Thomas F. Higgins

Thomas F. Higgins

Auto-generated profile, based on publicly available information

Thomas F. Higgins

Department of Orthopaedic Surgery, University of Utah, Salt Lake City, Utah

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2013 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
PDF file
JHJoel E Holman
Joel E Holman
GSGregory J. Stoddard
Gregory J. Stoddard
THThomas F. Higgins
Thomas F. Higgins
Background: The prudent use of prescription opiate medications is a central aspect of postoperative pain management. The mortality associated with prescription opiate overdose is reaching epidemic proportions nationally, and is the leading cause of accidental death in greater than half the states in the United States. This study sought to determine the rates of preinjury opiate use in patients with orthopaedic trauma and the risk factors for prolonged use postinjury. Methods: The Utah Controlled Substance Database was queried to determine the use of prescription opiates by all patients admitted to the orthopaedic trauma service for a two-year period with isolated musculoskeletal injuries. Usage three months prior to injury and six months postinjury was examined. Results: Six hundred and thirteen patients met inclusion criteria. Among patients with orthopaedic trauma, 15.5% had filled a prescription for opiates in the three months prior to injury, compared with 9.2% of the general population (p < 0.001). More than one prescription was filled by 12.2% of the patients with trauma preinjury compared with 6.4% of the general population (p < 0.001). Postoperatively, 68.4% of all patients filled opiate prescriptions for less than six weeks, 11.9% filled opiate prescriptions between six and twelve weeks, and 19.7% filled opiate prescriptions past twelve weeks. Patients with preinjury use of more than one opiate prescription in the three months preinjury were six times as likely to continue use past twelve weeks, and 3.5 times as likely to obtain opiates from a provider other than their surgeon (p < 0.001). Opiate use was briefest with upper-extremity injuries, followed by lower-extremity injuries and pelvic or acetabular injuries. Regression models demonstrate that risk factors for prolonged use of opiates include advancing age and extent of preinjury use. Conclusions: Patients with orthopaedic trauma are significantly more likely than the general population to use prescription opiates prior to injury. Preinjury opiate use is predictive of prolonged use postinjury and predictive of patients who will seek opiates from other providers. Level of Evidence: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

1 April 2010 in Orthopedic Clinics of North America
Verified
Journal Article
Closed access
THThomas F. Higgins
Thomas F. Higgins
JKJoshua B. Klatt
Joshua B. Klatt
TBTimothy C. Beals
Timothy C. Beals

1 January 2009 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
THThomas F Higgins
Thomas F Higgins
DKDan Kemper
Dan Kemper
JKJoshua Klatt
Joshua Klatt
Bicondylar tibial plateau fractures featuring extensive articular involvement have a record of mixed clinical results. Recent discussion has focused on the significance of a posteromedial articular fragment in bicondylar injuries. This fragment has often gone unrecognized or has not been addressed. The posteromedial fragment is defined as any posteriorly based articular fracture of the medial plateau with the fracture line exiting the medial cortex. This study is designed to produce a detailed description of the incidence, size, and shape of this fracture, as this may be helpful in driving the choice of both approach and fixation for these injuries. Furthermore, a better understanding of this fracture's morphology may lead to a better ability to model the biomechanical reliability of laterally based locking fixation in securing the reduction of this fracture fragment. Retrospective study of patient records and computed tomography scans. Level I university regional trauma center. All patients treated for bicondylar tibial plateau fracture from January 1, 2002, through August 31, 2007. One hundred forty-eight patients were identified in the 5.5-year period, and 111 had complete computed tomography records (75%). Of 111 bicondylar tibial plateau fractures analyzed, this fragment occurred in 65 cases (59% incidence) and on average accounted for 25% of the total tibial plateau joint surface. There was greater than 5 mm of articular displacement in 55% of cases. The posteromedial fragment exhibits a vertical fracture pattern (average sagittal angle 73 degrees), suggestive of shear instability and vertical displacement. Given the high frequency, significant portion of the joint involved, significant displacement, and pattern suggestive of instability, surgeons need to be cognizant of this pattern and may need to consider directly reducing and fixating this fragment through a posteromedially based approach. Overall morphologic findings of the posteromedial fragment are highly consistent with other recent data on this pattern. This information may also be useful in modeling fracture fixation for future study.

