Sönke Langner

Sönke Langner

Auto-generated profile, based on publicly available information

Sönke Langner

Institute and Policlinic of Radiology, Paediatric Radiology and Neuroradiology, Rostock University Medical Centre, Rostock, Germany

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2017 in Journal of Clinical Investigation
Verified
Journal Article
Open access
PDF file
HJHana Janova
Hana Janova
SASahab Arinrad
Sahab Arinrad
EBEvan Balmuth
Evan Balmuth
MMMarina Mitjans
Marina Mitjans
JHJohannes Hertel
Johannes Hertel
KNKlaus Nave
Klaus Nave
The underlying cellular mechanisms of catatonia, an executive “psychomotor” syndrome that is observed across neuropsychiatric diseases, have remained obscure. In humans and mice, reduced expression of the structural myelin protein CNP is associated with catatonic signs in an age-dependent manner, pointing to the involvement of myelin-producing oligodendrocytes. Here, we showed that the underlying cause of catatonic signs is the low-grade inflammation of white matter tracts, which marks a final common pathway in Cnp-deficient and other mutant mice with minor myelin abnormalities. The inhibitor of CSF1 receptor kinase signaling PLX5622 depleted microglia and alleviated the catatonic symptoms of Cnp mutants. Thus, microglia and low-grade inflammation of myelinated tracts emerged as the trigger of a previously unexplained mental condition. We observed a very high (25%) prevalence of individuals with catatonic signs in a deeply phenotyped schizophrenia sample (n = 1095). Additionally, we found the loss-of-function allele of a myelin-specific gene (CNP rs2070106-AA) associated with catatonia in 2 independent schizophrenia cohorts and also associated with white matter hyperintensities in a general population sample. Since the catatonic syndrome is likely a surrogate marker for other executive function defects, we suggest that microglia-directed therapies may be considered in psychiatric disorders associated with myelin abnormalities.

4 June 2008 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
SLS. Langner
S. Langner
SSS. Stumpe
S. Stumpe
MKM. Kirsch
M. Kirsch
MPM. Petrik
M. Petrik
NHN. Hosten
N. Hosten
BACKGROUND AND PURPOSE: Contrast-induced nephropathy (CIN) is one of the most common causes of in-hospital acute renal failure. The aim of this study was to assess the risk for CIN after repeated administration of the nonionic, dimeric, iso-osmolal contrast agent iodixanol regardless of pre-existing renal function. Changes in serum creatinine (SCr) levels were compared with those of control subjects who did not receive iodinated contrast media (CM).

13 August 2010 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
ILInga Langner
Inga Langner
MFMatthias Frank
Matthias Frank
JKJens Peter Kuehn
Jens Peter Kuehn
PHPeter Hinz
Peter Hinz
AEAxel Ekkernkamp
Axel Ekkernkamp
SLSoenke Langner
Soenke Langner

