Hajime Monzen

Hajime Monzen

Auto-generated profile, based on publicly available information

Hajime Monzen

Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka, Japan

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Physica Medica
Verified
Journal Article
Closed access
KKKazuki Kubo
Kazuki Kubo
HMHajime Monzen
Hajime Monzen
KIKentaro Ishii
Kentaro Ishii
MTMikoto Tamura
Mikoto Tamura
RKRyu Kawamorita
Ryu Kawamorita
YNYasumasa Nishimura
Yasumasa Nishimura

20 March 2018 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
YUYoshihiro Ueda
Yoshihiro Ueda
JFJun-Ichi Fukunaga
Jun-Ichi Fukunaga
TKTatsuya Kamima
Tatsuya Kamima
YAYumiko Adachi
Yumiko Adachi
KNKiyoshi Nakamatsu
Kiyoshi Nakamatsu
HMHajime Monzen
Hajime Monzen
The aim of this study was to evaluate the performance of a commercial knowledge-based planning system, in volumetric modulated arc therapy for prostate cancer at multiple radiation therapy departments. In each institute, > 20 cases were assessed. For the knowledge-based planning, the estimated dose (ED) based on geometric and dosimetric information of plans was generated in the model. Lower and upper limits of estimated dose were saved as dose volume histograms for each organ at risk. To verify whether the models performed correctly, KBP was compared with manual optimization planning in two cases. The relationships between the EDs in the models and the ratio of the OAR volumes overlapping volume with PTV to the whole organ volume (Voverlap/Vwhole) were investigated. There were no significant dosimetric differences in OARs and PTV between manual optimization planning and knowledge-based planning. In knowledge-based planning, the difference in the volume ratio of receiving 90% and 50% of the prescribed dose (V90 and V50) between institutes were more than 5.0% and 10.0%, respectively. The calculated doses with knowledge-based planning were between the upper and lower limits of ED or slightly under the lower limit of ED. The relationships between the lower limit of ED and Voverlap/Vwhole were different among the models. In the V90 and V50 for the rectum, the maximum differences between the lower limit of ED among institutes were 8.2% and 53.5% when Voverlap/Vwhole for the rectum was 10%. In the V90 and V50 for the bladder, the maximum differences of the lower limit of ED among institutes were 15.1% and 33.1% when Voverlap/Vwhole for the bladder was 10%. Organs’ upper and lower limits of ED in the models correlated closely with the Voverlap/Vwhole. It is important to determine whether the models in KBP match a different institute’s plan design before the models can be shared.

8 July 2021 in British Journal of Radiology
Verified
Journal Article
Open access
MHMakoto Hosono
Makoto Hosono
Mamoru TakenakaMamoru Takenaka
Mamoru Takenaka
HMHajime Monzen
Hajime Monzen
MTMikoto Tamura
Mikoto Tamura
Masatoshi KudoMasatoshi Kudo
Masatoshi Kudo
YNYasumasa Nishimura
Yasumasa Nishimura
Positron emission tomography (PET–CT) is an essential imaging modality for the management of various diseases. Increasing numbers of PET–CT examinations are carried out across the world and deliver benefits to patients; however, there are concerns about the cumulative radiation doses from these examinations in patients. Compared to the radiation exposure delivered by CT, there have been few reports on the frequency of patients with a cumulative effective radiation dose of ≥100 mSv from repeated PET–CT examinations. The emerging dose tracking system facilitates surveys on patient cumulative doses by PET–CT because it can easily wrap up exposure doses of PET radiopharmaceuticals and CT. Regardless of the use of a dose tracking system, implementation of justification for PET–CT examinations and utilisation of dose reduction measures are key issues in coping with the cumulative dose in patients. Despite all the advantages of PET/MRI such as eliminating radiation exposure from CT and providing good tissue contrast in MRI, it is expensive and cannot be introduced at every facility; thus, it is still necessary to utilise PET–CT with radiation reduction measures in most clinical situations.

1 August 2019 in Physica Medica
Verified
Journal Article
Closed access
TKTatsuya Kamima
Tatsuya Kamima
YUYoshihiro Ueda
Yoshihiro Ueda
JFJun-Ichi Fukunaga
Jun-Ichi Fukunaga
YSYumiko Shimizu
Yumiko Shimizu
MTMikoto Tamura
Mikoto Tamura
HMHajime Monzen
Hajime Monzen

28 June 2017 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
HMHajime Monzen
Hajime Monzen
IKIkuo Kanno
Ikuo Kanno
TFTakahiro Fujimoto
Takahiro Fujimoto
MHMasahiro Hiraoka
Masahiro Hiraoka
Tungsten functional paper (TFP) is a novel paper‐based radiation‐shielding material. We measured the shielding ability of TFP against x‐rays and gamma rays. The TFP was supplied in 0.3‐mm‐thick sheets that contained 80% tungsten powder and 20% cellulose (C6H10O5) by mass. In dose measurements for x‐rays (60, 80, 100, and 120 kVp), we measured doses after through 1, 2, 3, 5, 10, and 12 TFP sheets, as well as 0.3 and 0.5 mm of lead. In lead equivalence measurements, we measured doses after through 2 and 10 TFP sheets for x‐rays (100 and 150 kVp), and 0, 7, 10, 20, and 30 TFP sheets for gamma rays from cesium‐137 source (662 keV). And then, the lead equivalent thicknesses of TFP were determined by comparison with doses after through standard lead plates (purity >99.9%). Additionally, we evaluated uniformity of the transmitted dose by TFP with a computed radiography image plate for 50 kVp x‐rays. A single TFP sheet was found to have a shielding ability of 65%, 53%, 48%, and 46% for x‐rays (60, 80, 100, and 120 kVp), respectively. The lead equivalent thicknesses of two TFP sheets were 0.10 ± 0.02, 0.09 ± 0.02 mmPb, and of ten TFP sheets were 0.48 ± 0.02 and 0.51 ± 0.02 mmPb for 100 and 150 kVp x‐rays, respectively. The lead equivalent thicknesses of 7, 10, 20, and 30 sheets of TFP for gamma rays from cesium‐137 source were estimated as 0.28, 0.43, 0.91, and 1.50 mmPb with an error of ± 0.01 mm. One TFP sheet had nonuniformity, however, seven TFP sheets provided complete shielding for 50 kVp x‐rays. TFP has adequate radiation shielding ability for x‐rays and gamma rays within the energy range used in diagnostic imaging field.