information provided by each method, the use of hybrid PET/MRI may be justified and beneficial in particular clinical settings for the evaluation of different disease entities. In the present joint position statement, we critically review the role and value of integrated PET/MRI in cardiovascular imaging, provide a technical overview of cardiac PET/MRI and practical advice related to the cardiac PET/MRI workflow, identify cardiovascular applications that can potentially benefit from hybrid PET/MRI, and describe the needs for future development and research. In order to encourage its wide dissemination, this article is freely accessible on the European Radiology and European Journal of Hybrid Imaging web sites. Key Points • Studies and case-reports indicate that PET/MRI is a feasible and robust technology. • Promising fields of application include a variety of cardiac conditions. • Larger studies are required to demonstrate its incremental and cost-effective value. • The translation of novel radiopharmaceuticals and MR-sequences will provide exciting new opportunities.

1 August 2024 in Radiology
Verified
Journal Article
Closed access
BOBenedict Oerther
Benedict Oerther
ANAndrea Nedelcu
Andrea Nedelcu
HEHannes Engel
Hannes Engel
CSChristine Schmucker
Christine Schmucker
GSGuido Schwarzer
Guido Schwarzer
MBMatthias Benndorf
Matthias Benndorf
This systematic review and meta-analysis provides an evidence synthesis of prostate MRI diagnostic performance based on PI-RADS version 2.1 for benchmarking different diagnostic metrics and outcome thresholds.

17 May 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SHSophia D. Heber
Sophia D. Heber
HHHolger Hetterich
Holger Hetterich
RLRoberto Lorbeer
Roberto Lorbeer
CBChristian Bayerl
Christian Bayerl
JMJürgen Machann
Jürgen Machann
FBFabian Bamberg
Fabian Bamberg
Despite the relevance of pancreatic fat content in the development of metabolic diseases, its association with impaired glucose metabolism, diabetes, and other adipose tissue compartments remains unclear. Thus, we determined differences in pancreatic fat content by magnetic resonance imaging (MRI) between subjects with prediabetes, diabetes, and normal controls in a cohort from the general population. Subjects without history of cardiovascular disease with established diabetes or prediabetes as well as normal controls were included and underwent whole-body MRI on a 3T scanner. Pancreatic fat content was quantified by measuring the proton-density fat fraction (PDFFpanc) using a 3D multi-echo GRE sequence (increment: 1.23 ms, 6 echoes) by placing ROIs in the pancreatic head, body, and tail by independent readers. In addition, hepatic fat content as well as abdominal subcutaneous and visceral adipose tissue (SAT and VAT) were measured by multi-echo GRE and 3D 2-point volume-interpolated DIXON MRI, respectively. Univariate and multivariate analyses were employed to determine associations. A total of 385 subjects were included in the analysis (median age: 57 years, 58.2% males), of them 53 were classified as subjects with diabetes, 95 as prediabetes, and 237 as controls (13.8%, 24.7%, and 61.6%; respectively). The median PDFFpanc was 5.2% [IQR 3.3–9.4], and significantly higher in subjects with prediabetes and diabetes as compared to controls (PDFFpanc: 6.2% [IQR: 3.5–12] vs. 8.6% [IQR: 4.3–17.5] vs. 4.9% [3.1–7.4], p0.12). While in univariate analysis BMI, PDFFhepatic, SAT and VAT were associated with PDFFpanc (all p<0.05), only VAT predicted PDFFpanc independently (β: 0.02, 95%-confidence interval: 0.01–0.04, p<0.001). While pancreatic fat content differs significantly between subjects with prediabetes, diabetes and controls, this association may be confounded by age, gender, and the amount of VAT in this cross-sectional study.