Changjie Liu

Changjie Liu

Auto-generated profile, based on publicly available information

Changjie Liu

State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2017 in Sensors
Verified
Journal Article
Open access
PDF file
YTYang Tongyu
Yang Tongyu
ZWZhong Wang
Zhong Wang
ZWZhengang Wu
Zhengang Wu
LXLi Xingqiang
Li Xingqiang
WLWang Lei
Wang Lei
CLChangjie Liu
Changjie Liu
The laser triangulation method is one of the most advanced methods for large inner diameter measurement. Our research group proposed a kind of inner diameter measuring device that is principally composed of three laser displacement sensors known to be fixed in the same plane measurement position. It is necessary to calibrate the direction of the laser beams that are emitted by laser displacement sensors because they do not meet the theoretical model accurately. For the purpose of calibrating the direction of laser beams, a calibration method and mathematical model were proposed. The inner diameter measuring device is equipped with the spindle of the machine tool. The laser beams rotate and translate in the plane and constitute the rotary rays which are driven to scan the inner surface of the ring gauge. The direction calibration of the laser beams can be completed by the sensors’ distance information and corresponding data processing method. The corresponding error sources are analyzed and the validity of the method is verified. After the calibration, the measurement error of the inner diameter measuring device reduced from ± 25 μ m to ± 15 μ m and the relative error was not more than 0.011%.

16 April 2018 in Sensors
Verified
Journal Article
Open access
PDF file
YZYan Zhao
Yan Zhao
YWYiwen Wang
Yiwen Wang
XYXiuling Ye
Xiuling Ye
ZWZhong Wang
Zhong Wang
LFLuhua Fu
Luhua Fu
ZWZhiwei Wang
Zhiwei Wang
Registration is a critical step in multi-sensor dimensional measurement. As the accuracy of registration directly impacts the quality of final results, a reference sphere as a common standard is problematic in high-precision registration. In this paper, a novel method based on a composite standard is proposed to fuse the multiple heterogeneous sensors in high-precision coordinate measuring machines (CMMs), which will void the drawbacks of a reference sphere. The composite standard consists of a cone and cylinder, which share a same central axis. To ensure high precision in the submicron range, or better, the standard is manufactured by an ultra-precision machine. Three features of the composite standard are inspected by three sensors: a video camera (VC), a tactile probe (TP), and a chromatic confocal displacement sensor (CC). All features will concentrate on a common point through which the relation between the three sensors will be obtained. The errors of each measurement were analyzed theoretically, and simulations and real experiments were carried out to verify the composite standard. This study demonstrates that the proposed registration method is stable and that the standard has potential use for the registration of multiple sensors in high-precision dimensional measurement.

14 September 2017 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
YZYan Zhao
Yan Zhao
ZWZhong Wang
Zhong Wang
LFLuhua Fu
Luhua Fu
XQXinghua Qu
Xinghua Qu
HZHeng Zhang
Heng Zhang
CLChangjie Liu
Changjie Liu
Registration of multiple sensors is a basic step in multi-sensor dimensional or coordinate measuring systems before any measurement. In most cases, a common standard is used to be measured by all sensors, and this may work well for general registration of multiple homogeneous sensors. However, when inhomogeneous sensors detect a common standard, it is usually very difficult to obtain the same information, because of the different working principles of the sensors. In this paper, a new method called multiple steps registration is proposed to register two sensors: a video camera sensor (VCS) and a tactile probe sensor (TPS). In this method, the two sensors measure two separated standards: a chrome circle on a reticle and a reference sphere with a constant distance between them, fixed on a steel plate. The VCS captures only the circle and the TPS touches only the sphere. Both simulations and real experiments demonstrate that the proposed method is robust and accurate in the registration of multiple inhomogeneous sensors in a dimensional measurement system.

30 November 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XCXi Chen
Xi Chen
CSChangku Sun
Changku Sun
CLChangjie Liu
Changjie Liu
LFLuhua Fu
Luhua Fu
To realize the measurement and exact reconstruction of a pair of parallel profiles, a new scanning method using four displacement sensors as probes and different probe spacings has been invented with the advantage of preventing data processing error. The measuring device is placed between the measured objects and moved by a scanning stage to collect measurement data of both measured profiles. Considering many existing methods, the high lateral resolution of the reconstruction result and the rejection of the data processing error cannot always be achieved at the same time. When the measured profiles are in the short wavelength range, data processing errors are often on the same order of magnitude as the height difference of the measured profiles. The new method can eliminate both the straightness error of the measurement reference and the data processing error. The exact reconstruction retaining the high lateral resolution and without data processing error can be realized by rational position arrangement of sensors and corresponding processing method of the measurement data. The new method possesses the following advantages: (i) achievement of the exact reconstruction without data processing error; (ii) high lateral resolution not limited by probe spacing; (iii) concise operation without zero calibration of probes; and (iv) suitability for on-machine measurement. The feasibility and advantages of the new method were demonstrated by theoretical analyses, simulations, and experimental results.

22 March 2017 in Sensors
Verified
Journal Article
Open access
PDF file
WLWang Lei
Wang Lei
FYFangyun Yang
Fangyun Yang
LFLuhua Fu
Luhua Fu
ZWZhong Wang
Zhong Wang
TYTongyu Yang
Tongyu Yang
CLChangjie Liu
Changjie Liu
A new method for fast diameter measurement of coaxial holes is studied. The paper describes a multi-layer measuring rod that installs a single laser displacement sensor (LDS) on each layer. This method is easy to implement by rotating the measuring rod, and immune from detecting the measuring rod’s rotation angles, so all diameters of coaxial holes can be calculated by sensors’ values. While revolving, the changing angles of each sensor’s laser beams are approximately equal in the rod’s radial direction so that the over-determined nonlinear equations of multi-layer holes for fitting circles can be established. The mathematical model of the measuring rod is established, all parameters that affect the accuracy of measurement are analyzed and simulated. In the experiment, the validity of the method is verified, the inner diameter measuring precision of 28 μm is achieved by 20 μm linearity LDS. The measuring rod has advantages of convenient operation and easy manufacture, according to the actual diameters of coaxial holes, and also the varying number of holes, LDS’s mounting location can be adjusted for different parts. It is convenient for rapid diameter measurement in industrial use.

6 April 2020 in IEEE Access
Verified
Journal Article
Open access
XCXi Chen
Xi Chen
CSChangku Sun
Changku Sun
LFLuhua Fu
Luhua Fu
CLChangjie Liu
Changjie Liu
A novel system and its corresponding method for the measurement and the exact reconstruction of a pair of parallel profiles are designed. There are six sensors installed on the measuring device and they are divided into two groups with different sensor spacings. The exact reconstruction can be realized under the condition of a high lateral resolution, as the straightness error, the yaw error, the zeroadjustment error, and the data processing error can be all eliminated through two scannings and certain data processing method. The measurement error of the displacement sensors can also be suppressed. The new method has the following advantages: (i) the realization of the exact reconstruction, (ii) a high lateral resolution of the reconstruction result which is independent of the sensor spacings, (iii) the skip of the zero calibration before the measurement process, and (iv) the suppression of the sensor random error. These advantages are demonstrated by the theoretical analyses and the simulations. Experiments are also conducted to prove some of these characteristics.