Sidhartha Panda

Sidhartha Panda

Auto-generated profile, based on publicly available information

Sidhartha Panda

Department of Electrical Engineering, Veer Surendra Sai University of Technology, Burla, India

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2014 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
BSBinod Kumar Sahu
Binod Kumar Sahu
SPSwagat Pati
Swagat Pati
SPSidhartha Panda
Sidhartha Panda
A novel fuzzy proportional–integral derivative (PID) controller is proposed in this study for automatic generation control (AGC) of interconnected power systems. The optimum gains of the proposed fuzzy PID controller are optimised employing a hybrid differential evolution particle swarm optimisation (DEPSO) technique using an integral of time multiplied by absolute value of error criterion. The superiority of hybrid DEPSO algorithm over differential evolution and particle swarm optimisation (PSO) algorithm has also been demonstrated. The results are also compared with some recently published approaches such as artificial bee colony and PSO based proportional–integral/PID controllers for the same interconnected power systems. Furthermore, performance of the proposed system is analysed by varying the different parameters such as loading condition, system parameters and objective functions. It is observed that the optimum gains of the proposed fuzzy PID controller need not be reset even if the system is subjected to variation in loading condition and system parameters. Finally, the study is extended to a three area system considering generation rate constraint to demonstrate the ability of the proposed approach to cope with multiple interconnected systems. Comparison with previous AGC methods reported in the literature validates the significance of the proposed approach.

28 May 2014 in Electric Power Components and Systems
Verified
Journal Article
Closed access
PMPradeep K. Mohanty
Pradeep K. Mohanty
BSBinod Kumar Sahu
Binod Kumar Sahu
SPSidhartha Panda
Sidhartha Panda
—This article presents an approach for obtaining proportional–integral–derivative controller parameters for an automatic voltage regulator system based on a local unimodal sampling optimization algorithm. A conventional integral time of squared error objective function and modified objective functions in terms of integral time of absolute error, integral of absolute error, integral of squared error, peak overshoot, and settling time with appropriate weighting factors are employed to tune the controller parameters. Different objective functions are employed to obtain optimized proportional–integral–derivative controller gains. Superiority of proposed technique over some recently published modern heuristic optimization techniques, such as artificial bee colony algorithm, particle swarm optimization algorithm, and differential evolution algorithm, for the same automatic voltage regulator system is demonstrated. Simulation results reveal that the proposed proportional–integral–derivative controlled automatic voltage regulator system tuned by the local unimodal sampling algorithm with modified objective function exhibits better performance in terms of settling time, peak overshoot, and stability. The robustness of the system tuned by the proposed algorithm is also studied satisfactorily by varying the time constants of the automatic voltage regulator system in the range of –50% to +50% in steps of 25%.


11 February 2019 in World Journal of Engineering
Verified
Journal Article
Closed access
PSPrakash Chandra Sahu
Prakash Chandra Sahu
RPRamesh Chandra Prusty
Ramesh Chandra Prusty
SPSidhartha Panda
Sidhartha Panda
Purpose: The paper has proposed to implement gray wolf optimization (GWO)-based filter-type proportional derivative with (FPD) plus (1+ proportional integral) multistage controller in a three-area integrated source-type interlinked power network for achieving automatic generation control. Design/methodology/approach: For analysis, a three area interconnected power system of which each area comprises three different generating units where thermal and hydro system as common. Micro sources like wind generator, diesel generator and gas unit are integrated with area1, area2 and area3 respectively. For realization of system nonlinearity some physical constraints like generation rate constraint, governor dead band and boiler dynamics are effected in the system. Findings: The supremacy of multistage controller structure over simple proportional integral (PI), proportional integral, derivative (PID) and GWO technique over genetic algorithm, differential evolution techniques has been demonstrated. A comparison is made on performances of different controllers and sensitivity analysis on settling times, overshoots and undershoots of different dynamic responses of system as well as integral based error criteria subsequent a step load perturbation (SLP). Finally, sensitive analysis has been analyzed by varying size of SLP and network parameters in range ±50 per cent from its nominal value. Originality/value: Design and implementation of a robust FPD plus (1 + PI) controller for AGC of nonlinear power system. The gains of the proposed controller are optimized by the application of GWO algorithm. An investigation has been done on the dynamic performances of the suggested system by conducting a comparative analysis with conventional PID controller tuned by various optimization techniques to verify its supremacy. Establishment of the robustness and sensitiveness of the controller by varying the size and position of the SLP, varying the loading of the system randomly and varying the time constants of the system.

13 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
SNSmruti Ranjan Nayak
Smruti Ranjan Nayak
RKRajendra Khadanga
Rajendra Khadanga
SPSidhartha Panda
Sidhartha Panda
PSPreeti Ranjan Sahu
Preeti Ranjan Sahu
SPSasmita Padhy
Sasmita Padhy
Taha Selim UstunTaha Selim Ustun
Taha Selim Ustun
In this article, a novel methodology is proposed by utilizing a technique which, in light of the change in the African vulture optimization known as Sine Cosine, adopted an African vulture optimization algorithm (SCaAVOA)-based tilt integral derivative (TID) regulator for the load frequency control (LFC) of a five-area power system with multi-type generations. At first, the execution of the Sine Cosine-adopted calculation is tried by contrasting it with the standard AVOA calculation while considering different standard benchmark functions. To demonstrate the superiority of the proposed SCaAVOA algorithm, the results are contrasted using different standard approaches. In the next stage, the proposed method is used in a five-area thermal power system and is likewise applied to a five-area, ten-unit system comprising different conventional sources as well as some renewable energy sources. The performance analysis of the planned regulator is completed for various system boundaries and loading conditions. It is seen that the said regulator is more viable in comparison to the other standard controllers.

15 January 2021 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
DMDebidasi Mohanty
Debidasi Mohanty
SPSidhartha Panda
Sidhartha Panda