Oliver Bieri

Oliver Bieri

Auto-generated profile, based on publicly available information

Oliver Bieri

Division of Radiological Physics, Department of Radiology University of Basel Hospital Basel Switzerland

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2005 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
OBO. Bieri
O. Bieri
MMM. Markl
M. Markl
KSKlaus Scheffler
Klaus Scheffler
Balanced steady‐state free precession (SSFP) completely compensates for all gradients within each repetition time (TR), and is thus very sensitive to any magnetic field imperfection that disturbs the perfectly balanced acquisition scheme. It is demonstrated that balanced SSFP is especially sensitive to changing eddy currents that are induced by stepwise changing phase‐encoding (PE) gradients. In contrast to the linear k‐space trajectory, which has small variations between consecutive encoding steps, other encoding schemes (e.g., centric, random, or segmented orderings) exhibit significant jumps in k‐space between adjacent PE steps, and consequently induce rapidly changing eddy currents. The resulting disturbances induce significant image artifacts, such that compensation strategies are essential when nonlinear PE schemes are applied. Although direct annihilation of the induced eddy currents by additional, opposing magnetic fields has been investigated, it is limited by uncertainty regarding the time evolution of induced eddy currents. A generic (and thus system‐unrelated) compensation strategy is proposed that consists of “pairing” of consecutive PE steps. Another approach is based on partial dephasing along the slice direction that annihilates eddy‐current‐induced signal oscillations. Both pairing of the PE steps and “through‐slice equilibration” are easy to implement and allow the use of arbitrary k‐space trajectories for balanced SSFP. Magn Reson Med 54:129–137, 2005.

10 October 2006 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
OBO. Bieri
O. Bieri
KSKlaus Scheffler
Klaus Scheffler
Balanced steady‐state free precession (bSSFP) has become increasingly important in clinical applications. Its signal properties have been investigated over several years by many groups, and various critical factors for bSSFP signal intensity and stability, such as off‐resonances, flow, and eddy currents, have been identified. It is generally accepted that bSSFP signal intensity is a function of relaxation times, excitation angles, and spin densities only. While this is true for simple phantoms, it appears that signals from tissues are significantly less intense than predicted by theory. This work demonstrates that the molecular origin of this apparent signal reduction is due to on‐resonance magnetization transfer (MT). High flip angles in combination with very short repetition times (TRs), as commonly used for bSSFP, lead to a considerable saturation in the fraction of macromolecular (MM) pool protons. As a result, bSSFP signal is strongly attenuated by up to a factor of 2 in the human brain compared to the signal expected from theory. Magn Reson Med, 2006.

13 June 2013 in European Radiology
Verified
Journal Article
Open access
PDF file
VJVladimir Juras
Vladimir Juras
SASebastian Apprich
Sebastian Apprich
PSPavol Szomolanyi
Pavol Szomolanyi
OBOliver Bieri
Oliver Bieri
XDXeni Deligianni
Xeni Deligianni
Siegfried TrattnigSiegfried Trattnig
Siegfried Trattnig
Objective To compare mono- and bi-exponential T2* analysis in healthy and degenerated Achilles tendons using a recently introduced magnetic resonance variable-echo-time sequence (vTE) for T2* mapping. Methods Ten volunteers and ten patients were included in the study. A variable-echo-time sequence was used with 20 echo times. Images were post-processed with both techniques, mono- and bi-exponential [T2*m, short T2* component (T2*s) and long T2* component (T2*l)]. The number of mono- and bi-exponentially decaying pixels in each region of interest was expressed as a ratio (B/M). Patients were clinically assessed with the Achilles Tendon Rupture Score (ATRS), and these values were correlated with the T2* values. Results The means for both T2*m and T2*s were statistically significantly different between patients and volunteers; however, for T2*s, the P value was lower. In patients, the Pearson correlation coefficient between ATRS and T2*s was −0.816 (P = 0.007). Conclusion The proposed variable-echo-time sequence can be successfully used as an alternative method to UTE sequences with some added benefits, such as a short imaging time along with relatively high resolution and minimised blurring artefacts, and minimised susceptibility artefacts and chemical shift artefacts. Bi-exponential T2* calculation is superior to mono-exponential in terms of statistical significance for the diagnosis of Achilles tendinopathy. Key Points • Magnetic resonance imaging offers new insight into healthy and diseased Achilles tendons • Bi-exponential T2* calculation in Achilles tendons is more beneficial than mono-exponential • A short T2* component correlates strongly with clinical score • Variable echo time sequences successfully used instead of ultrashort echo time sequences

28 June 2013 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
OBOliver Bieri
Oliver Bieri
Purpose The speed limit for three-dimensional Fourier-encoded steady state free precession (SSFP) imaging is explored on a clinical whole body system and pushed toward a pulse repetition time (TR) close to or even below the 1 ms regime; in the following referred to as ultra-fast SSFP imaging. Methods To this end, contemporary optimization strategies, such as efficient gradient switching patterns, partial echoes, ramp sampling techniques, and a target-related design of excitation pulses were applied to explore the lower boundaries in TR for SSFP-based Cartesian imaging. Results Generally, minimal TR was limited in vivo by peripheral nerve stimulation, allowing a TR ∼1 ms for isotropic resolutions down to about 2 mm. As a result, ultra-fast balanced SSFP provides artifact-free images even for targets with severe susceptibility variations, and native high-resolution structural and functional in vivo 1H imaging of the human lung is demonstrated at 1.5 T. Conclusion On clinical whole body MRI systems, the TR of SSFP-based Cartesian imaging can be pushed toward the 1 ms regime. As a result, ultra-fast SSFP protocols might represent a promising new powerful approach for SSFP-based imaging, not only for lung but also in a variety of clinical and scientific applications. Magn Reson Med 70:657–663, 2013.

10 January 2023 in Journal of Cystic Fibrosis
Verified
Journal Article
Closed access
CSCarmen Streibel
Carmen Streibel
CWCorin C. Willers
Corin C. Willers
OPOrso Pusterla
Orso Pusterla
GBGrzegorz Bauman
Grzegorz Bauman
ESEnno Stranzinger
Enno Stranzinger
EKElisabeth Kieninger
Elisabeth Kieninger

2 September 2005 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
OBO. Bieri
O. Bieri
KSKlaus Scheffler
Klaus Scheffler
In balanced steady‐state free precession (b‐SSFP) sequences, uncompensated first‐order moments of encoding gradients induce a nonconstant phase evolution for moving spins within the excitation train, resulting in signal loss and image artifacts. To restore these flow‐related phase perturbations, “pairing” of consecutive phase‐encoding (PE) steps is compared with a fully flow‐compensated sequence using compensating gradient waveforms along all three encoding directions. In volunteer studies, the quality of images acquired with the “pairing” technique was comparable to that of images obtained with the fully flow‐compensated technique, regardless of the selected view‐ordering scheme used for data acquisition. Nevertheless, the results of phantom experiments indicate that the pairing technique becomes ineffective at flow velocities exceeding roughly 0.5–1 m/s. Consequently, the additional scan time required to null the first gradient moments in a flow‐compensated b‐SSFP sequence makes the “pairing” technique preferable for applications in which slow to moderate flow velocities can be expected. Magn Reson Med, 2005.