J. Erik Loehr

J. Erik Loehr

Auto-generated profile, based on publicly available information

J. Erik Loehr

Univ. of Texas Rio Grande Valley

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2007 in Journal of Materials in Civil Engineering
Verified
Journal Article
Closed access
CCCheng-Wei Chen
Cheng-Wei Chen
HSHani Salim
Hani Salim
JBJohn J. Bowders
John J. Bowders
JLJ. Erik Loehr
J. Erik Loehr
JOJacob Owen
Jacob Owen
Slender recycled plastic pins (RPPs) can be used to stabilize earthen slopes by driving the RPPs into the face of the slope to intercept the sliding surface and “pin” the slope. The RPPs will be subjected to lateral (bending) forces, and their ability to resist deformation will strongly influence the success of the RPPs for stabilizing slopes. Arrhenius modeling was used to predict the time for the RPPs to reach creep failure. Engineering properties and strain rate effect of four different types of RPPs were evaluated and are reported in this paper. Arrhenius modeling showed creep failure ranged from 50 to 3,900 years at field temperature and stress levels. Compressive strengths ranged from 11 to 20 MPa and compressive moduli from 580 to 1,280 MPa at 1% strain, while flexural strengths ranged from 9 to 25 MPa and flexural moduli from 620 to 1675 MPa at 1% strain.

1 December 2017 in Journal of Geotechnical and Geoenvironmental Engineering
Verified
Journal Article
Closed access
TVThuy Vu
Thuy Vu
ELErik Loehr
Erik Loehr
A new service limit state (SLS) design procedure for drilled shafts is described, which utilizes strength resistance factors calibrated to achieve a target probability of failure. The new procedure can be used for varying values of the target probability of failure, and allows the shaft dimensions, soil strength, variability of soil strength, loads, and allowable settlement to be adjusted freely in the design. The procedure eliminates the need to establish resistance factors for the SLS on a case-by-case basis, which is a current practical issue for load and resistance factor design (LRFD). Sensitivity analyses presented indicate that resistance factors for a broad set of SLS design conditions can be reasonably established considering four parameters: the target probability of failure, normalized load, normalized shaft dimension, and the variability of soil/rock strength. Calibrated resistance factors are presented as a function of these four parameters in the form of resistance factor charts, as well as in the form of analytical equations developed through regression of the rigorously calibrated resistance factors. The proposed resistance factors range from 0.1 to 0.4, primarily because of the significant variability and uncertainty associated with side resistance for drilled shafts in shale.

25 February 2013
Verified
Conference Paper
Closed access
SHSung-Chi Hsu
Sung-Chi Hsu
JMJulio Maldonado
Julio Maldonado
ELErik Loehr
Erik Loehr
JBJohn Bowders
John Bowders
ELEric Lindsey
Eric Lindsey
WOWilliam Omatsone
William Omatsone
Large model tests, 4.25 x 2.4 x 1.6 m, were performed on slopes composed of silty sand (SM) compacted dry of optimum water content to a slope of 25 degrees and then tilted to 30 degrees. An apparatus that simulates rainfall was placed on the slope with a rainfall pattern that was deemed appropriate for the desired results. Instrumentation including tensiometers, pressure transducers, and extensometers were placed inside the slope at several locations. With the data collected from the instrumentation, analysis of the behavior of the slope over time was used to determine the critical failure information. The change of suction and pore pressure with time close to the slope surface and at different depths were recorded. Thus, the infiltration pattern was observed and the infiltration rate can be estimated based on the experimental results. The experimental results show that a slope may easily fail under rainfall conditions. The failure initiated close to the toe due to infiltration and seepage that reduced the suction in the soil, i.e. higher pore pressure and lower effective stress, in this region. The toe failure subsequently lead to retrogressive failure along the slope. The results of this research can be used to understand and establish the stability of slopes in similar soils under various rainfall conditions to improve prediction of these events in order to mitigate their effects.