1 May 2014 in Investigative Radiology
Verified
Journal Article
Closed access
AGAndreas Graessl
Andreas Graessl
MMMaximilian B.Eng. Muhle
Maximilian B.Eng. Muhle
MSMichael Schwerter
Michael Schwerter
JRJan Msc Rieger
Jan Msc Rieger
COCelal Oezerdem
Celal Oezerdem
Thoralf NiendorfThoralf Niendorf
Thoralf Niendorf
Objectives This study was designed to examine the feasibility of ophthalmic magnetic resonance imaging (MRI) at 7 T using a local 6-channel transmit/receive radiofrequency (RF) coil array in healthy volunteers and patients with intraocular masses. Materials and Methods A novel 6-element transceiver RF coil array that makes uses of loop elements and that is customized for eye imaging at 7 T is proposed. Considerations influencing the RF coil design and the characteristics of the proposed RF coil array are presented. Numerical electromagnetic field simulations were conducted to enhance the RF coil characteristics. Specific absorption rate simulations and a thorough assessment of RF power deposition were performed to meet the safety requirements. Phantom experiments were carried out to validate the electromagnetic field simulations and to assess the real performance of the proposed transceiver array. Certified approval for clinical studies was provided by a local notified body before the in vivo studies. The suitability of the RF coil to image the human eye, optical nerve, and orbit was examined in an in vivo feasibility study including (a) 3-dimensional (3D) gradient echo (GRE) imaging, (b) inversion recovery 3D GRE imaging, and (c) 2D T2-weighted fast spin-echo imaging. For this purpose, healthy adult volunteers (n = 17; mean age, 34 ± 11 years) and patients with intraocular masses (uveal melanoma, n = 5; mean age, 57 ± 6 years) were investigated. Results All subjects tolerated all examinations well with no relevant adverse events. The 6-channel coil array supports high-resolution 3D GRE imaging with a spatial resolution as good as 0.2 × 0.2 × 1.0 mm3, which facilitates the depiction of anatomical details of the eye. Rather, uniform signal intensity across the eye was found. A mean signal-to-noise ratio of approximately 35 was found for the lens, whereas the vitreous humor showed a signal-to-noise ratio of approximately 30. The lens-vitreous humor contrast-to-noise ratio was 8, which allows good differentiation between the lens and the vitreous compartment. Inversion recovery prepared 3D GRE imaging using a spatial resolution of 0.4 × 0.4 × 1.0 mm3 was found to be feasible. T2-weighted 2D fast spin-echo imaging with the proposed RF coil afforded a spatial resolution of 0.25 × 0.25 × 0.7 mm3. Conclusions This work provides valuable information on the feasibility of ophthalmic MRI at 7 T using a dedicated 6-channel transceiver coil array that supports the acquisition of high-contrast, high–spatial resolution images in healthy volunteers and patients with intraocular masses. The results underscore the challenges of ocular imaging at 7 T and demonstrate that these issues can be offset by using tailored RF coil hardware. The benefits of such improvements would be in positive alignment with explorations that are designed to examine the potential of MRI for the assessment of spatial arrangements of the eye segments and their masses with the ultimate goal to provide imaging means for guiding treatment decisions in ophthalmological diseases.

24 March 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
MWMatthias Wilms
Matthias Wilms
JBJordan Bannister
Jordan Bannister
PMPauline Mouches
Pauline Mouches
MMM. Ethan MacDonald
M. Ethan MacDonald
DRDeepthi Rajashekar
Deepthi Rajashekar
NFNils Daniel Forkert
Nils Daniel Forkert
Many machine learning tasks in neuroimaging aim at modeling complex relationships between a brain’s morphology as seen in structural MR images and clinical scores and variables of interest. A frequently modeled process is healthy brain aging for which many image-based brain age estimation or age-conditioned brain morphology template generation approaches exist. While age estimation is a regression task, template generation is related to generative modeling. Both tasks can be seen as inverse directions of the same relationship between brain morphology and age. However, this view is rarely exploited and most existing approaches train separate models for each direction. In this paper, we propose a novel bidirectional approach that unifies score regression and generative morphology modeling and we use it to build a bidirectional brain aging model. We achieve this by defining an invertible normalizing flow architecture that learns a probability distribution of 3D brain morphology conditioned on age. The use of full 3D brain data is achieved by deriving a manifold-constrained formulation that models morphology variations within a low-dimensional subspace of diffeomorphic transformations. This modeling idea is evaluated on a database of MR scans of more than 5000 subjects. The evaluation results show that our bidirectional brain aging model (1) accurately estimates brain age, (2) is able to visually explain its decisions through attribution maps and counterfactuals, (3) generates realistic age-specific brain morphology templates, (4) supports the analysis of morphological variations, and (5) can be utilized for subject-specific brain aging simulation.

28 June 2019 in Acta Neurochirurgica
Verified
Journal Article
Closed access
PDF file
CHChristian Henker
Christian Henker
MHMarie Cristin Hiepel
Marie Cristin Hiepel
TKThomas Kriesen
Thomas Kriesen
MSMoritz Scherer
Moritz Scherer
ÄGÄnne Glass
Änne Glass
JPJürgen Piek
Jürgen Piek