14 April 2005 in European Heart Journal
Aims The 6-min walk test (6-MWT) is used to estimate functional capacity. However, in elderly patients with chronic heart failure (CHF): (i) 1 year reproducibility of the 6-MWT; (ii) sensitivity of the 6-MWT to self-perceived changes in symptoms of heart failure; and (iii) implications for patient numbers required for studies using the 6-MWT as an endpoint have not been described. Methods and results One thousand and seventy-seven patients with CHF, aged>60, with NYHA Class ≥II were recruited. Heart failure symptom assessment was determined using a questionnaire related to aspects of physical function, and patients performed a baseline 6-MWT, with follow-up 1 year later. Seventy-four patients with unchanged symptoms had an unchanged 6-MWT distance, with an overall intraclass correlation coefficient of 0.80 (95% CI=0.69–0.87). Four hundred and twenty-three patients reported an improvement in symptoms during follow-up. There was a negative correlation (r=−0.55; P=0.0001) between Δ symptoms and Δ 6-MWT (i.e. a reduced 6-MWT distance is associated with reduced symptom severity at follow-up). Five hundred and sixteen patients reported worsening symptoms of heart failure, a moderate inverse correlation (r=−0.53; P=0.0001) was displayed between Δ symptoms and Δ 6-MWT. For all patients, irrespective of symptom status, a high inverse correlation (r=−0.75; P=0.0001) was evident. On the basis of the data for patients with unchanged symptoms, it is calculated that to detect an increase in 6-MWT of 50 m, with 90% power, a study size of approximately 120 is required. Conclusion In elderly patients with CHF, the 6-MWT shows satisfactory agreement when repeated 1 year later. Change in 6-MWT distance is sensitive to change in self-perceived symptoms of heart failure.
1 June 2007 in International Journal of Cardiology
27 March 2014 in BioMed Research International
Background. The 6-minute walk test (6-MWT) is used to assess patients with chronic heart failure (CHF). The prognostic significance of the 6-MWT distance during long-term followup (>5 years) is unclear.Methods. 1,667 patients (median [inter-quartile range, IQR]) (age 72 [65–77]; 75% males) with heart failure due to left ventricular systolic impairment undertook a 6-MWT as part of their baseline assessment and were followed up for 5 years.Results. At 5 years’ followup, those patients who died (n= 959) were older at baseline and had a higher log NT pro-BNP than those who survived to 5 years (n= 708). 6-MWT distance was lower in those who died [163 (153) m versus 269 (160) m;P< 0.0001]. Median 6-MWT distance was 300 (150–376) m, and quartile ranges were 360 m. 6-MWT distance was a predictor of all-cause mortality (HR 0.97; 95% CI 0.96-0.97; Chi-square = 184.1;P< 0.0001). Independent predictors of all-cause mortality were decreasing 6-MWT distance, increasing age, increasing NYHA classification, increasing log NT pro-BNP, decreasing diastolic blood pressure, decreasing sodium, and increasing urea.Conclusion. The 6-MWT is an important independent predictor of all-cause mortality following long-term followup in patients with CHF.
1 May 2006 in European Journal of Heart Failure
Background: The clinical determinants of six-minute walk test (6-MWT) performance in patients with left ventricular systolic dysfunction (LVSD) have rarely been investigated, and it is not clear whether they differ from patients referred for the assessment of symptoms of heart failure who do not have major structural heart disease (MSHD). Methods and Results: 571 patients with LVSD enrolled in a chronic disease management programme (79% male; mean age 71±10 years; BMI 28±5) completed a 6-MWT with a mean distance 337±103 m. 688 patients referred with suspected heart failure but in whom MSHD was excluded (49% male; mean age 70±11 years; BMI 28±6) had a mean 6-MWT distance of 391±106 m (P300 m. In patients with LVSD, predictors of poor walking distance (≤300 m) included age ≥75 years (OR=4.0, 95% CI=2.4–6.4); low BMI (80 beats min−1 (OR=2.2, 95% CI=1.3–3.5); and being female (OR=2.0, 95% CI=1.3–3.0). Serum creatinine and NT-proBNP showed dose–response effects, as did self-perceived feelings of depression and anxiety. Determinants of 6-MWT in patients without MSHD were similar including age ≥75 years (OR=6.0, 95% CI=3.4–10.4), anaemia (OR=2.8, 95% CI=1.6–4.9), resting HR >80 beats min−1 (OR=2.5, 95% CI=1.4–4.4) and being female (OR=1.6, 95% CI=1.9–2.4). NT-proBNP and self-perceived feelings of depression and anxiety also showed dose–response effects. Conclusion: The determinants of poor 6-MWT performance depend on physical–cardiovascular and non-cardiovascular, and psychological factors. Clinical predictors for poor walking performance are similar for patients with LVSD and without MSHD.
1 June 2014 in Annals of Physical and Rehabilitation Medicine
1 April 2020 in International Journal of Cardiology
Recent evidence suggests that routine exercise-based cardiac rehabilitation (CR) may not lead to a substantial increase in estimated peak oxygen uptake (V̇O2peak). This could reduce the potential benefits of CR and explain why CR no longer improves patient survival in recent studies. We aimed to determine whether routine exercise-based CR increases V̇O2peak using gold-standard maximal cardiopulmonary exercise testing (CPET), and to quantify the exercise training stimulus which might be insufficient in patients undertaking CR. We studied the effects of a routine, twice weekly, exercise-based CR programme for eight weeks (intervention group) compared with abstention from supervised exercise training (control group) in patients with coronary heart disease. The primary outcome was V̇O2peak measured using CPET. We also measured changes in body composition using dual X-ray absorptiometry, carotid intima-media thickness, hs-CRP and N-terminal pro B-type natriuretic peptide at baseline, 10 weeks and 12 months. We also calculated the Calibre 5-year all-cause mortality risk score. Seventy patients (age 63.1 SD10.0 years; BMI 29.2 SD4.0 kg·m-2; 86% male) were recruited (n = 48 intervention; n = 22 controls). The mean aerobic exercise training duration was 23 min per training session, and the mean exercise training intensity was 45.9% of heart rate reserve. V̇O2peak was 23·3 ml·kg-1·min-1 at baseline, and there were no changes in V̇O2peak between groups at any time point. The intervention had no effect on any of the secondary endpoints. Routine CR does not lead to an increase in V̇O2peak and is unlikely to improve long-term physiological outcomes.