Oral Büyüköztürk

Oral Büyüköztürk

Auto-generated profile, based on publicly available information

Oral Büyüköztürk

Massachusetts Institute of Technology

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2015 in Computer-Aided Civil and Infrastructure Engineering
Verified
Journal Article
Open access
PDF file
YCYoung‐Jin Cha
Young‐Jin Cha
OBOral Buyukozturk
Oral Buyukozturk

1 September 2017 in Journal of Infrastructure Systems
Verified
Journal Article
Closed access
JCJustin G. Chen
Justin G. Chen
ADAbe Davis
Abe Davis
NWNeal Wadhwa
Neal Wadhwa
FDFrédo Durand
Frédo Durand
WFWilliam T. Freeman
William T. Freeman
OBOral Büyüköztürk
Oral Büyüköztürk
Visual testing, as one of the oldest methods for nondestructive testing (NDT), plays a large role in the inspection of civil infrastructure. As NDT has evolved, more quantitative techniques have emerged such as vibration analysis. New computer vision techniques for analyzing the small motions in videos, collectively called motion magnification, have been recently developed, allowing quantitative measurement of the vibration behavior of structures from videos. Video cameras offer the benefit of long range measurement and can collect a large amount of data at once because each pixel is effectively a sensor. This paper presents a video camera-based vibration measurement methodology for civil infrastructure. As a proof of concept, measurements are made of an antenna tower on top of the Green Building on the campus of the Massachusetts Institute of Technology (MIT) from a distance of over 175 m, and the resonant frequency of the antenna tower on the roof is identified with an amplitude of 0.21 mm, whic...

12 November 2015 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
HSHao Sun
Hao Sun
OBOral Büyüköztürk
Oral Büyüköztürk
The objective of optimal sensor placement (OSP) is to obtain a sensor layout that gives as much information of the dynamic system as possible in structural health monitoring (SHM). The process of OSP can be formulated as a discrete minimization (or maximization) problem with the sensor locations as the design variables, conditional on the constraint of a given sensor number. In this paper, we propose a discrete optimization scheme based on the artificial bee colony algorithm to solve the OSP problem after first transforming it into an integer optimization problem. A modal assurance criterion-oriented objective function is investigated to measure the utility of a sensor configuration in the optimization process based on the modal characteristics of a reduced order model. The reduced order model is obtained using an iterated improved reduced system technique. The constraint is handled by a penalty term added to the objective function. Three examples, including a 27 bar truss bridge, a 21-storey building at the MIT campus and the 610 m high Canton Tower, are investigated to test the applicability of the proposed algorithm to OSP. In addition, the proposed OSP algorithm is experimentally validated on a physical laboratory structure which is a three-story two-bay steel frame instrumented with triaxial accelerometers. Results indicate that the proposed method is efficient and can be potentially used in OSP in practical SHM.

1 January 2018 in Waste Management
Verified
Journal Article
Closed access
CSCarolyn E. Schaefer
Carolyn E. Schaefer
KKKunal Kupwade-Patil
Kunal Kupwade-Patil
MOMichael Ortega
Michael Ortega
CSCarmen Soriano
Carmen Soriano
OBOral Büyüköztürk
Oral Büyüköztürk
MSMichael P. Short
Michael P. Short

1 November 2018 in Journal of Structural Engineering
Verified
Journal Article
Closed access
JCJustin G. Chen
Justin G. Chen
TATravis M. Adams
Travis M. Adams
HSHao Sun
Hao Sun
EBErin Santini Bell
Erin Santini Bell
OBOral Büyüköztürk
Oral Büyüköztürk
Structural health monitoring (SHM) is a method for determining the structural integrity of civil infrastructure elements as a basis for maintenance and repair protocols. This monitoring depends on collecting structural response data from sensors installed on the structure due to in-service excitations. The installation additionally requires access to structural elements, power, and communication. New methods for remote measurement of displacements using video cameras could greatly simplify the process of instrumentation, making SHM much more attainable for many structures. This paper presents the remote camera measurement of the motions of the World War I Memorial Bridge in Portsmouth, New Hampshire, a vertical-lift bridge, from a distance of over 80 m. Vibration frequencies and mode shapes of the bridge are identified by measuring the displacements due to the lift span impact. Displacement of the bridge due to in-service traffic is also measured. Measured signals are compared with those from accelerometers and strain gauges installed on the bridge, and identified characteristics of the bridge are compared with a finite-element model for verification. Results show the potential of applying video cameras to measure and visualize vibrations of structures in SHM.

1 October 2005 in Journal of Composites for Construction
Verified
Journal Article
Closed access
CAChing Au
Ching Au
OBOral Buyukozturk
Oral Buyukozturk
This paper explores the effects of fiber orientation and ply mix on load–deformation behavior and failure modes of fiber reinforced polymer (FRP) confined concrete by testing under uniaxial compression a designed array of plain concrete cylinders wrapped with different fabric orientation. Depending on the jacket confinement stiffness, either a strain hardening or a strain softening behavior was observed beyond the kink point where there was a sharp reduction in slope in the load–deformation curve. Kinking was seen to have a definable graphical relationship with the critical concrete lateral strain while the kink stress was found to upshift with increasing jacket stiffness. It is concluded that while hoop fiber wrapped concrete leads to brittle failures, angular fiber wrapped concrete tends to fail in a ductile manner, attributed to a fiber reorientation mechanism. Ply mix sequence plays an important role in the overall deformation and failure behavior. Existing models are found to be adequate in describin...