Klaus Mönkemüller

Klaus Mönkemüller

Auto-generated profile, based on publicly available information

Klaus Mönkemüller

Department of Gastroenterology, Hepatology and Infectious Diseases, Otto-von-Guericke University, Magdeburg, Germany

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2006 in Endoscopy
Verified
Journal Article
Closed access
PDF file
KMK. Mönkemüller
K. Mönkemüller
JWJ. Weigt
J. Weigt
GTG. Treiber
G. Treiber
SKS. Kolfenbach
S. Kolfenbach
SKS. Kahl
S. Kahl
PMP. Malfertheiner
P. Malfertheiner
Background and Study Aims: Double-balloon enteroscopy (DBE) is a new endoscopic method for examining the small intestine. Most reports of DBE have been from Japan, and very few data on this new technique have been reported by centers outside Japan. The aim of the present study was to determine the diagnostic yield of DBE, measure the frequency of management changes made on the basis of the results, and evaluate the clinical outcome for patients undergoing the procedure. Patients and Methods: All patients undergoing DBE using a Fujinon enteroscope (length 200 cm, diameter 8 mm) during a 11-month period were studied. All of the patients had previously undergone esophagogastroduodenoscopy and colonoscopy. They underwent small-bowel cleansing on the day before the procedure using a standard colon lavage solution. Results: Seventy DBE procedures were carried out in 53 patients (34 men, 19 women; mean age 60 years, range 24 - 80) by the oral route in 46 cases and the anal route in 24. The indications for the examination were gastrointestinal bleeding (n = 29), suspected Crohn’s disease (n = 6), abdominal pain (n = 4), polyp removal or evaluation in polyposis syndromes (n = 6), chronic diarrhea (n = 4), and surveillance or tumor search (n = 4). The mean duration of the procedure was 72 min (range 25 min - 3 h). The mean radiation exposure was 441 dGy/cm (range 70 - 1462), and the mean depth of small-bowel insertion was 150 cm (range 1 - 470 cm). It was possible to evaluate the entire small bowel in four patients (8 %). A new diagnosis was obtained in 26 of the 53 patients (49 %). The findings in the 70 procedures were angiodysplasia (n = 13), ulcerations or erosions (n = 5), jejunitis or ileitis (n = 5), tumors (n = 5), stenosis (n = 4), polyps (n = 5), lymphangiectasias (n = 4), Crohn’s disease (n = 4), and normal (n = 17). DBE resulted in a therapeutic intervention (endoscopic, medical or surgical, excluding blood transfusions) in 57 % of the patients (30 of 53). The only complication (1.4 %) observed was one case of intraprocedural postpolypectomy bleeding, which resolved with injection of epinephrine. Conclusion: In almost two-thirds of the patients examined, DBE was clinically useful for obtaining a new diagnosis and starting new treatments, changing existing treatments, carrying out surgical intervention, or providing therapeutic endoscopy. DBE is a useful and safe method of obtaining tissue for diagnosis, providing hemostasis, and carrying out polypectomy.

6 December 2008 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
KMKlaus Mönkemüller
Klaus Mönkemüller
LFLucia C. Fry
Lucia C. Fry
MBMichael Bellutti
Michael Bellutti
HNHelmut Neumann
Helmut Neumann
PMPeter Malfertheiner
Peter Malfertheiner

25 January 2007 in Endoscopy
Verified
Journal Article
Closed access
PDF file
KMK. Mönkemüller
K. Mönkemüller
LFL. Fry
L. Fry
MEM. Ebert
M. Ebert
MBM. Bellutti
M. Bellutti
Marino VeneritoMarino Venerito
Marino Venerito
PMP. Malfertheiner
P. Malfertheiner
Background and study aims: Patients with familial adenomatous polyposis (FAP) are at increased risk of developing duodenal and jejunal adenocarcinomas. The aim of this study was to assess the usefulness of double-balloon enteroscopy- (DBE-) assisted chromoendoscopy for the detection and characterization of small-bowel polyps in patients with FAP. Patients and methods: We performed a prospective evaluation of patients with clinically and genetically proved FAP who were enrolled in an endoscopic surveillance program. DBE was performed using a Fujinon intestinoscope (FN 450P 5/20; Fujinon Corp., Omiya, Japan), and chromoendoscopy was performed using indigo carmine. The severity of small bowel polyposis was based on the Spigelman-Saurin classification. Results: Nine patients underwent DBE-assisted chromoendoscopy. Small-bowel polyps (including papillary adenomas) were detected in seven patients (88 %). The mean depth of small-bowel insertion was 180 cm (range 120 - 320 cm). The mean Spigelman-Saurin score was 4.6 (range 0 - 8). Jejunal polyps were detected in six patients (67 %). Chromoendoscopy aided in the detection of additional polyps in two patients. In one patient the polyps were flat and only visible with chromoendoscopy (biopsy confirmed these to be adenomas). Jejunal polyps and advanced neoplasms were more frequent in patients with APC gene mutations in exon 15. The following endoscopic therapies were performed: polypectomy (n = 1), duodenal mucosectomy (n = 1), and ablation therapy with argon plasma coagulation (n = 2). Conclusions: DBE was found to be a helpful method for the evaluation of small-bowel polyps in patients with FAP. DBE-assisted chromoendoscopy was of further assistance for the detection of jejunal polyps.

