Titanium is a primary metallic biomaterial used in load-bearing orthopedic or dental implants because of its favorable mechanical properties and osseointegration capability. This article reviews the current status of surface optimization techniques for titanium implants, whether such concepts are in the form of sufficiently evidence-based, and highlights the related experimental tools. A strong emphasis was placed on the enhanced biological responses to titanium implants by modifying the surface finishing process. On this basis, a clear partition of surface chemistry and topography was critical. The intrinsic host tissue response to titanium implants is facilitated by the chemistry or topography of a passive oxide film, although the extent to which the surface characteristics enable rapid osseointegration is still uncertain. Besides the fundamental requirements, such as the promotion of osteogenic differentiation, the titanium implant surface should accelerate wound-healing phenomena prior to bone ingrowth toward the surface. Moreover, because initial bacterial attachment to the implant surface is unavoidable, infection control by surface modification is also an important determinant in reducing surgical failure. A desirable surface-biological relationship often needs to be characterized at the nanoscale by means of advanced technologies.
The purpose of this article is to review the mechanical requirements of the tissue-implant interface and analyze related theories. The osseointegration capacity of titanium implants has been investigated over the past 50 years. We considered the ultimate goal of osseointegration to which form a desirable interfacial layer and a bone matrix with adequate biomechanical properties. Occasionally, the interface comprises porous titanium and bone ingrowth that enables a functionally graded Young's modulus, thereby allowing reduction of stress shielding. However, the optimal biomechanical connection at the interface has not yet been fully clarified. There have been publications supporting several universal mechanical testing technologies in terms of bone-titanium bonding ability, although the separation of newly formed bone quality is unlikely. The understanding of complex mechanical bone behavior and size-dependent properties ranging from a nano- to a macroscopic level are essential in the biomechanical optimization of implants. The requirements of regenerated tissue at the interface include high strength, fracture toughness related to ductility, and time-dependent energy dissipation and/or elastic-plastic stress distribution. Moreover, a strong relationship between strain signals and peri-implant tissue turnover could be expected, so that ideal implant biomechanics may enable longevity via adaptive bone remodeling.
Reconstitution of carious dentin has been recognized as difficult, because it progresses by loss of collagen polymerization and by demineralization under acidic conditions. Recently, colloidal alkaline nano-calcium phosphate, prepared by electrical discharge in a buffered physiological saline solution, has been shown to be effective in the formulation of a bone-like biocomposite by simply being mixed with acidic collagen solution. It was hypothesized that colloidal calcium phosphate was suitable for the reconstitution of carious dentin. Natural caries lesions in dentin from permanent teeth were exposed to colloidal hydroxyapatite and β-tricalcium phosphate for 10 days. The micromechanical properties of these tissues were evaluated by nano-indentation. The elastic modulus of human carious dentin improved after samples were immersed in colloidal β-tricalcium phosphate. The mineral density of carious dentin exposed to β-tricalcium phosphate increased more than that immersed in hydroxyapatite. However, since it was not directly proportional to micromechanical recovery, mineral density alone was not a sufficient indicator of mechanical behavior.
Glow discharge plasma (GDP) supplied to a cathode (GDP-) has been applied for cleaning, surface activating, and sterilizing biomaterials, because the kinetic energy in the case of the GDP- is larger than that supplied to the anode (GDP+). However, no comparison between GDP+ and GDP- has been reported. In this study, a titanium surface pre-treated with GDP+ and GDP- was characterized by x-ray photoelectron spectroscopy (XPS). In addition, the wettability of the titanium surface was measured with and without GDP. Furthermore, XPS characterized the adsorption of inorganic ions on titanium surfaces with and without GDP and immersed in an electrolyte solution. The findings suggested that GDP+ enhances calcium phosphate nucleation, due to the accumulation of electrons. In addition, calcium phosphate was not nucleated on the specimen with GDP-. We conclude that GDP+ is more suitable for biomineralization on titanium.
Aims: Osteoarthritis (OA) is a common degenerative joint disease. The osteocyte transcriptome is highly relevant to osteocyte biology. This study aimed to explore the osteocyte transcriptome in subchondral bone affected by OA. Methods: Gene expression profiles of OA subchondral bone were used to identify disease-relevant genes and signalling pathways. RNA-sequencing data of a bone loading model were used to identify the loading-responsive gene set. Weighted gene co-expression network analysis (WGCNA) was employed to develop the osteocyte mechanics-responsive gene signature. Results: A group of 77 persistent genes that are highly relevant to extracellular matrix (ECM) biology and bone remodelling signalling were identified in OA subchondral lesions. A loading responsive gene set, including 446 principal genes, was highly enriched in OA medial tibial plateaus compared to lateral tibial plateaus. Of this gene set, a total of 223 genes were identified as the main contributors that were strongly associated with osteocyte functions and signalling pathways, such as ECM modelling, axon guidance, Hippo, Wnt, and transforming growth factor beta (TGF-β) signalling pathways. We limited the loading-responsive genes obtained via the osteocyte transcriptome signature to identify a subgroup of genes that are highly relevant to osteocytes, as the mechanics-responsive osteocyte signature in OA. Based on WGCNA, we found that this signature was highly co-expressed and identified three clusters, including early, late, and persistently responsive genes. Conclusion: In this study, we identified the mechanics-responsive osteocyte signature in OA-lesioned subchondral bone. Cite this article: Bone Joint Res 2022;11(6):362–370.