12 September 2018 in Physical Review Letters
We report on a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of , resulting in a 1.0 ton yr exposure. The energy region of interest, (), exhibits an ultralow electron recoil background rate of . No significant excess over background is found, and a profile likelihood analysis parametrized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross section for WIMP masses above , with a minimum of at and a 90% confidence level.
30 October 2017 in Physical Review Letters
We report the first dark matter search results from XENON1T, a -target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind. The blinded search used 34.2 live days of data acquired between November 2016 and January 2017. Inside the fiducial mass and in the energy range of interest for weakly interacting massive particle (WIMP) dark matter searches, the electronic recoil background was , the lowest ever achieved in such a dark matter detector. A profile likelihood analysis shows that the data are consistent with the background-only hypothesis. We derive the most stringent exclusion limits on the spin-independent WIMP-nucleon interaction cross section for WIMP masses above , with a minimum of for WIMPs at 90% C.L.
1 November 2016 in Journal of Cosmology and Astroparticle Physics
17 December 2019 in Physical Review Letters
We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of () tonne day. Above , we observe , which is more than 1000 times lower than in similar searches with other detectors. Despite observing a higher rate at lower energies, no DM or CEvNS detection may be claimed because we cannot model all of our backgrounds. We thus exclude new regions in the parameter spaces for DM-nucleus scattering for DM masses within , DM-electron scattering for , and absorption of dark photons and axionlike particles for within .
1 April 2016 in Journal of Cosmology and Astroparticle Physics
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.The total electronic recoil background in 1 tonne fiducial volume and (1, 12) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is (1.80 ± 0.15) · 10−4(kg·day·keV)−1, mainly due to the decay of222Rn daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region (4, 50) keV, is composed of (0.6 ± 0.1) (t·y)−1from radiogenic neutrons, (1.8 ± 0.3) · 10−2(t·y)−1from coherent scattering of neutrinos, and less than 0.01 (t·y)−1from muon-induced neutrons. The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency ℒeff, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a 2 y measurement in 1 t fiducial volume, the sensitivity reaches a minimum cross section of 1.6 · 10−47cm2at mχ = 50 GeV/c2.
12 October 2020 in Physical Review D
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 tonne-years and an unprecedentedly low background rate of between 1 and 30 keV, the data enable one of the most sensitive searches for solar axions, an enhanced neutrino magnetic moment using solar neutrinos, and bosonic dark matter. An excess over known backgrounds is observed at low energies and most prominent between 2 and 3 keV. The solar axion model has a significance, and a three-dimensional 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by , , and , and excludes either or . The neutrino magnetic moment signal is similarly favored over background at , and a confidence interval of (90% C.L.) is reported. Both results are in strong tension with stellar constraints. The excess can also be explained by decays of tritium at significance with a corresponding tritium concentration in xenon of . Such a trace amount can neither be confirmed nor excluded with current knowledge of its production and reduction mechanisms. The significances of the solar axion and neutrino magnetic moment hypotheses are decreased to and , respectively, if an unconstrained tritium component is included in the fitting. With respect to bosonic dark matter, the excess favors a monoenergetic peak at (68% C.L.) with a global ( local) significance over background. This analysis sets the most restrictive direct constraints to date on pseudoscalar and vector bosonic dark matter for most masses between 1 and . We also consider the possibility that may be present in the detector, yielding a 2.82 keV peak from electron capture. Contrary to tritium, the concentration can be tightly constrained and is found to be negligible.