Bret. W. Butler

Bret. W. Butler

Auto-generated profile, based on publicly available information

Bret. W. Butler

US Forest Service

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2012 in International Journal of Wildland Fire
Verified
Journal Article
Closed access
PDF file
DFDavid Frankman
David Frankman
BWBrent W. Webb
Brent W. Webb
BBBret W. Butler
Bret W. Butler
DJDaniel Jimenez
Daniel Jimenez
JFJason M. Forthofer
Jason M. Forthofer
RORoger D. Ottmar
Roger D. Ottmar
Time-resolved irradiance and convective heating and cooling of fast-response thermopile sensors were measured in 13 natural and prescribed wildland fires under a variety of fuel and ambient conditions. It was shown that a sensor exposed to the fire environment was subject to rapid fluctuations of convective transfer whereas irradiance measured by a windowed sensor was much less variable in time, increasing nearly monotonically with the approach of the flame front and largely declining with its passage. Irradiance beneath two crown fires peaked at 200 and 300 kW m–2, peak irradiance associated with fires in surface fuels reached 100 kW m–2 and the peak for three instances of burning in shrub fuels was 132 kW m–2. The fire radiative energy accounted for 79% of the variance in fuel consumption. Convective heating at the sensor surface varied from 15% to values exceeding the radiative flux. Detailed measurements of convective and radiative heating rates in wildland fires are presented. Results indicate that the relative contribution of each to total energy release is dependent on fuel and environment.

24 March 2014 in International Journal of Wildland Fire
Verified
Journal Article
Closed access
PDF file
BBB. W. Butler
B. W. Butler
Current wildland firefighter safety zone guidelines are based on studies that assume flat terrain, radiant heating, finite flame width, constant flame temperature and high flame emissivity. Firefighter entrapments and injuries occur across a broad range of vegetation, terrain and atmospheric conditions generally when they are within two flame heights of the fire. Injury is not confined to radiant heating or flat terrain; consequently, convective heating should be considered as a potential heating mode. Current understanding of energy transport in wildland fires is briefly summarised, followed by an analysis of burn injury mechanisms within the context of wildland fire safety zones. Safety zone theoretical and experimental studies are reviewed and a selection of wildland fire entrapments are examined within the context of safe separation distances from fires. Recommendations are made for future studies needed to more fully understand and define wildland firefighter safety zones.

13 May 2010 in International Journal of Wildland Fire
Verified
Journal Article
Closed access
PDF file
WAW. R. Anderson
W. R. Anderson
ECE. A. Catchpole
E. A. Catchpole
BBB. W. Butler
B. W. Butler
An extensive set of wind-tunnel fires was burned to investigate convective heat transfer ahead of a steadily progressing fire front moving across a porous fuel bed. The effects of fuel and environmental variables on the gas temperature profile and the ‘surface wind speed’ (gas velocity at the fuel bed surface) are reported. In non-zero winds, the temperature of the air near the fuel bed surface decays exponentially with distance from the fire front. In zero winds, the temperature decreases rapidly within a very short distance of the flame front, then decays slowly thereafter. The maximum air temperature decreases as the free stream wind speed, packing ratio and fuel moisture content increase. The characteristic distance of the exponential decay increases strongly with the free stream wind speed and decreases with the packing ratio and surface area-to-volume ratio of the fuel. The surface wind speed depends strongly on the free stream wind speed, and to a lesser extent on packing ratio, fuel bed depth and fuel moisture content. There are three general regimes for the surface flow: (1) a constant velocity flow of approximately half the free stream flow, far from the flame front; (2) an intermediate zone of minimum flow characterised by low or reversed flow; and (3) a region near the flame front where the velocity rises rapidly almost to the free stream velocity. The boundaries between the three regions move further from the flame front with increasing wind speed, in a way which is only slightly affected by fuel geometry.

1 January 1998
Verified
Report
Open access
PDF file
BBBret W. Butler
Bret W. Butler
RBRoberta A. Bartlette
Roberta A. Bartlette
LBLarry S. Bradshaw
Larry S. Bradshaw
JCJack D. Cohen
Jack D. Cohen
PAPatricia L. Andrews
Patricia L. Andrews
RMRichard J. Mangan
Richard J. Mangan

8 August 2017 in International Journal of Wildland Fire
Verified
Journal Article
Open access
PDF file
WPWesley Page
Wesley Page
BBBret W. Butler
Bret W. Butler
Wildland firefighters in the US are mandated to identify areas that provide adequate separation between themselves and the flames (i.e. safety zones) to reduce the risk of burn injury. This study presents empirical models that estimate the distance from flames that would result in a low probability (1 or 5%) of either fatal or non-fatal injuries. The significant variables for the fatal injury model were fire shelter use, slope steepness and flame height. The separation distances needed to ensure no more than a 1 or 5% probability of fatal injury, without the use of a fire shelter, for slopes less than 25% were 20 to 50 m for flame heights less than 10 m, and 1 to 4 times the flame height for flames taller than 10 m. The non-fatal injury model significant variables were fire shelter use, vehicle use and fuel type. At the 1 and 5% probability thresholds for a non-fatal injury, without the use of a fire shelter, the separation distances were 1 to 2, 6 to 7, and 12 to 16 times greater than the current safety zone guideline (i.e. 4 times the flame height) for timber, brush and grass fuel types respectively.

15 December 2015 in International Journal of Wildland Fire
Verified
Journal Article
Closed access
PDF file
BBB. Butler
B. Butler
CTC. Teske
C. Teske
DJD. Jimenez
D. Jimenez
JOJ. O’brien
J. O’brien
PSP. Sopko
P. Sopko
ELE. Loudermilk
E. Loudermilk
Wildland fire rate of spread (ROS) and intensity are determined by the mode and magnitude of energy transport from the flames to the unburned fuels. Measurements of radiant and convective heating and cooling from experimental fires are reported here. Sensors were located nominally 0.5 m above ground level. Flame heights varied from 0.3 to 1.8 m and flaming zone depth varied from 0.3 to 3.0 m. Fire ROS derived from observations of fire transit time between sensors was 0.10 to 0.48 m s–1. ROS derived from ocular estimates reached 0.51 m s–1 for heading fire and 0.25 m s–1 for backing fire. Measurements of peak radiant and total energy incident on the sensors during flame presence reached 18.8 and 36.7 kW m–2 respectively. Peak air temperatures reached 1159°C. Calculated fire radiative energy varied from 7 to 162 kJ m–2 and fire total energy varied from 3 to 261 kJ m–2. Measurements of flame emissive power peaked at 95 kW m–2. Average horizontal air flow in the direction of flame spread immediately before, during, and shortly after the flame arrival reached 8.8 m s–1, with reverse drafts of 1.5 m s–1; vertical velocities varied from 9.9 m s–1 upward flow to 4.5 m s–1 downward flow. The observations from these fires contribute to the overall understanding of energy transport in wildland fires.