Zhuyin Chu

Zhuyin Chu

Auto-generated profile, based on publicly available information

Zhuyin Chu

State Key Laboratory of Lithospheric and Environmental Coevolution, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing 100029, China

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2009 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
ZCZhuyin Chu
Zhuyin Chu
FCFukun Chen
Fukun Chen
YYYueheng Yang
Yueheng Yang
JGJinhui Guo
Jinhui Guo
In this paper, a high sensitivity method for measurements of Nd isotopes as NdO+, on a TIMS using a single W filament with TaF5 as an ion emitter is presented. Although analyzing Nd isotopes as oxides (NdO+) is a well known technique, this is the first report to analyze Nd isotopic compositions as oxides using W filaments and the TaF5 emitter. When 0.5–1 ng loads of a Neodymium isotopic reference reagent, JNdi-1, were measured using this method, the ion yields were found to be mostly in excess of 15% and could be as high as 32%. Internal precision on 143Nd/144Nd could be better than 10 ppm (2SE) for 1 ng JNdi-1 loads and better than 15 ppm (2SE) for 0.5 ng JNdi-1 loads; thirteen replicates of 0.5–1 ng JNdi-1 loads yielded a 143Nd/144Nd value of 0.512112 ± 0.000028 (2SD). Compared with the previously reported NdO+ measurement method using the Re (or W) filaments + Silica-gel + H3PO4 loading techniques, this method has advantages including higher sensitivity, a more stable ion beam, and no need for oxygen gas to be bled into the ion source chamber. Sm isotopes were analyzed as Sm+ using the W filaments and the TaF5 emitter, and high sensitivity and good ion beam stability were also obtained. Several international rock reference materials, including an ultramafic rock reference material USGS PCC-1 that contains very low amounts of Sm and Nd, were analyzed with full column chemistry and the TaF5 method, and the results of Sm, Nd concentrations and Nd isotopic data are in good agreement with the reported values. Combined with a highly efficient and low-blank column chemistry to separate Nd from Sm, Ce, and Pr, this method holds potential to analyze Sm, Nd concentrations and Nd isotopic compositions of highly depleted peridotites; very small aliquots of minerals such as garnets; extra-terrestrial materials of limited sample size; and environmental samples that contain very low quantities of Sm and Nd.

14 June 2014 in Geostandards and Geoanalytical Research
Verified
Journal Article
Closed access
PDF file
ZCZhuyin Chu
Zhuyin Chu
YYYan Yan
Yan Yan
ZCZhi Chen
Zhi Chen
JGJinghui Guo
Jinghui Guo
YYYueheng Yang
Yueheng Yang
YZYanbin Zhang
Yanbin Zhang


2 August 2019 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
ZCZhu-Yin Chu
Zhu-Yin Chu
MWMeng-Jie Wang
Meng-Jie Wang
CLChao-Feng Li
Chao-Feng Li
YYYue-Heng Yang
Yue-Heng Yang
JXJun-Jie Xu
Jun-Jie Xu
JGJing-Hui Guo
Jing-Hui Guo
A single-stage TODGA column for the separation of Nd from geological materials for isotope analysis as NdO + by TIMS.

22 October 2016 in Geochemistry, Geophysics, Geosystems
Verified
Journal Article
Closed access
PDF file
ZCZhuyin Chu
Zhuyin Chu
HHHuaiyu He
Huaiyu He
JRJahandar Ramezani
Jahandar Ramezani
SBSamuel A. Bowring
Samuel A. Bowring
DHDongyu Hu
Dongyu Hu
JGJinghui Guo
Jinghui Guo

21 June 2013 in Geostandards and Geoanalytical Research
Verified
Journal Article
Closed access
PDF file
ZCZhuyin Chu
Zhuyin Chu
JGJinghui Guo
Jinghui Guo
YYYueheng Yang
Yueheng Yang
LQLiang Qi
Liang Qi
CLChaofeng Li
Chaofeng Li