19 August 2008 in Acta Anaesthesiologica Scandinavica
1 May 2014 in The Thoracic and Cardiovascular Surgeon
In a microbiological sample study of 15 wet-primed cardiopulmonary bypass circuits in standby mode for 72 hours under regular clinical conditions, no contamination of the priming fluid or the connectors could be detected. Hand contact surfaces of the machines demonstrated environmental microorganisms. These findings indicate the safe use of primed cardiopulmonary bypass circuits in standby mode for 72 hours. A surface disinfection of hand contact surfaces immediately before use is recommended.
1 January 2013 in Der Anaesthesist
9 January 2015 in Infection Control & Hospital Epidemiology
25 July 2016 in Infection Control & Hospital Epidemiology
11 March 2016 in Krankenhaushygiene up2date
Basishygiene und aseptisches Arbeiten sind auch für das Anästhesieteam im OP das A und O der Infektionsprävention. Auf die intraoperative Händedesinfektion – v. a. beim Umgang mit Medikamenten und beim Zuspritzen – muss vermehrt geachtet werden. Propofolreste sind sorgfältig auszuspülen und besondere Vorsicht ist beim Umgang mit Propofol geboten. Durch gute Arbeitsorganisation lässt sich die Umgebungskontamination des Anästhesiearbeitsplatzes reduzieren. Auf die zeitgerechte Gabe des richtigen Antibiotikums in richtiger Dosis bei bestehender Indikation zur PAP ist zu achten.