Piotr Zygmanski

Piotr Zygmanski

Auto-generated profile, based on publicly available information

Piotr Zygmanski

Department of Radiation Oncology, Brigham and Women's Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
PZPiotr Zygmanski
Piotr Zygmanski
BLBo Liu
Bo Liu
PTPanagiotis Tsiamas
Panagiotis Tsiamas
FCFulya Cifter
Fulya Cifter
MPMarkus Petersheim
Markus Petersheim
ESErno Sajo
Erno Sajo
Recently, interactions of x-rays with gold nanoparticles (GNPs) and the resulting dose enhancement have been studied using several Monte Carlo (MC) codes (Jones et al 2010 Med. Phys. 37 3809–16, Lechtman et al 2011 Phys. Med. Biol. 56 4631–47, McMahon et al 2011 Sci. Rep. 1 1–9, Leung et al 2011 Med. Phys. 38 624–31). These MC simulations were carried out in simplified geometries and provided encouraging preliminary data in support of GNP radiotherapy. As these studies showed, radiation transport computations of clinical beams to obtain dose enhancement from nanoparticles has several challenges, mostly arising from the requirement of high spatial resolution and from the approximations used at the interface between the macroscopic clinical beam transport and the nanoscopic electron transport originating in the nanoparticle or its vicinity. We investigate the impact of MC simulation geometry on the energy deposition due to the presence of GNPs, including the effects of particle clustering and morphology. Dose enhancement due to a single and multiple GNPs using various simulation geometries is computed using GEANT4 MC radiation transport code. Various approximations in the geometry and in the phase space transition from macro- to micro-beams incident on GNPs are analyzed. Simulations using GEANT4 are compared to a deterministic code CEPXS/ONEDANT for microscopic (nm–µm) geometry. Dependence on the following microscopic (µ) geometry parameters is investigated: µ-source-to-GNP distance (µSAD), µ-beam size (µS), and GNP size (µC). Because a micro-beam represents clinical beam properties at the microscopic scale, the effect of using different types of micro-beams is also investigated. In particular, a micro-beam with the phase space of a clinical beam versus a plane-parallel beam with an equivalent photon spectrum is characterized. Furthermore, the spatial anisotropy of energy deposition around a nanoparticle is analyzed. Finally, dependence of dose enhancement on the number of GNPs in a finite cluster of nanoparticles is determined. Simulations were performed for 100 nm GNPs irradiated in water phantom by various monoenergetic (11 keV–1 MeV) and spectral (50 kVp) sources. The dose enhancement ratio (DER) is very sensitive to the specific simulation geometry (µSAD, µS, µC parameters) and µ-source type. For a single GNP the spatial distribution of DER is found to be nearly isotropic with limited magnitude and relatively short range (∼100–200 nm for DER significantly greater than 1). For a cluster of GNPs both the magnitude and range are found much greater (∼1–2 µm). The relation between DER for a cluster of GNPs and a single GNP is strongly nonlinear. Relatively strong dependence of DER on the simulation micro-geometry cautions future studies and the interpretation of existing MC results obtained in different simulations geometries. The nonlinear relation between DER for a single and multiple GNPs suggests that parameters such as the number of adjacent nanoparticles per cell and the distances between the GNPs and the cellular target may be important in assessing the biological effectiveness associated with GNP.

1 March 2016 in British Journal of Radiology
Verified
Journal Article
Closed access
PZPiotr Zygmanski
Piotr Zygmanski
ESErno Sajo
Erno Sajo
We review radiation transport and clinical beam modelling for gold nanoparticle dose-enhanced radiotherapy using X-rays. We focus on the nanoscale radiation transport and its relation to macroscopi...

19 September 2003 in Medical Physics
Verified
Journal Article
Closed access
PZPiotr Zygmanski
Piotr Zygmanski
JKJong H. Kung
Jong H. Kung
SJSteve B. Jiang
Steve B. Jiang
LCLee Chin
Lee Chin

14 January 2013 in Medical Physics
Verified
Journal Article
Closed access
PZPiotr Zygmanski
Piotr Zygmanski
WHWolfgang Hoegele
Wolfgang Hoegele
PTPanagiotis Tsiamas
Panagiotis Tsiamas
FCFulya Cifter
Fulya Cifter
WNWil Ngwa
Wil Ngwa
ESErno Sajo
Erno Sajo

6 March 2014 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
PZP. Zygmanski
P. Zygmanski
CAC. Abkai
C. Abkai
ZHZ. Han
Z. Han
YSY. Shulevich
Y. Shulevich
DMD. Menichelli
D. Menichelli
JHJ. Hesser
J. Hesser
The purpose of this study is to characterize dosimetric properties of thin film photovoltaic sensors as a platform for development of prototype dose verification equipment in radiotherapy. Towards this goal, flexible thin‐film sensors of dose with embedded data acquisition electronics and wireless data transmission are prototyped and tested in kV and MV photon beams. Fundamental dosimetric properties are determined in view of a specific application to dose verification in multiple planes or curved surfaces inside a phantom. Uniqueness of the new thin‐film sensors consists in their mechanical properties, low‐power operation, and low‐cost. They are thinner and more flexible than dosimetric films. In principle, each thin‐film sensor can be fabricated in any size (mm2 – cm2 areas) and shape. Individual sensors can be put together in an array of sensors spreading over large areas and yet being light. Photovoltaic mode of charge collection (of electrons and holes) does not require external electric field applied to the sensor, and this implies simplicity of data acquisition electronics and low power operation. The prototype device use for testing consists of several thin film dose sensors, each of about area, connected to simple readout electronics. Sensitivity of the sensors is determined per unit area and compared to EPID sensitivity, as well as other standard photodiodes. Each sensor independently measures dose and is based on commercially available flexible thin‐film aSi photodiodes. Readout electronics consists of an ultra low‐power microcontroller, radio frequency transmitter, and a low‐noise amplification circuit implemented on a flexible printed circuit board. Detector output is digitized and transmitted wirelessly to an external host computer where it is integrated and processed. A megavoltage medical linear accelerator (Varian Tx) equipped with kilovoltage online imaging system and a Cobalt source are use to irradiate different thin‐film detector sensors in a Solid Water phantom under various irradiation conditions. Different factors are considered in characterization of the device attributes: energies (80 kVp, 130 kVp, 6 MV, 15 MV), dose rates (different ms × mA, 100–600 MU/min), total doses (0.1 cGy‐500 cGy), depths (0.5 cm–20 cm), irradiation angles with respect to the detector surface (0°‐180°), and IMRT tests (closed MLC, sweeping gap). The detector response to MV radiation is both linear with total dose (~1‐400 cGy) and independent of dose rate (100‐600 Mu/min). The sensitivity per unit area of thin‐film sensors is lower than for aSi flat‐panel detectors, but sufficient to acquire stable and accurate signals during irradiations. The proposed thin‐film photodiode system has properties which make it promising for clinical dosimetry. Due to the mechanical flexibility of each sensor and readout electronics, low‐cost, and wireless data acquisition, it could be considered for quality assurance (e.g., IMRT, mechanical linac QA), as well as real‐time dose monitoring in challenging setup configurations, including large area and 3D detection (multiple planes or curved surfaces).PACS number: 87.56.Fc

1 February 2014 in Physica Medica
Verified
Journal Article
Closed access
PTP. Tsiamas
P. Tsiamas
ESErno Sajo
Erno Sajo
FCF. Cifter
F. Cifter
KTK. Theodorou
K. Theodorou
CKC. Kappas
C. Kappas
PZP. Zygmanski
P. Zygmanski