Seong Keun Kwon

Seong Keun Kwon

Auto-generated profile, based on publicly available information

Seong Keun Kwon

Department of Otorhinolaryngology-Head and Neck Surgery Seoul National University Hospital Seoul Korea

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Journal of Controlled Release
Verified
Journal Article
Closed access
Ji Hyun RyuJi Hyun Ryu
Ji Hyun Ryu
JCJi Suk Choi
Ji Suk Choi
EPEunsook Park
Eunsook Park
MEMin Rye Eom
Min Rye Eom
SJSeongyeon Jo
Seongyeon Jo
HLHaeshin Lee
Haeshin Lee

30 November 2015 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
SKSu-Hwan Kim
Su-Hwan Kim
HLHak Rae Lee
Hak Rae Lee
SYSeung Jung Yu
Seung Jung Yu
MHMin-Eui Han
Min-Eui Han
DLDoh Young Lee
Doh Young Lee
Nathaniel HwangNathaniel Hwang
Nathaniel Hwang
In this study, we present a method for assembling biofunctionalized paper into a multiform structured scaffold system for reliable tissue regeneration using an origami-based approach. The surface of a paper was conformally modified with a poly(styrene-co-maleic anhydride) layer via initiated chemical vapor deposition followed by the immobilization of poly-l-lysine (PLL) and deposition of Ca2+. This procedure ensures the formation of alginate hydrogel on the paper due to Ca2+ diffusion. Furthermore, strong adhesion of the alginate hydrogel on the paper onto the paper substrate was achieved due to an electrostatic interaction between the alginate and PLL. The developed scaffold system was versatile and allowed area-selective cell seeding. Also, the hydrogel-laden paper could be folded freely into 3D tissue-like structures using a simple origami-based method. The cylindrically constructed paper scaffold system with chondrocytes was applied into a three-ring defect trachea in rabbits. The transplanted engineered tissues replaced the native trachea without stenosis after 4 wks. As for the custom-built scaffold system, the hydrogel-laden paper system will provide a robust and facile method for the formation of tissues mimicking native tissue constructs. Significance This work describes an intriguing strategy for the formation of hydrogel-laden multiform structures utilizing paper sheets and suggests a route for trachea tissue engineering. It combines concepts extracted from paper origami, functional thin polymer coating, and thin hydrogel layering on top of the paper scaffolds. A computer-aided design-based lock-and-key arrangement was used for folding the sheets into multiform structures with spatial arrangements. With encapsulating cells in hydrogel-laden paper, the scaffold system was able to deliver biological cues in vivo. In this work, we have successfully applied an origami-based tissue engineering approach to the trachea regeneration model.

9 March 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
IKIn Gul Kim
In Gul Kim
SPSu A. Park
Su A. Park
SLShin-Hyae Lee
Shin-Hyae Lee
JCJi Suk Choi
Ji Suk Choi
HCHana Cho
Hana Cho
SKSeong Keun Kwon
Seong Keun Kwon
For successful tracheal reconstruction, tissue-engineered artificial trachea should meet several requirements, such as biocompatible constructs comparable to natural trachea, coverage with ciliated respiratory mucosa, and adequate cartilage remodeling to support a cylindrical structure. Here, we designed an artificial trachea with mechanical properties similar to the native trachea that can enhance the regeneration of tracheal mucosa and cartilage through the optimal combination of a two-layered tubular scaffold and human induced pluripotent stem cell (iPSC)-derived cells. The framework of the artificial trachea was fabricated with electrospun polycaprolactone (PCL) nanofibers (inner) and 3D-printed PCL microfibers (outer). Also, human bronchial epithelial cells (hBECs), iPSC-derived mesenchymal stem cells (iPSC-MSCs), and iPSC-derived chondrocytes (iPSC-Chds) were used to maximize the regeneration of tracheal mucosa and cartilagein vivo. After 2 days of cultivation using a bioreactor system, tissue-engineered artificial tracheas were transplanted into a segmental trachea defect (1.5-cm length) rabbit model. Endoscopy did not reveal granulation ingrowth into tracheal lumen. Alcian blue staining clearly showed the formation of ciliated columnar epithelium in iPSC-MSC groups. In addition, micro-CT analysis showed that iPSC-Chd groups were effective in forming neocartilage at defect sites. Therefore, this study describes a promising approach for long-term functional reconstruction of a segmental tracheal defect.

