Raymond Bunker

Raymond Bunker

Auto-generated profile, based on publicly available information

Raymond Bunker

Pacific Northwest National Laboratory

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2014 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
RAR. Agnese
R. Agnese
AAA. J. Anderson
A. J. Anderson
MAM. Asai
M. Asai
DBD. Balakishiyeva
D. Balakishiyeva
RTR. Basu Thakur
R. Basu Thakur
(C(SuperCDMS Collaboration)
(SuperCDMS Collaboration)
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg days was analyzed for WIMPs with mass <30  GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2×10−42  cm2 at 8  GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses <6  GeV/c2.

16 December 2013 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
RAR. Agnese
R. Agnese
ZAZ. Ahmed
Z. Ahmed
AAA. J. Anderson
A. J. Anderson
SAS. Arrenberg
S. Arrenberg
DBD. Balakishiyeva
D. Balakishiyeva
JZJ. Zhang
J. Zhang
We report results of a search for weakly interacting massive particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg day of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41−0.08+0.20(stat)−0.24+0.28(syst). Other known backgrounds from neutrons and Pb206 are limited to <0.13 and <0.08 events at the 90% confidence level, respectively. The exposure of this analysis is equivalent to 23.4 kg day for a recoil energy range of 7–100 keV for a WIMP of mass 10  GeV/c2. The probability that the known backgrounds would produce three or more events in the signal region is 5.4%. A profile likelihood ratio test of the three events that includes the measured recoil energies gives a 0.19% probability for the known-background-only hypothesis when tested against the alternative WIMP+background hypothesis. The highest likelihood occurs for a WIMP mass of 8.6  GeV/c2 and WIMP-nucleon cross section of 1.9×10−41  cm2.

17 February 2016 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
RAR. Agnese
R. Agnese
AAA. J. Anderson
A. J. Anderson
TAT. Aramaki
T. Aramaki
MAM. Asai
M. Asai
WBW. Baker
W. Baker
SCSuperCDMS Collaboration
SuperCDMS Collaboration
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg day, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5  GeV/c2.

30 March 2011 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
ZAZ. Ahmed
Z. Ahmed
DAD. S. Akerib
D. S. Akerib
SAS. Arrenberg
S. Arrenberg
CBC. N. Bailey
C. N. Bailey
DBD. Balakishiyeva
D. Balakishiyeva
CCCDMS Collaboration
CDMS Collaboration
We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from weakly interacting massive particles (WIMPs) with masses below ∼10  GeV/c2. This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9  GeV/c2 and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.

7 April 2017 in Physical Review D
Verified
Journal Article
Open access
PDF file
RAR. Agnese
R. Agnese
AAA. J. Anderson
A. J. Anderson
TAT. Aramaki
T. Aramaki
IAI. Arnquist
I. Arnquist
WBW. Baker
W. Baker
SCSuperCDMS Collaboration
SuperCDMS Collaboration
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass particles (with masses ≤10  GeV/c2) that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ∼1×10−43  cm2 for a dark matter particle mass of 1  GeV/c2, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low-energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced H3 and naturally occurring Si32 will be present in the detectors at some level. Even if these backgrounds are 10 times higher than expected, the science reach of the HV detectors would be over 3 orders of magnitude beyond current results for a dark matter mass of 1  GeV/c2. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particles with masses ≳5  GeV/c2. The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the “neutrino floor,” where coherent scatters of solar neutrinos become a limiting background.

5 January 2009 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
ZAZ. Ahmed
Z. Ahmed
DAD. S. Akerib
D. S. Akerib
SAS. Arrenberg
S. Arrenberg
MAM. J. Attisha
M. J. Attisha
CBC. N. Bailey
C. N. Bailey
BYB. A. Young
B. A. Young
We report results from the Cryogenic Dark Matter Search at the Soudan Underground Laboratory (CDMS II) featuring the full complement of 30 detectors. A blind analysis of data taken between October 2006 and July 2007 sets an upper limit on the weakly interacting massive particle (WIMP) nucleon spin-independent cross section of 6.6×10−44  cm2 (4.6×10−44  cm2 when combined with previous CDMS II data) at the 90% confidence level for a WIMP mass of 60  GeV/c2. This achieves the best sensitivity for dark matter WIMPs with masses above 44  GeV/c2, and significantly restricts the parameter space for some favored supersymmetric models.