Iki Adachi

Iki Adachi

Auto-generated profile, based on publicly available information

Iki Adachi

Division of Congenital Heart Surgery, Michael E. DeBakey Department of Surgery, Texas Children's Hospital, Baylor College of Medicine, 6651 Main St, Houston, TX 77030

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2017 in Vascular Health and Risk Management
Verified
Journal Article
Open access
PDF file
SBSarah Burki
Sarah Burki
IAIki Adachi
Iki Adachi
The field of mechanical circulatory support has made great strides in the preceding 2 decades. Although pediatric mechanical circulatory support has lagged behind that of adults, the gap between them is expected to close soon. The only device currently approved by the US Food and Drug Administration for use in children is the Berlin Heart EXCOR ventricular assist device (VAD). The prospective Berlin Heart Investigational Device Exemption Trial demonstrated good outcomes, such as bridge to transplantation or recovery, in ~90% of children supported with this device. However, a high incidence of hemorrhagic and thrombotic complications was also noted. As a result, pediatric centers have just started implanting adult intracorporeal continuous-flow devices in children. This paradigm shift has opened a new era in pediatric mechanical circulatory support. Whereas children on VAD were previously managed exclusively in hospital, therapeutic options such as outpatient management and even destination therapy have been becoming a reality. With continued miniaturization and technological refinements, devices currently in development will broaden the range of options available to children. The HeartMate 3 and HeartWare MVAD are two such compact VADs, which are anticipated to have great potential for pediatric use. Additionally, a pediatric-specific continuous-flow VAD, the newly redesigned Jarvik Infant 2015, is currently undergoing preclinical testing and is expected to undergo a randomized clinical trial in the near future. This review aims to discuss the challenges posed by the use of intracorporeal adult continuous-flow devices in children, as well as to provide our perspective on the future prospects of the field of pediatric VADs.

1 January 2017 in Seminars in Thoracic and Cardiovascular Surgery: Pediatric Cardiac Surgery Annual
Verified
Journal Article
Closed access
PDF file
JBJ. Timothy Baldwin
J. Timothy Baldwin
IAIki Adachi
Iki Adachi
JTJohn Teal
John Teal
CAChristopher A. Almond
Christopher A. Almond
RJRobert D. Jaquiss
Robert D. Jaquiss
RJRobert Jarvik
Robert Jarvik

1 April 2018 in Translational Pediatrics
Verified
Journal Article
Closed access
PDF file
IAIki Adachi
Iki Adachi
Similar to the adult experience, the use of continuous-flow ventricular assist devices (VADs) has been increasing in the pediatric population. According to the PediMACS registry, continuous-flow VAD currently accounts for >60% of the durable device implantations in the U.S. Nonetheless, the continuous-flow VADs currently in use are designed for adults; this inevitably causes the patient-device size mismatch issue, especially when applied for small children. Pulsatile VADs, therefore, represent the only practical option for this group of patients despite the known risk profile of pulsatile VADs. To address such a frustrating reality, the National Heart, Lung, and Blood Institute (NHLBI) launched the Pediatric Circulatory Support Program in 2004, which is the predecessor of the so-called PumpKIN (Pump for Kids, Infants, and Neonates) program. The goal of this program was to develop mechanical circulatory support devices specifically designed for small children. As a result of extensive efforts of the multi-disciplinary team involving clinicians, scientists, manufactures, and federal agencies, the Infant Jarvik 2015, one of the original devices within the Pediatric Circulatory Support Program, has become the first continuous-flow VAD specifically designed for small children that obtained the Investigational Device Exemption (IDEs) from the U.S. Food and Drug Administration (FDA). This approval is a prerequisite to initiate a clinical trial (i.e., the PumpKIN trial). This article describes the history, current status, and future perspectives of this extremely challenging project, with a focus on the lessons we have learned over the decade.

1 February 2015 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
IAIki Adachi
Iki Adachi
MKMuhammad S. Khan
Muhammad S. Khan
FGFrancisco A. Guzmán-Pruneda
Francisco A. Guzmán-Pruneda
CFCharles D. Fraser
Charles D. Fraser
CMCarlos M. Mery
Carlos M. Mery
JHJeffrey S. Heinle
Jeffrey S. Heinle

1 August 2015 in The Journal of Heart and Lung Transplantation
Verified
Journal Article
Closed access
MKMuhammad S. Khan
Muhammad S. Khan
WZWei Zhang
Wei Zhang
RTRachel A. Taylor
Rachel A. Taylor
EME. Dean McKenzie
E. Dean McKenzie
GMGeorge B. Mallory
George B. Mallory
IAIki Adachi
Iki Adachi

1 January 2017 in Seminars in Thoracic and Cardiovascular Surgery: Pediatric Cardiac Surgery Annual
Verified
Journal Article
Closed access
IAIki Adachi
Iki Adachi
SBSarah Burki
Sarah Burki
CFCharles D. Fraser
Charles D. Fraser