Taiji Sakamoto

Taiji Sakamoto

Auto-generated profile, based on publicly available information

Taiji Sakamoto

Department of Ophthalmology, Kagoshima University, Kagoshima, Japan

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2015 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
SSShozo Sonoda
Shozo Sonoda
TSTaiji Sakamoto
Taiji Sakamoto
TYTakehiro Yamashita
Takehiro Yamashita
EUEisuke Uchino
Eisuke Uchino
HKHiroki Kawano
Hiroki Kawano
TITatsuro Ishibashi
Tatsuro Ishibashi

1 June 2014 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
SSShozo Sonoda
Shozo Sonoda
TSTaiji Sakamoto
Taiji Sakamoto
TYTakehiro Yamashita
Takehiro Yamashita
MSMakoto Shirasawa
Makoto Shirasawa
EUEisuke Uchino
Eisuke Uchino
MTMasatoshi Tomita
Masatoshi Tomita
Purpose.: To determine changes in choroidal structure by binarization of optical coherence tomographic (OCT) images. Methods.: Choroidal images were recorded by enhanced depth imaging OCT. The subfoveal choroidal images were analyzed, and the luminal and interstitial areas were converted to binary images by the Niblack method. The interrater, intrarater, and intersession agreements of the binary images were determined for healthy eyes. In eyes with age-related macular degeneration (AMD), the binary images of the choroid before photodynamic therapy (PDT) were compared to those after PDT. The untreated fellow eyes were studied as controls. Results.: In healthy eyes, the average ratio of the luminal to choroidal area was 65.4%. The interrater agreement rate was high, with intraclass correlation coefficient (ICC) 0.985 and 0.988 for the choroid and luminal areas, respectively. The intrarater ICC was 0.996 for the choroid and 0.997 for the luminal areas. The intersession ICC was 0.993 for the choroid and 0.984 for the luminal areas. In eyes with AMD, the subfoveal choroidal area, the luminal area, and the interstitial areas were thinner 6 months after PDT (all P < 0.01, Wilcoxon signed-rank sum test). The ratio of the luminal to choroidal area was significantly decreased to 62.8% (P < 0.01, Wilcoxon signed-rank sum test). The ratio for the fellow eyes was not significantly changed. Conclusions.: The Niblack binarization method can be used to analyze the luminal area of choroid in an OCT image with good repeatability and reproducibility. The change in the subfoveal choroidal area after PDT is due mainly to a decrease in the luminal areas.

1 March 2012 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
TYToshifumi Yamashita
Toshifumi Yamashita
TYTakehiro Yamashita
Takehiro Yamashita
MSMakoto Shirasawa
Makoto Shirasawa
NANoboru Arimura
Noboru Arimura
HTHiroto Terasaki
Hiroto Terasaki
TSTaiji Sakamoto
Taiji Sakamoto
Purpose.: To compare subfoveal choroidal thickness (SCT) measurements of three different commercially available spectral-domain optical coherence tomography instruments with healthy eyes of Japanese. Methods.: A prospective, cross-sectional study was performed at a single institution. SCT of the right eye of 43 normal subjects was measured using three different SD-OCTs: Heidelberg Spectralis-OCT (Spectralis), Cirrus HD-OCT (Cirrus), and Topcon 3D OCT-1000 Mark II (Topcon). Two separate measurements were performed for the same eye with a maximum by a single examiner. SCT was defined as the distance from the posterior edge of the retinal pigment epithelium to the choroid/sclera junction. After manual segmentation, measurements were made using calipers equipped on each machine by masked raters. Intraclass, interrater, and intermachine agreements were assessed. Results.: Forty-three subjects (mean age, 30.5 years) were enrolled. Of 43 eyes, the SCT of 39 eyes (90.7%) could be measured using each machine. Intraclass correlation coefficients (95% confidence intervals) were 0.976 (0.954–9.987), 0.958 (0.919–0.978), and 0.939 (0.895–0.971) with Spectralis, Cirrus, and Topcon, respectively. Interrater correlation coefficients (95% confident interval) were 0.944 (0.893 to 0.971), 0.956 (0.831 to 0.983), and 0.924 (0.825 to 0.964) with Spectralis, Cirrus, and Topcon, respectively. The average SCT was 272.6, 272.8, and 269.2 μm with Spectralis, Cirrus, and Topcon, respectively. The intermachine correlation coefficient was significantly high among the machines (P < 0.001, Spearman), 0.97 (Spectralis–Cirrus), 0.96 (Cirrus–Topcon), and 0.98 (Topcon–Cirrus). Bland–Altman plot analysis showed no typical trend among the machines. Conclusions.: SCT measurements obtained with three different SD-OCTs were highly correlated and could be used interchangeably. (http://upload.umin.ac.jp number, UMIN000005287.)