1 January 2007 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
THThomas F Higgins
Thomas F Higgins
GPGavin Pittman
Gavin Pittman
JHJerod Hines
Jerod Hines
KBKent N Bachus
Kent N Bachus
Objective: The objective of this study is to establish the relative strength of fixation of a locking distal femoral plate compared with the condylar blade plate. Methods: Eight matched pairs of fresh-frozen cadaveric femurs were selected and evaluated for bone density. A gap osteotomy model was used to simulate an OTA/AO A3 comminuted distal femur fracture. One femur of each pair was fixed with the blade plate; the other, with a locking plate. After 100 N preload and 10,000 cycles between 100 N and 1000 N, total displacement of each specimen was assessed. After completion of cyclic loading, maximum load to failure was tested. Results: Significantly greater subsidence (total axial displacement) occurred with the blade plate (1.70 ± 0.45 mm; range, 1.21-2.48 mm) than with the locking plate fixation (1.04 ± 0.33 mm; range, 0.67-1.60 mm) after cyclic loading (P = 0.03). In load-to-failure testing, force absorbed by the locking plate before failure (9085 ± 1585 N; range, 7269-11,850 N) was significantly greater than the load tolerated by the blade plate construct (5591 ± 945 N; range, 3546-6684 N; P = 0.001). Variability in bone mineral density did not affect the findings (fixed angle distal femoral plate r2 = 0.1563; condylar blade plate r2 = 0.0796). Conclusions: The locking screw-plate construct proved stronger than the blade plate in both cyclic loading and ultimate strength in biomechanical testing of a simulated A3 distal femur fracture. Although differences were small, the biomechanical performance of the locking plate construct over the blade plate may lend credence to use of the locking plate versus the blade plate in the fixation of comminuted distal femur fractures.

1 March 2007 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
THThomas F Higgins
Thomas F Higgins
VCVirginia Casey
Virginia Casey
KBKent Bachus
Kent Bachus
Objective: To compare the heat generation and pressure generation of a prototype irrigating aspirating intramedullary reaming system to traditional stepwise reaming. Design: This in vitro study used 8 pairs of fresh-frozen human cadaver tibias. Thermocouples were mounted in the mid-diaphysis and distal diaphysis. A pressure transducer was placed distally to assess intramedullary pressure, a load cell measured axial load was applied by the surgeon, and the entire construct was placed in a 37°C saline bath. One specimen from each pair underwent single-pass reaming with the prototype reamer irrigator aspirator (RIA), and the contralateral limb underwent standard stepwise reaming. All variables were recorded. Results: There were no significant differences in pressure applied to the load cells during reaming. The maximum temperatures reached in the distal diaphysis in the RIA group (42.0 ± 9.1°C) were significantly lower (P = 0.025) than in the standard reaming group (58.7 ± 15.9°C). The maximum pressure generated in the distal tibia in the RIA group (32.7 ± 39.4 kPa) was significantly higher (P = 0.019) than in the standard reaming group (17.0 ± 32.6 kPa). Conclusions: This study demonstrated substantially decreased temperatures with the RIA prototype when compared with standard stepwise reaming. It appears that the continuous flow of room temperature saline irrigant into the system manages to cool the cortical bone, despite the aggressive nature of a single-pass reaming method. However, in this model, contrary to the findings of other studies, the RIA system did generate higher pressures in the distal tibial metaphysis, perhaps as a result of congestion within the outflow of the RIA system. The results of this study confirm that cortical heat generation is not a problem but definitely indicate further development of this prototype aspirator function is warranted, followed by careful in vivo evaluation.

1 November 2015 in Injury
Verified
Journal Article
Closed access
JHJustin M. Haller
Justin M. Haller
RORobert O’tOole
Robert O’tOole
MGMatthew Graves
Matthew Graves
DBDavid Barei
David Barei
MGMichael Gardner
Michael Gardner
THThomas F. Higgins
Thomas F. Higgins