Tamara Miner Haygood

Tamara Miner Haygood

Auto-generated profile, based on publicly available information

Tamara Miner Haygood

University of Texas MD Anderson Cancer Center

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2011 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
THTamara Miner Haygood
Tamara Miner Haygood
JWJason Wong
Jason Wong
JLJennifer Cha Lin
Jennifer Cha Lin
SLSylvia Li
Sylvia Li
AMAurelio Matamoros
Aurelio Matamoros
JMJohn E. Madewell
John E. Madewell

1 January 2012 in Clinical Radiology
Verified
Journal Article
Closed access
THT.M. Haygood
T.M. Haygood
KMK. Malhotra
K. Malhotra
CNC. Ng
C. Ng
BCB. Chasen
B. Chasen
KMK.W. McEnery
K.W. McEnery
MCM. Chasen
M. Chasen

7 June 2010 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
GMGautam S. Muralidhar
Gautam S. Muralidhar
ABAlan C. Bovik
Alan C. Bovik
JGJ. David Giese
J. David Giese
MSMehul P. Sampat
Mehul P. Sampat
Gary WhitmanGary Whitman
Gary Whitman
MMMia K. Markey
Mia K. Markey
We have developed a novel, model-based active contour algorithm, termed “snakules”, for the annotation of spicules on mammography. At each suspect spiculated mass location that has been identified by either a radiologist or a computer-aided detection (CADe) algorithm, we deploy snakules that are converging open-ended active contours also known as snakes. The set of convergent snakules have the ability to deform, grow and adapt to the true spicules in the image, by an attractive process of curve evolution and motion that optimizes the local matching energy. Starting from a natural set of automatically detected candidate points, snakules are deployed in the region around a suspect spiculated mass location. Statistics of prior physical measurements of spiculated masses on mammography are used in the process of detecting the set of candidate points. Observer studies with experienced radiologists to evaluate the performance of snakules demonstrate the potential of the algorithm as an image analysis technique to improve the specificity of CADe algorithms and as a CADe prompting tool.

1 December 2011 in Clinical Genitourinary Cancer
Verified
Journal Article
Closed access
GMGeorge E. Manoukian
George E. Manoukian
NTNizar M. Tannir
Nizar M. Tannir
EJEric Jonasch
Eric Jonasch
WQWei Qiao
Wei Qiao
THTamara M. Haygood
Tamara M. Haygood
Shi-Ming TuShi-Ming Tu
Shi-Ming Tu

1 January 2013 in British Journal of Radiology
Verified
Journal Article
Closed access
THT M Haygood
T M Haygood
JRJ Ryan
J Ryan
PBP C Brennan
P C Brennan
SLS Li
S Li
EME M Marom
E M Marom
DCD Chakraborty
D Chakraborty
Choosing an acceptance radius or proximity criterion is necessary to analyse free-response receiver operating characteristic (FROC) observer performance data. This is currently subjective, with little guidance in the literature about what is an appropriate acceptance radius. We evaluated varying acceptance radii in a nodule detection task in chest radiography and suggest guidelines for determining an acceptance radius. 80 chest radiographs were chosen, half of which contained nodules. We determined each nodule's centre. 21 radiologists read the images. We created acceptance radii bins of <5 pixels, <10 pixels, <20 pixels and onwards up to <200 and 200+ pixels. We counted lesion localisations in each bin and visually compared marks with the borders of nodules. Most reader marks were tightly clustered around nodule centres, with tighter clustering for smaller than for larger nodules. At least 70% of readers' marks were placed within <10 pixels for small nodules, <20 pixels for medium nodules and <30 pixels for large nodules. Of 72 inspected marks that were less than 50 pixels from the centre of a nodule, only 1 fell outside the border of a nodule. The acceptance radius should be based on the larger nodule sizes. For our data, an acceptance radius of 50 pixels would have captured all but 2 reader marks within the borders of a nodule, while excluding only 1 true-positive mark. The choice of an acceptance radius for FROC analysis of observer performance studies should be based on the size of larger abnormalities.

24 August 2015 in Sultan Qaboos University Medical Journal
Verified
Journal Article
Open access
THTamara Miner Haygood
Tamara Miner Haygood
MSMohamed Sayyouh
Mohamed Sayyouh
JWJason Wong
Jason Wong
JLJennifer C. Lin
Jennifer C. Lin
AMAurelio Matamoros
Aurelio Matamoros
JMJohn E. Madewell
John E. Madewell
This study aimed to raise radiologists' awareness of skeletal muscle metastases (SMM) in renal cell carcinoma (RCC) cases and to clarify their imaging appearance. A retrospective analysis was undertaken of 21 patients between 44-75 years old with 72 SMM treated from January 1990 to May 2009 at the MD Anderson Cancer Center in Houston, Texas, USA. Additionally, 37 patients with 44 SMM from a literature review were analysed. Among the 21 patients, the majority of SMM were asymptomatic and detected via computed tomography (CT). Mean metastasis size was 18.3 mm and the most common site was the trunk muscles (83.3%). The interval between discovery of the primary tumour and metastasis detection ranged up to 234 months. Peripheral enhancement (47.1%) was the most common post-contrast CT pattern and non-contrasted CT lesions were often isodense. Magnetic resonance imaging (MRI) characteristics were varied. Five lesions with available T1-weighted pre-contrast images were hyperintense to the surrounding muscle. Other organ metastases were present in 20 patients. Of the 44 SMM reported in the literature, the majority were symptomatic. Average metastasis size was 53.4 mm and only 20.5% of SMM were in trunk muscles. The average interval between tumour discovery and metastasis detection was 101 months. Other organ metastases were recorded in 17 out of 29 patients. SMM should always be considered in patients with RCC, even well after primary treatment. SMM from RCC may be invisible on CT without intravenous contrast; contrast-enhanced studies are therefore recommended. SMM are often hyperintense to the surrounding muscle on T1-weighted MRI scans.