26 October 2020 in Nature Nanotechnology
30 April 2018 in Nature Nanotechnology
Numerous living organisms possess biophotonic nanostructures that provide colouration and other diverse functions for survival. While such structures have been actively studied and replicated in the laboratory, it remains unclear whether they can be used for biomedical applications. Here, we show a transparent photonic nanostructure inspired by the longtail glasswing butterfly (Chorinea faunus) and demonstrate its use in intraocular pressure (IOP) sensors in vivo. We exploit the phase separation between two immiscible polymers (poly(methyl methacrylate) and polystyrene) to form nanostructured features on top of a Si3N4 substrate. The membrane thus formed shows good angle-independent white-light transmission, strong hydrophilicity and anti-biofouling properties, which prevent adhesion of proteins, bacteria and eukaryotic cells. We then developed a microscale implantable IOP sensor using our photonic membrane as an optomechanical sensing element. Finally, we performed in vivo testing on New Zealand white rabbits, which showed that our device reduces the mean IOP measurement variation compared with conventional rebound tonometry without signs of inflammation.
18 December 2017 in Microsystems & Nanoengineering
Intraocular pressure (IOP) is a key clinical parameter in glaucoma management. However, despite the potential utility of daily measurements of IOP in the context of disease management, the necessary tools are currently lacking, and IOP is typically measured only a few times a year. Here we report on a microscale implantable sensor that could provide convenient, accurate, on-demand IOP monitoring in the home environment. When excited by broadband near-infrared (NIR) light from a tungsten bulb, the sensor’s optical cavity reflects a pressure-dependent resonance signature that can be converted to IOP. NIR light is minimally absorbed by tissue and is not perceived visually. The sensor’s nanodot-enhanced cavity allows for a 3–5 cm readout distance with an average accuracy of 0.29 mm Hg over the range of 0–40 mm Hg. Sensors were mounted onto intraocular lenses or silicone haptics and secured inside the anterior chamber in New Zealand white rabbits. Implanted sensors provided continuousin vivotracking of short-term transient IOP elevations and provided continuous measurements of IOP for up to 4.5 months.
4 February 2022 in Science Advances
Understanding and controlling the nanoscale transport of excitonic quasiparticles in atomically thin two-dimensional (2D) semiconductors are crucial to produce highly efficient nano-excitonic devices. Here, we present a nanogap device to selectively confine excitons or trions of 2D transition metal dichalcogenides at the nanoscale, facilitated by the drift-dominant exciton funneling into the strain-induced local spot. We investigate the spatiospectral characteristics of the funneled excitons in a WSe 2 monolayer (ML) and converted trions in a MoS 2 ML using hyperspectral tip-enhanced photoluminescence imaging with <15-nm spatial resolution. In addition, we dynamically control the exciton funneling and trion conversion rate by the gigapascal-scale tip pressure engineering. Through a drift-diffusion model, we confirm an exciton funneling efficiency of ∼25% with a significantly low strain threshold (∼0.1%), which sufficiently exceeds the efficiency of ∼3% in previous studies. This work provides a previously unexplored strategy to facilitate efficient exciton transport and trion conversion of 2D semiconductor devices.
2 February 2022 in Nanophotonics
Tunable metasurfaces can change the optical properties of incident light at will such as amplitude, phase, and polarization in a time‐dependent fashion. Ultrafast switching speed and the ability for the pixel size reduction of the tunable metasurface can allow various applications such as light detection and ranging, interferometric sensors, and free space optical communications, to name a few. Although there have been successful demonstrations of the wavefront shaping using the tunable metasurface, the implementation of the two‐dimensional metasurface pixel array that can be individually addressed in the optical frequency regime still remains challenging. Here, we present the experimental demonstration of the two‐dimensional beam steering with the metasurface array by the binary phase grating in the infrared regime. The metasurface unit cell is composed of metal–dielectric–oxide structure with the indium tin oxide as an active layer, which is modulated by using the top fan‐out electrodes. The metasurface array is two‐dimensionally pixelated and has the phase change above 137° in the infrared regime.
29 August 2023 in Nature Communications
Measuring, recording and analyzing spectral information of materials as its unique finger print using a ubiquitous smartphone has been desired by scientists and consumers. We demonstrated it as drug classification by chemical components with smartphone Raman spectrometer. The Raman spectrometer is based on the CMOS image sensor of the smartphone with a periodic array of band pass filters, capturing 2D Raman spectral intensity map, newly defined as spectral barcode in this work. Here we show 11 major components of drugs are classified with high accuracy, 99.0%, with the aid of convolutional neural network (CNN). The beneficial of spectral barcodes is that even brand name of drug is distinguishable and major component of unknown drugs can be identified. Combining spectral barcode with information obtained by red, green and blue (RGB) imaging system or applying image recognition techniques, this inherent property based labeling system will facilitate fundamental research and business opportunities.