14 August 2018 in Polymers
Verified
Journal Article
Open access
PDF file
SKSong Kwon
Song Kwon
SLSeunghun S. Lee
Seunghun S. Lee
ASA. Sivashanmugam
A. Sivashanmugam
JKJanet (Jung Hoo) Kwon
Janet (Jung Hoo) Kwon
SKSeung Hyun L. Kim
Seung Hyun L. Kim
Nathaniel HwangNathaniel Hwang
Nathaniel Hwang
Cryogels have recently gained interest in the field of tissue engineering as they inherently possess an interconnected macroporous structure. Considered to be suitable for scaffold cryogel fabrication, methacrylated gelatin (GelMA) is a modified form of gelatin valued for its ability to retain cell adhesion site. Bioglass nanoparticles have also attracted attention in the field due to their osteoinductive and osteoconductive behavior. Here, we prepare methacrylated gelatin cryogel with varying concentration of bioglass nanoparticles to study its potential for bone regeneration. We demonstrate that an increase in bioglass concentration in cryogel leads to improved mechanical property and augmented osteogenic differentiation of mesenchymal cells during in vitro testing. Furthermore, in vivo testing in mice cranial defect model shows that highest concentration of bioglass nanoparticles (2.5 w/w %) incorporated in GelMA cryogel induces the most bone formation compared to the other tested groups, as studied by micro-CT and histology. The in vitro and in vivo results highlight the potential of bioglass nanoparticles incorporated in GelMA cryogel for bone regeneration.

1 September 2019 in Acta Biomaterialia
Verified
Journal Article
Closed access
YCYoung Hwan Choi
Young Hwan Choi
SKSu-Hwan Kim
Su-Hwan Kim
IKIn-Seon Kim
In-Seon Kim
KKKyungMin Kim
KyungMin Kim
SKSeong Keun Kwon
Seong Keun Kwon
Nathaniel HwangNathaniel Hwang
Nathaniel Hwang

1 January 2017 in Otology & Neurotology
Verified
Journal Article
Closed access
MSMyung-Whan Suh
Myung-Whan Suh
JPJae Hong Park
Jae Hong Park
SKSeong Il Kang
Seong Il Kang
JLJae Hyun Lim
Jae Hyun Lim
MPMoo Kyun Park
Moo Kyun Park
SKSeong Keun Kwon
Seong Keun Kwon
Objectives: The aim of this study was to quantitatively measure the tightness of the goggle strap during the video head impulse test (vHIT) and to identify slippage-induced artifacts according to tightness. We aimed to elucidate the mechanism of faulty gain caused by goggle slippage and explain the typical artifacts associated with it. Subjects and Methods: An endotracheal tube cuff manometer was coupled to the EyeSeeCam vHIT system (Interacoustics, Assens, Denmark) to monitor strap tightness. The instantaneous gain (40, 60, and 80 ms) and regression gain were compared in eight healthy subjects under the following strap tightness conditions: loose (25 cm H2O), tight (35 cm H2O), and very tight (45 cm H2O). To elucidate the mechanism of faulty gain caused by goggle slippage, a fake fixed pupil with a vestibule ocular reflex (VOR) gain of 0 was attached to the subject's eyelid. The faulty gain recording pattern was analyzed as the tightness of the strap was decreased. Results: The most common slippage-induced artifacts were: 1) initial backward eye movement toward the head movement, 2) acceleration bumps, 3) high gain, and 4) deceleration bumps. At 40 ms, the gain was significantly lower in the 25 cm H2O condition (0.68 ± 0.32 cm H2O) compared with the 45 cm H2O condition (0.90 ± 0.26 cm H2O). At 80 ms, the gain was higher for the 25 cm H2O condition (1.24 ± 0.27 cm H2O) compared with the 45 cm H2O condition (1.16 ± 0.30 cm H2O). These findings were progressively more obvious as the tightness of the strap decreased in a dose-dependent manner. When the fake pupil was recorded, initial backward eye movement toward the head movement (negative VOR gain) and eye tracing mimicking a small VOR (positive VOR gain) were recorded, despite the fake pupil having absolutely no movement. These artifact recordings are presumed to be related to the faulty low (40 ms) and high (80 ms) gain calculation. Conclusions: Slippage-induced artifacts are presumed to be because of the slingshot-like movement of the goggles during head movement in three different phases (lagging, overshooting, and bouncing of the goggles). Monitoring the pressure of the strap tightness may be a solution for minimizing this slippage. A strap tightness of at least 45 cm H2O is required for reliable vHIT recording and gain calculations.