Jun’iChi Kotoku

Jun’iChi Kotoku

Auto-generated profile, based on publicly available information

Jun’iChi Kotoku

Graduate School of Medical Care and Technology, Teikyo University, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2018 in Cureus
Verified
Journal Article
Open access
PDF file
SKSatoshi Kida
Satoshi Kida
TNTakahiro Nakamoto
Takahiro Nakamoto
MNMasahiro Nakano
Masahiro Nakano
KNKanabu Nawa
Kanabu Nawa
AHAkihiro Haga
Akihiro Haga
KNKeiichi Nakagawa
Keiichi Nakagawa
Cone beam computed tomography (CBCT) plays an important role in image-guided radiation therapy (IGRT), while having disadvantages of severe shading artifact caused by the reconstruction using scatter contaminated and truncated projections. The purpose of this study is to develop a deep convolutional neural network (DCNN) method for improving CBCT image quality. CBCT and planning computed tomography (pCT) image pairs from 20 prostate cancer patients were selected. Subsequently, each pCT volume was pre-aligned to the corresponding CBCT volume by image registration, thereby leading to registered pCT data (pCTr). Next, a 39-layer DCNN model was trained to learn a direct mapping from the CBCT to the corresponding pCTr images. The trained model was applied to a new CBCT data set to obtain improved CBCT (i-CBCT) images. The resulting i-CBCT images were compared to pCTr using the spatial non-uniformity (SNU), the peak-signal-to-noise ratio (PSNR) and the structural similarity index measure (SSIM). The image quality of the i-CBCT has shown a substantial improvement on spatial uniformity compared to that of the original CBCT, and a significant improvement on the PSNR and the SSIM compared to that of the original CBCT and the enhanced CBCT by the existing pCT-based correction method. We have developed a DCNN method for improving CBCT image quality. The proposed method may be directly applicable to CBCT images acquired by any commercial CBCT scanner.

19 June 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AOAsuka Oyama
Asuka Oyama
YHYasuaki Hiraoka
Yasuaki Hiraoka
IOIppei Obayashi
Ippei Obayashi
YSYusuke Saikawa
Yusuke Saikawa
SFShigeru Furui
Shigeru Furui
JKJun’iChi Kotoku
Jun’iChi Kotoku
The purpose of this study is to evaluate the accuracy for classification of hepatic tumors by characterization of T1-weighted magnetic resonance (MR) images using two radiomics approaches with machine learning models: texture analysis and topological data analysis using persistent homology. This study assessed non-contrast-enhanced fat-suppressed three-dimensional (3D) T1-weighted images of 150 hepatic tumors. The lesions included 50 hepatocellular carcinomas (HCCs), 50 metastatic tumors (MTs), and 50 hepatic hemangiomas (HHs) found respectively in 37, 23, and 33 patients. For classification, texture features were calculated, and also persistence images of three types (degree 0, degree 1 and degree 2) were obtained for each lesion from the 3D MR imaging data. We used three classification models. In the classification of HCC and MT (resp. HCC and HH, HH and MT), we obtained accuracy of 92% (resp. 90%, 73%) by texture analysis, and the highest accuracy of 85% (resp. 84%, 74%) when degree 1 (resp. degree 1, degree 2) persistence images were used. Our methods using texture analysis or topological data analysis allow for classification of the three hepatic tumors with considerable accuracy, and thus might be useful when applied for computer-aided diagnosis with MR images.

19 March 2020 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
TTTakumasa Tsuji
Takumasa Tsuji
YHYuta Hirose
Yuta Hirose
KFKohei Fujimori
Kohei Fujimori
THTakuya Hirose
Takuya Hirose
AOAsuka Oyama
Asuka Oyama
JKJun’ichi Kotoku
Jun’ichi Kotoku
Background: Classification of optical coherence tomography (OCT) images can be achieved with high accuracy using classical convolution neural networks (CNN), a commonly used deep learning network for computer-aided diagnosis. Classical CNN has often been criticized for suppressing positional relations in a pooling layer. Therefore, because capsule networks can learn positional information from images, we attempted application of a capsule network to OCT images to overcome that shortcoming. This study is our attempt to improve classification accuracy by replacing CNN with a capsule network. Methods: From an OCT dataset, we produced a training dataset of 83,484 images and a test dataset of 1000 images. For training, the dataset comprises 37,205 images with choroidal neovascularization (CNV), 11,348 with diabetic macular edema (DME), 8616 with drusen, and 26,315 normal images. The test dataset has 250 images from each category. The proposed model was constructed based on a capsule network for improving classification accuracy. It was trained using the training dataset. Subsequently, the test dataset was used to evaluate the trained model. Results: Classification of OCT images using our method achieved accuracy of 99.6%, which is 3.2 percentage points higher than that of other methods described in the literature. Conclusion: The proposed method achieved classification accuracy results equivalent to those reported for other methods for CNV, DME, drusen, and normal images.

