Daejun Chang

Daejun Chang

Auto-generated profile, based on publicly available information

Daejun Chang

Korea Advanced Institute of Science and Technology (KAIST)

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
JAJunkeon Ahn
Junkeon Ahn
DCDaejun Chang
Daejun Chang

1 December 2014 in Ships and Offshore Structures
Verified
Journal Article
Closed access
SSSuwon Seo
Suwon Seo
BCBongsik Chu
Bongsik Chu
YNYeelyong Noh
Yeelyong Noh
WJWonhee Jang
Wonhee Jang
SLSangick Lee
Sangick Lee
DCDaejun Chang
Daejun Chang
This paper proposes a methodology for economic evaluations of liquefied natural gas fuel gas supply (LNG–FGS) systems. To evaluate the economics of various LNG–FGS systems, expected operating expenditures during long-term voyages were compared, including the loss from venting boil-off gas (BOG) to prevent overpressurisation of the fuel tank, penalties for venting BOG, expenses for consuming marine diesel oil when LNG–FGS systems are unavailable, and expenses for electricity consumption. A secondary objective was to compare the economics of various LNG–FGS systems for large-sized ships. An analysis demonstrated that the comparative operational expenditures vary considerably within various design options. Three LNG–FGS systems were compared. As a case study, an Aframax tanker (a highly popular crude carrier) was chosen, and the actual voyage scenario between Ulsan and Antwerp was used for calculating expenses. The results indicated that group FP-P (fully pressurised-type storage tank with cryogenic pump) provides a profit of approximately 7 MUS$ per 25 yrs compared to group UP-P (unpressurised-type storage tank with cryogenic pump); conversely, group FP-P incurs a loss of approximately 5.4 MUS$ per 25 yrs compared to group FP-N (fully pressurised-type storage tank with vapour-generating unit). Nevertheless, group FP-N is valuable for small-sized tanks because the vapour-generating unit requires high energy consumption during an extended initial time to raise pressure. In conclusion, group FP-P is the most economical system if it can compensate for approximately 5.4 MUS$ in capital expenditure and maintenance costs. The proposed methodology reflects the availability of necessary equipment and the results of process dynamic simulation in an actual voyage scenario.

1 March 2016 in Structural Safety
Verified
Journal Article
Closed access
SLSeong-Yeob Lee
Seong-Yeob Lee
CJChoonghee Jo
Choonghee Jo
PBPål Bergan
Pål Bergan
BPBjørnar Pettersen
Bjørnar Pettersen
DCDaejun Chang
Daejun Chang

19 March 2015 in Energies
Verified
Journal Article
Open access
PDF file
KKKwangu Kang
Kwangu Kang
YSYoungkyun Seo
Youngkyun Seo
DCDaejun Chang
Daejun Chang
SKSeong-Gil Kang
Seong-Gil Kang
CHCheol Huh
Cheol Huh
In this study, a techno–economic model was used to calculate the costs of CO2 transport and specify the major equipment required for transport in order to demonstrate and implement CO2 sequestration in the offshore sediments of South Korea. First, three different carbon capture and storage demonstration scenarios were set up involving the use of three CO2 capture plants and one offshore storage site. Each transport scenario considered both the pipeline transport and ship transport options. The temperature and pressure conditions of CO2 in each transport stage were determined from engineering and economic viewpoints, and the corresponding specifications and equipment costs were calculated. The transport costs for a 1 MtCO2/year transport rate were estimated to be US$33/tCO2 and US$28/tCO2 for a pipeline transport of ~530 km and ship transport of ~724 km, respectively. Through the economies of scale effect, the pipeline and ship transport costs for a transport rate of 3 MtCO2/year were reduced to approximately US$21/tCO2 and US$23/tCO2, respectively. A CO2 hub terminal did not significantly reduce the cost because of the short distance from the hub to the storage site and the small number of captured sources.

1 April 2014 in Journal of Marine Science and Technology
Verified
Journal Article
Closed access
PDF file
SYSungtae Yun
Sungtae Yun
JRJiheon Ryu
Jiheon Ryu
SSSuwon Seo
Suwon Seo
SLSangick Lee
Sangick Lee
HCHyun Chung
Hyun Chung
DCDaejun Chang
Daejun Chang

5 September 2013 in Ships and Offshore Structures
Verified
Journal Article
Closed access
KKKi-Hong Kim
Ki-Hong Kim
KYKyung Won Yang
Kyung Won Yang
SJSangkwon Jeong
Sangkwon Jeong
KNKiil Nam
Kiil Nam
DCDaejun Chang
Daejun Chang
This study demonstrated the feasibility of an absorption refrigeration system (ARS) that is capable of utilising the engine exhaust gas of bulk gas carriers as the heat source and generating cooling source either for reliquefaction of the boil-off gas (BOG) or for heating, ventilating and air conditioning. The ARS employed an NH3/H2O mixture as the working fluid. The process was designed and simulated using the properties of the exhaust gas from the commercially available engines. The coefficient of performance increased with the temperature of the generated cooling source. A decrease in the engine load resulted in a decrease in the exhaust flow rate and, consequently, in a decrease in the cooling capacity. Although the exhaust temperature reached its minimum around the normal continuous rating, the dependence of the cooling capacity on the engine load was not significantly affected. A case study for a liquefied natural gas carrier verified that the refrigeration system afforded a sufficient cooling capacity to satisfy both the required work and the temperature level needed for reliquefaction of the BOG.