24 July 2000
Verified
Conference Paper
Closed access
JBJohn J. Bowders
John J. Bowders
JLJ. Erik Loehr
J. Erik Loehr
JOJacob W. Owen
Jacob W. Owen
Loess, a uniform-sized, wind-blown, cohesive soil can be problematic in geotechnical engineering applications. Natural deposits have high strength and exhibit stable vertical slopes; however, dramatic collapse can occur when loess becomes saturated. In remolded, compacted applications, the behavior of loess is less well known. Regionally (central USA), embankments of compacted loess can exhibit deformation and slope failure after years of service. The initial phase of a larger effort to characterize the strength behavior of compacted loess is reported herein. This phase is limited to assessing the short-term, undrained shear strength of compacted loess. Undrained strengths of compacted loess were measured to be up to 500 to 650 kPa. Higher compactive effort, dry of optimum water content, maximizes the undrained strength. Modified Proctor energy increased undrained shear strength by up to 2.5 to 3.0 times higher than loess compacted at the same water contents using standard energy. Loess compacted at or greater than optimum moisture content, as determined in the standard Proctor test, had similar undrained strength (100 to 200 kPa) regardless of the compactive effort. In order to maximize short term strength of compacted loess, use the greatest compactive effort and compact the soil well dry of optimum moisture content.

24 February 2014
Verified
Conference Paper
Closed access
DDDan Ding
Dan Ding
WLWilliam J. Likos
William J. Likos
JLJ. Erik Loehr
J. Erik Loehr
A comprehensive research program was recently completed to evaluate variability and uncertainty in geotechnical design parameters, including those used for consolidation and settlement analyses. Numerous one-dimensional consolidation tests were conducted following incremental load and constant rate of strain loading procedures for specimens obtained from four different sites using "state of the practice" and "state of the art" sampling techniques. The four sites included two "soft clay" sites, one "soft silt" site, and a "stiff silt/clay" site. Laboratory consolidation tests were conducted on specimens from each site to determine compression and recompression indices, preconsolidation stress, and coefficients of consolidation. Results from different sampling and testing methods are compared to draw conclusions regarding the variability and uncertainty associated with consolidation parameters obtained following different sampling and testing protocols. "State of the art" boring, sampling, and testing methods were found to produce lower values of preconsolidation stress, greater values of compression index, and similar values of recompression index and coefficient of consolidation compared with results from "state of the practice" methods for the three soft soil sites. Variability and uncertainty in consolidation parameters determined from state of the art methods were also found to be notably less than the variability and uncertainty established using state of the practice methods for the soft soil sites while the variability and uncertainty in consolidation parameters for the stiff soil site were similar for both state of the art and state of the practice methods.

21 September 2007
Verified
Conference Paper
Closed access
BGBidjan Ghahreman
Bidjan Ghahreman
JLJ. Erik Loehr
J. Erik Loehr
EAEng-Chew Ang
Eng-Chew Ang
A power company is constructing air quality control (AQC) additions at a power plant site in Alabama, USA. The selected location for the AQC additions is near an area that has experienced periodic but regular lateral ground movements. An extensive study was carried out to investigate the magnitude and rate of movements and the factors controlling these movements. A slope stabilization scheme involving construction of one hundred 1.37 meter (m) (54 inch [in.]) diameter drilled shafts adjacent to the AQC additions was implemented to arrest lateral movements. A program of field instrumentation and monitoring was implemented to verify key assumptions during construction, evaluate the effectiveness of the stabilization scheme, and provide information that could be used to modify the stabilization scheme if field observations identified this necessity. Instrumentation included inclinometer casings within selected drilled shafts, inclinometer casings in soil between the shafts and landward of the stabilized area, fiber optic strain gages on shaft reinforcement, standpipe piezometers, and clusters of fiber optic pressure transducers. Data from the instrumentation was collected throughout construction and has proven to be instrumental in evaluating the performance of the stabilization scheme.