30 March 2021 in Stem Cells
Verified
Journal Article
Open access
PDF file
THTakuya Hirose
Takuya Hirose
JKJun'IChi Kotoku
Jun'IChi Kotoku
FTFujio Toki
Fujio Toki
ENEmi K. Nishimura
Emi K. Nishimura
DNDaisuke Nanba
Daisuke Nanba
Stem cell-based products have clinical and industrial applications. Thus, there is a need to develop quality control methods to standardize stem cell manufacturing. Here, we report a deep learning-based automated cell tracking (DeepACT) technology for noninvasive quality control and identification of cultured human stem cells. The combination of deep learning-based cascading cell detection and Kalman filter algorithm-based tracking successfully tracked the individual cells within the densely packed human epidermal keratinocyte colonies in the phase-contrast images of the culture. DeepACT rapidly analyzed the motion of individual keratinocytes, which enabled the quantitative evaluation of keratinocyte dynamics in response to changes in culture conditions. Furthermore, DeepACT can distinguish keratinocyte stem cell colonies from non-stem cell-derived colonies by analyzing the spatial and velocity information of cells. This system can be widely applied to stem cell cultures used in regenerative medicine and provides a platform for developing reliable and noninvasive quality control technology.

5 April 2018 in Journal of Radiation Research
Verified
Journal Article
Open access
PDF file
AOAsuka Oyama
Asuka Oyama
SKShinobu Kumagai
Shinobu Kumagai
NANorikazu Arai
Norikazu Arai
TTTakeshi Takata
Takeshi Takata
YSYusuke Saikawa
Yusuke Saikawa
JKJun’iChi Kotoku
Jun’iChi Kotoku
This study was conducted to improve cone-beam computed tomography (CBCT) image quality using the super-resolution technique, a method of inferring a high-resolution image from a low-resolution image. This technique is used with two matrices, so-called dictionaries, constructed respectively from high-resolution and low-resolution image bases. For this study, a CBCT image, as a low-resolution image, is represented as a linear combination of atoms, the image bases in the low-resolution dictionary. The corresponding super-resolution image was inferred by multiplying the coefficients and the high-resolution dictionary atoms extracted from planning CT images. To evaluate the proposed method, we computed the root mean square error (RMSE) and structural similarity (SSIM). The resulting RMSE and SSIM between the super-resolution images and the planning CT images were, respectively, as much as 0.81 and 1.29 times better than those obtained without using the super-resolution technique. We used super-resolution technique to improve the CBCT image quality.

10 November 2017 in Journal of Radiation Research
Verified
Journal Article
Open access
PDF file
TTTakeshi Takata
Takeshi Takata
JKJun’iChi Kotoku
Jun’iChi Kotoku
HMHideyuki Maejima
Hideyuki Maejima
SKShinobu Kumagai
Shinobu Kumagai
NANorikazu Arai
Norikazu Arai
SFShigeru Furui
Shigeru Furui
To minimise the radiation dermatitis related to interventional radiology (IR), rapid and accurate dose estimation has been sought for all procedures. We propose a technique for estimating the patient skin dose rapidly and accurately using Monte Carlo (MC) simulation with a graphical processing unit (GPU, GTX 1080; Nvidia Corp.). The skin dose distribution is simulated based on an individual patient’s computed tomography (CT) dataset for fluoroscopic conditions after the CT dataset has been segmented into air, water and bone based on pixel values. The skin is assumed to be one layer at the outer surface of the body. Fluoroscopic conditions are obtained from a log file of a fluoroscopic examination. Estimating the absorbed skin dose distribution requires calibration of the dose simulated by our system. For this purpose, a linear function was used to approximate the relation between the simulated dose and the measured dose using radiophotoluminescence (RPL) glass dosimeters in a water-equivalent phantom. Differences of maximum skin dose between our system and the Particle and Heavy Ion Transport code System (PHITS) were as high as 6.1%. The relative statistical error (2 σ) for the simulated dose obtained using our system was ≤3.5%. Using a GPU, the simulation on the chest CT dataset aiming at the heart was within 3.49 s on average: the GPU is 122 times faster than a CPU (Core i7–7700K; Intel Corp.). Our system (using the GPU, the log file, and the CT dataset) estimated the skin dose more rapidly and more accurately than conventional methods.