1 November 2013 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
YMYukiko Matsuo
Yukiko Matsuo
TSTaiji Sakamoto
Taiji Sakamoto
TYTakehiro Yamashita
Takehiro Yamashita
MTMasatoshi Tomita
Masatoshi Tomita
MSMakoto Shirasawa
Makoto Shirasawa
HTHiroto Terasaki
Hiroto Terasaki
Purpose.: We compared the subfoveal choroidal thickness (SFCT) measured on the images obtained by two spectral-domain optical coherence tomographic (SD-OCT) instruments and one swept-source OCT (SS-OCT) instrument. Methods.: A cross-sectional, prospective noninterventional study was done in which SFCT was measured in the images obtained by two SD-OCT instruments; Heidelberg Spectralis-OCT (Spectralis-SD-OCT) and Topcon 3D OCT-1000 Mark II (Topcon-SD-OCT). Images also were obtained with SS-OCT Atlantis DRI OCT-1 (DRI-SS-OCT). After manual segmentation, the measurements were made using the calipers embedded in each instrument. The intrarater, interrater, and intermachine agreements were assessed. Results.: We studied 35 subjects. The intrarater correlation coefficient (95% confidence interval) was 0.994 (0.988–0.994) for Spectralis-SD-OCT, 0.996 (0.993–0.998) for Topcon-SD-OCT, and 0.997 (0.991–0.998) for DRI-SS-OCT (P < 0.001). The interrater correlation coefficient was 0.995 (0.991–0.998) for Spectralis-SD-OCT, 0.995 (0.990–0.998) for Topcon-SD-OCT, and 0.996 (0.992–0.998) for DRI-SS-OCT (P < 0.001). The average SFCT was 273.2 μm with Spectralis-SD-OCT, 269.1 μm with the Topcon-SD-OCT, and 280.5 μm with DRI-SS-OCT. The intermachine correlation coefficient was 0.982 (0.964–0.991) for Spectralis-SD-OCT versus Topcon-SD-OCT, 0.907 (0.815–0.953) for Topcon-SD-OCT versus DRI-SS-OCT, and 0.911 (0.832–0.954) for DRI-SS-OCT versus Spectralis-SD-OCT (P < 0.001). The SFCT measured with DRI-SS-OCT was significantly thicker than that with Topcon-SD-OCT, with a mean difference of 11.41 ± 30.27 μm (P = 0.032). Conclusions.: In normal adult eyes, there was good reproducibility and repeatability of SFCT measurements obtained by the SD-OCT and SS-OCT instruments. However, the choroid measured with DRI-SS-OCT was thicker than that measured with both SD-OCT instruments, and, thus, the choroidal thickness should not be compared between the SD-OCT and SS-OCT instruments. (www.umin.ac.jp/ctr number, UMIN000011259.)

1 February 2011 in Retina
Verified
Journal Article
Closed access
TSTaiji Sakamoto
Taiji Sakamoto
TITatsuro Ishibashi
Tatsuro Ishibashi
To review the present understanding of hyalocytes. A review of recent studies that investigated the roles of hyalocytes in the pathophysiology of the vitreous cavity. Studies on immunocytochemistry and chimeric mice with green fluorescent protein transgenic mice show that hyalocytes belong to the monocyte/macrophage lineage and derive from bone marrow. The effects of hyalocytes on the vitreous cavity environment can be divided into three categories: synthesis of extracellular matrix, regulation of the vitreous cavity immunology, and modulation of inflammation. In noninflamed eyes, vitreous cavity is an immune-privileged site that is maintained by a system called vitreous cavity-associated immune deviation, in which hyalocytes play the role of antigen-presenting cells. However, cultured hyalocytes proliferate in response to inflammatory molecules and secrete vascular endothelial growth factor and urokinase-type plasminogen activator. A collagen gel embedded with hyalocytes contracts over time, which is enhanced by transforming growth factor-β but is inhibited by Rho kinase inhibitor. These results suggest that hyalocytes can be an exacerbating factor in inflamed eyes. Clinically, hyalocytes are frequently found in the surgically removed specimens of epiretinal membrane or proliferative vitreoretinopathy. Elucidating the properties of hyalocytes is important to understand the biology of vitreous cavity and to develop novel treatments for vitreoretinal diseases.

1 February 2006 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
SSShozo Sonoda
Shozo Sonoda
Katsuro TachibanaKatsuro Tachibana
Katsuro Tachibana
EUEisuke Uchino
Eisuke Uchino
AOAkiko Okubo
Akiko Okubo
MYMatsuo Yamamoto
Matsuo Yamamoto
TSTaiji Sakamoto
Taiji Sakamoto
Purpose. The cornea is an ideal organ for evaluating gene transfer because it can be treated noninvasively and monitored easily. The present study was performed to investigate the practical efficacy and safety of ultrasound (US) plus microbubble (MB)–mediated gene transfer to cornea. methods. Cultured rabbit corneal epithelial (RC-1) cells were incubated in 24-well dishes with plasmid DNA having a green fluorescent protein (GFP) gene under a cytomegalovirus promoter. The cells were exposed to US under different intensities (1 MHz; power, 0.5∼2 W/cm2; duration, 15–120 seconds; duty cycle, 20%–100%). The effect of simultaneous stimulation with MBs was also examined. Gene transfer was quantified by counting the number of GFP-positive cells under microscopy. Furthermore, in vivo gene transfer was examined by GFP plasmid injection into rabbit cornea and US exposure with MBs. results. In the in vitro study, DNA exposure alone could not transfer gene into cultured RC-1 cells; US enhanced gene transfer slightly. Coexposure with MBs significantly increased gene transfer efficiency. In the in vivo study, DNA injection alone could transfer the gene to a limited degree, but plasmid injection plus US with MBs strongly increased gene transfer efficiency without apparent tissue damage, and gene transfer was achieved two dimensionally. conclusions. US with MBs greatly increases gene transfer to in vivo and in vitro corneal cells. This noninvasive gene transfer method may be a useful tool for clinical gene therapy.