24 September 2012 in The Laryngoscope
1 January 2010 in Plastic and Reconstructive Surgery
The anterolateral thigh free flap may be harvested as a fasciocutaneous perforator flap or as a myocutaneous flap by including variable amounts of the vastus lateralis muscle. The authors sought to determine the donor-site morbidity associated with both types of flap dissection. Between 2005 and 2008, the authors performed 220 reconstructive operations using the anterolateral thigh free flap. Complications and donor-site function were evaluated prospectively. Variable amounts of vastus lateralis muscle were harvested with the flap in this series: 25 percent included no muscle, 38 percent included minimal muscle, 33 percent included the superficial half of the muscle, and 4 percent included the entire muscle. The motor nerve to the vastus lateralis muscle was spared during dissection of the flap pedicle in 78 percent but required division in 22 percent. Complications included seroma (5 percent), wound dehiscence (2 percent), hematoma (1 percent), infection (1 percent), neuroma (1 percent), and partial skin graft loss (1 percent). Eighty-four percent of patients reported a sensory loss in the distribution of the lateral femoral cutaneous nerve. Weakness or instability was reported by 8 percent of patients at their initial postoperative visit but resolved in all patients within 6 months. All patients regained their postoperative level of activity. The anterolateral thigh free flap is associated with a low rate of complications and functional morbidity. Even when the motor nerve to the vastus lateralis is divided, or substantial amounts of thigh fascia or vastus lateralis muscle are included in the flap design, all patients return to their preoperative level of function.
15 June 2010 in Head & Neck
1 January 2009 in Plastic and Reconstructive Surgery
The authors' goal was to describe an algorithm for surgical reconstruction and prosthetic rehabilitation after orbital exenteration. A review of 79 patients who underwent orbital exenteration between 1999 and 2007 was performed. Reconstructions were classified as resulting in an "open" cavity when a concave orbital socket facilitating prosthetic retention was created or a "closed" cavity when the orbit was filled with soft tissue to the level of the orbital rim. Reconstructive procedures included skin grafts (n = 18), regional flaps (n = 6), and microvascular free flaps (n = 55). Open cavities were created in 34 patients and closed cavities were created in 45 patients. Twenty-one patients (27 percent) experienced surgical complications. There were no significant differences in complication rates among various reconstructive techniques (skin graft versus regional flap versus free flap) or types of cavities created (open versus closed). Of the 17 patients who use prostheses, eight (47 percent) wear their prostheses regularly. Fourteen patients (82 percent) who received an orbital prosthesis had open cavities (p = 0.001). Thirty-nine percent of patients with a skin graft received orbital prostheses, and 17 percent with a regional flap and 15 percent with a free flap received orbital prostheses (p = 0.01). The reconstructive method should be tailored to the defect and the patient's needs. When a prosthetic is planned, the goal should be to create an open cavity with a skin graft, regional flap, or thin free flap. Bulky free flaps are indicated when a closed cavity is preferred, such as when no prosthetic is planned or the defect is extensive.
1 June 2009 in Annals of Plastic Surgery
Despite the development of multiple cranial bone substitutes, calvarial reconstruction remains a significant challenge. Although autologous bone is preferred in many cases, its usefulness may be limited by difficulty with contouring, resorption, and donor site availability and morbidity. Alloplastic cranioplasties are also widely used with each material having its advantages and disadvantages. Computer-designed implants have the advantages of minimizing operative time for preparation, shaping, and insetting. We report our initial clinical experience in 6 patients with computer-designed, prefabricated polyetheretherketone implants, which may have significant advantages over other alloplastic materials in terms of strength, stiffness, durability, thermal conductivity, and radiographic translucency.
1 November 2010 in Plastic and Reconstructive Surgery
Background: The authors' goal was to determine whether one or two venous anastomoses results in superior blood flow through microvascular free flaps. Methods: During flap harvest, blood velocity was measured in each of two venae comitantes using Doppler ultrasonography. Next, one of the two veins was occluded with a microvascular clamp and blood velocity was measured in the open vein. The clamp was then removed and placed on the other vein, and blood velocity was measured in the first vein. The pedicle was divided and microvascular anastomosis of either one or two veins was performed. Venous blood velocity was then compared between flaps with one versus two venous anastomoses. Results: Eighty-one free flaps were performed. Before pedicle division, the peak venous blood velocity in each of the two venae comitantes averaged 6.3 ± 4.8 cm/second. When one of the veins was occluded, the peak venous blood velocity increased to 19.5 ± 17.3 cm/second (p < 0.00001). One venous anastomosis was performed in 69 flaps and two venous anastomoses were performed in 12 flaps. The mean blood velocity in flaps in which one venous anastomosis was performed was greater than the mean blood velocity in either vein when two venous anastomoses were performed (13.1 ± 7.3 cm/second versus 7.5 ± 4.3 cm/second, respectively; p = 0.001). Conclusions: When one vena comitans is occluded, blood velocity in the second vena comitans increases significantly. Venous blood velocity is significantly greater after a single venous anastomosis than in either of two veins when two venous anastomoses are performed. These results argue against routinely performing two venous anastomoses.