1 February 2005 in Digestive Diseases and Sciences
Verified
Journal Article
Closed access
PDF file
KMKlaus E. Mönkemüller
Klaus E. Mönkemüller
ALAudrey J. Lazenby
Audrey J. Lazenby
DLDavid H. Lee
David H. Lee
RLRobert Loudon
Robert Loudon
CWC. Mel Wilcox
C. Mel Wilcox

18 February 2008 in Endoscopy
Verified
Journal Article
Closed access
PDF file
KMK. Mönkemüller
K. Mönkemüller
LFL. C. Fry
L. C. Fry
MBM. Bellutti
M. Bellutti
HNH. Neumann
H. Neumann
PMP. Malfertheiner
P. Malfertheiner
A 60-year-old man underwent pancreatic necrosectomy and a Roux-en-Y anastomosis. Before surgery the patient had undergone an endoscopic retrograde cholangiopancreatography (ERCP) with biliary stent placement, but this stent could not be removed intra-operatively. ERCP was carried out using the Fujinon double-balloon enteroscope (EN-450T5I, Fujinon, Saitama, Japan). For the ERCP we did not place a balloon on the tip of the enteroscope. Advancement of the enteroscope and overtube was accomplished using the push-and-pull method. Once the anastomosis was localized, the overtube was advanced towards the tip of the scope and the balloon was inflated. The enteroscope was then advanced into the afferent loop, and once it was 20 cm inside of the loop, the overtube balloon was deflated and advanced towards the tip of the scope. These push-and-pull maneuvers were repeated until the pouch of the afferent limb was visualized. The protruding stent helped localize the major papilla ([ Fig. 1 ]). The stent was then grasped with a snare and retrieved ([ Fig. 2 ]). Fig. 1 After entering the blind pouch of the afferent limb a stent exiting the ampulla of Vater was visualized. Fig. 2 The stent was then grasped with a snare and retrieved. A 36-year-old man with chronic pancreatitis underwent a pylorus-preserving Whipple’s operation with Roux-en-Y hepaticojejunostomy. He presented because of cholestasis. ERCP was carried out using the single-balloon method described above. Sludge was found “glued” to the orifice of the hepaticojejunostomy ([ Fig. 3 ]). The sludge was removed using a stone retrieval basket ([ Fig. 4 ] and [ 5 ] ). Fig. 3 Endoscopic view of the hepaticojejunostomy to which a large mass of sludge was found “glued”. Fig. 4 The sludge and stones were removed using a stone retrieval basket. Fig. 5 Note the large hepaticojejunostomy after it has been cleared from the sludge obstructing the bile outflow. There are recent case reports on the feasibility of performing ERCP with the double-balloon enteroscopy in patients with Roux-en-Y anastomosis [ 1 ] [ 2 ]. Our cases suggest that ERCP using the single-balloon enteroscopy approach permits biliary interventions in patients with Roux-en-Y anastomosis. A potential advantage of using a single-balloon technique is time saving, as described for single-balloon colonoscopy [ 3 ]. In addition, occasionally the balloon of the scope slips over the tip, diminishing the endoscopic view and thus interfering with diagnostic and therapeutic interventions. Endoscopy_UCTN_Code_CPL_1AI_2AD Endoscopy_UCTN_Code_CPL_1AK_2AJ

1 January 2007 in Scandinavian Journal of Gastroenterology
Verified
Journal Article
Closed access
KMKlaus Mönkemüller
Klaus Mönkemüller
CKClaudia Knippig
Claudia Knippig
SRSteffen Rickes
Steffen Rickes
LFLucia C. Fry
Lucia C. Fry
ASAnnekathrin Schulze
Annekathrin Schulze
PMPeter Malfertheiner
Peter Malfertheiner