Jonathan W. Weinsaft

Jonathan W. Weinsaft

Auto-generated profile, based on publicly available information

Jonathan W. Weinsaft

Division of Cardiology, Weill Cornell Medicine, New York, New York, USA

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2009 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
JWJonathan W. Weinsaft
Jonathan W. Weinsaft
RKRaymond J. Kim
Raymond J. Kim
MRMichael Ross
Michael Ross
DKDaniel Krauser
Daniel Krauser
SMShant Manoushagian
Shant Manoushagian
RDRichard B. Devereux
Richard B. Devereux

1 May 2016 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
JWJonathan W. Weinsaft
Jonathan W. Weinsaft
JKJiwon Kim
Jiwon Kim
CMChaitanya B. Medicherla
Chaitanya B. Medicherla
CMClaudia L. Ma
Claudia L. Ma
NCNoel C.F. Codella
Noel C.F. Codella
RDRichard B. Devereux
Richard B. Devereux

7 January 2019 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
ABAlex Bratt
Alex Bratt
JKJiwon Kim
Jiwon Kim
MPMeridith Pollie
Meridith Pollie
ABAshley N. Beecy
Ashley N. Beecy
NTNathan H. Tehrani
Nathan H. Tehrani
JWJonathan W. Weinsaft
Jonathan W. Weinsaft
Phase contrast (PC) cardiovascular magnetic resonance (CMR) is widely employed for flow quantification, but analysis typically requires time consuming manual segmentation which can require human correction. Advances in machine learning have markedly improved automated processing, but have yet to be applied to PC-CMR. This study tested a novel machine learning model for fully automated analysis of PC-CMR aortic flow. A machine learning model was designed to track aortic valve borders based on neural network approaches. The model was trained in a derivation cohort encompassing 150 patients who underwent clinical PC-CMR then compared to manual and commercially-available automated segmentation in a prospective validation cohort. Further validation testing was performed in an external cohort acquired from a different site/CMR vendor. Among 190 coronary artery disease patients prospectively undergoing CMR on commercial scanners (84% 1.5T, 16% 3T), machine learning segmentation was uniformly successful, requiring no human intervention: Segmentation time was < 0.01 min/case (1.2 min for entire dataset); manual segmentation required 3.96 ± 0.36 min/case (12.5 h for entire dataset). Correlations between machine learning and manual segmentation-derived flow approached unity (r = 0.99, p < 0.001). Machine learning yielded smaller absolute differences with manual segmentation than did commercial automation (1.85 ± 1.80 vs. 3.33 ± 3.18 mL, p < 0.01): Nearly all (98%) of cases differed by ≤5 mL between machine learning and manual methods. Among patients without advanced mitral regurgitation, machine learning correlated well (r = 0.63, p < 0.001) and yielded small differences with cine-CMR stroke volume (∆ 1.3 ± 17.7 mL, p = 0.36). Among advanced mitral regurgitation patients, machine learning yielded lower stroke volume than did volumetric cine-CMR (∆ 12.6 ± 20.9 mL, p = 0.005), further supporting validity of this method. Among the external validation cohort (n = 80) acquired using a different CMR vendor, the algorithm yielded equivalently small differences (∆ 1.39 ± 1.77 mL, p = 0.4) and high correlations (r = 0.99, p < 0.001) with manual segmentation, including similar results in 20 patients with bicuspid or stenotic aortic valve pathology (∆ 1.71 ± 2.25 mL, p = 0.25). Fully automated machine learning PC-CMR segmentation performs robustly for aortic flow quantification - yielding rapid segmentation, small differences with manual segmentation, and identification of differential forward/left ventricular volumetric stroke volume in context of concomitant mitral regurgitation. Findings support use of machine learning for analysis of large scale CMR datasets.

1 June 2016 in JACC
Verified
Journal Article
Closed access
JWJonathan W. Weinsaft
Jonathan W. Weinsaft
RDRichard B. Devereux
Richard B. Devereux
LPLiliana R. Preiss
Liliana R. Preiss
AFAttila Feher
Attila Feher
MRMary J. Roman
Mary J. Roman
FAFederico M. Asch
Federico M. Asch

1 April 2023 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Open access
YNYasufumi Nagata
Yasufumi Nagata
PBPhilippe B. Bertrand
Philippe B. Bertrand
VBVinit Baliyan
Vinit Baliyan
JKJonathan Kochav
Jonathan Kochav
RKRuth D. Kagan
Ruth D. Kagan
RLrobert a levine
robert a levine
Background: The relation between ventricular arrhythmia and fibrosis in mitral valve prolapse (MVP) is reported, but underlying valve-induced mechanisms remain unknown. We evaluated the association between abnormal MVP-related mechanics and myocardial fibrosis, and their association with arrhythmia. Methods: We studied 113 patients with MVP with both echocardiogram and gadolinium cardiac magnetic resonance imaging for myocardial fibrosis. Two-dimensional and speckle-tracking echocardiography evaluated mitral regurgitation, superior leaflet and papillary muscle displacement with associated exaggerated basal myocardial systolic curling, and myocardial longitudinal strain. Follow-up assessed arrhythmic events (nonsustained or sustained ventricular tachycardia or ventricular fibrillation). Results: Myocardial fibrosis was observed in 43 patients with MVP, predominantly in the basal-midventricular inferior-lateral wall and papillary muscles. Patients with MVP with fibrosis had greater mitral regurgitation, prolapse, and superior papillary muscle displacement with basal curling and more impaired inferior-posterior basal strain than those without fibrosis ( P <0.001). An abnormal strain pattern with distinct peaks pre–end-systole and post–end-systole in inferior-lateral wall was frequent in patients with fibrosis (81 versus 26%, P 6-month follow-up developed ventricular arrhythmias associated (univariable) with fibrosis, greater prolapse, mitral annular disjunction, and double-peak strain. In multivariable analysis, double-peak strain showed incremental risk of arrhythmia over fibrosis. Conclusions: Basal inferior-posterior myocardial fibrosis in MVP is associated with abnormal MVP-related myocardial mechanics, which are potentially associated with ventricular arrhythmia. These associations suggest pathophysiological links between MVP-related mechanical abnormalities and myocardial fibrosis, which also may relate to ventricular arrhythmia and offer potential imaging markers of increased arrhythmic risk.

1 June 2008 in International Journal of Cardiology
Verified
Journal Article
Closed access
JWJonathan W. Weinsaft
Jonathan W. Weinsaft
MCMatthew D. Cham
Matthew D. Cham
MJMatthew Janik
Matthew Janik
JMJames K. Min
James K. Min
CHClaudia I. Henschke
Claudia I. Henschke
RDRichard B. Devereux
Richard B. Devereux