20 September 2007 in Analytical Chemistry
1 April 2013 in Review of Scientific Instruments
A novel ultra-high vacuum instrument for X-ray reflectometry and spectrometry-related techniques for nanoanalytics by means of synchrotron radiation has been constructed and commissioned. This versatile instrument was developed by the Physikalisch-Technische Bundesanstalt, Germany's national metrology institute, and includes a 9-axis manipulator that allows for an independent alignment of the samples with respect to all degrees of freedom. In addition, a rotational and translational movement of several photodiodes as well as a translational movement of an aperture system in and out of the beam is provided. Thus, the new instrument enables various analytical techniques based on energy dispersive X-ray detectors such as reference-free X-ray fluorescence analysis (XRF), total-reflection XRF, grazing-incidence XRF in addition to optional X-ray reflectometry measurements or polarization-dependent X-ray absorption fine structure analyses. With this instrument samples having a size of up to 100 mm × 100 mm can be analyzed with respect to their mass deposition, elemental or spatial composition, or the species in order to probe surface contamination, layer composition and thickness, the depth profile of matrix elements or implants, the species of nanolayers, nanoparticles or buried interfaces as well as the molecular orientation of bonds. Selected applications of this advanced ultra-high vacuum instrument demonstrate both its flexibility and capability.
10 August 2017 in Metrologia
19 October 2012 in Physical Review A
Photon-in/photon-out experiments at thin specimens have been carried out to determine -subshell fluorescence yields as well as Coster-Kronig transition probabilities of Au, Pb, Mo, and Pd using radiometrically calibrated instrumentation in the Physikalisch-Technische Bundesanstalt (PTB) laboratory at the electron storage ring BESSY II in Berlin. An advanced approach was developed in order to derive the fluorescence line intensities by means of line sets of each subshell that were corrected for self-absorption and broadened with experimentally determined detector response functions. The respective photoelectric cross sections for each subshell were determined by means of transmission measurements of the same samples without any change in the experimental operating condition. All values derived were compared to those of earlier works. A completely traceable uncertainty budget is provided for the determined values.
5 July 2006 in Physical Review A
We studied the resonant Raman scattering of x rays in the vicinity of the absorption edge of silicon. The investigation was carried out at the plane grating monochromator beamline for undulator radiation of the PTB laboratory at BESSY II in Berlin. Cross sections were determined absolutely for a wide energy range of incident photons with small relative uncertainties employing calibrated instrumentation avoiding any reference samples. The experimentally determined values differ clearly from the theoretical ones found in the literature.