Zeliha Şanıvar Abbasgholızadeh

Dr. Zeliha Şanıvar Abbasgholızadeh


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in International Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
ZAZeliha Şanıvar Abbasgholızadeh
Zeliha Şanıvar Abbasgholızadeh
BEB. Evren
B. Evren
YOY. Ozkan
Y. Ozkan

1 January 2025 in Journal of Applied Oral Science
Verified
Journal Article
Open access
SSSevda Miray Soydaş Smail
Sevda Miray Soydaş Smail
ZAZeliha Şanıvar Abbasgholızadeh
Zeliha Şanıvar Abbasgholızadeh
EKErkut Kahramanoğlu
Erkut Kahramanoğlu
Introduction: According to the latest international consensus in 2018, sleep bruxism is the activity of the masticatory muscles during sleep characterized by rhythmic or non-rhythmic teeth clenching or grinding. Regarding its harmful effects, bruxism is considered one of the predisposing factors of tooth wear and temporomandibular joint diseases. Occlusal splint therapy is the most frequently used treatment for minimizing these harmful effects. Objectives: This study compared the volumetric wear loss and pain scores between digitally and conventionally manufactured occlusal splints for individuals with sleep bruxism. Methodology: A total of 30 individuals diagnosed with sleep bruxism were selected following the inclusion criteria and randomly divided into two groups. Pain scores were subjectively reported using a visual analog scale. Volumetric wear loss of the occlusal splint surface was measured using the Geomagic software. Data were analyzed with SPSS version 25.0. Results: At the six-month follow-up, conventionally manufactured splints (103.53±41.23) showed a volumetric loss significantly higher than that the digital ones (62.33±26.29) (p=0.005). We found no significant difference between the two splint types regarding VAS scores. Conclusion: Occlusal splint wear can gradually alter the balance of occlusal contact and potentially reduce its therapeutic effectiveness, highlighting the importance of using wear-resistant materials. Our findings indicate that digital manufacturing processes provide advantages due to their long-term clinical outcomes.

29 December 2023 in Clinical and Experimental Health Sciences
Verified
Journal Article
Closed access
GÇGülay Çakir
Gülay Çakir
ZAZeliha Şanıvar Abbasgholızadeh
Zeliha Şanıvar Abbasgholızadeh
YAYilmaz Umut Aslan
Yilmaz Umut Aslan
Objective: To evaluate the shear bond strength (SBS) of yttrium-stabilized tetragonal zirconia polycrystals bonded to titanium alloys via different surface treatment methods using four different cements. Methods: Eighty titanium and monolithic zirconia discs were prepared with computer-aided design/manufacturing (CAD/CAM) technology. All titanium discs and 40 of monolithic zirconia discs were polished by using silicon carbide paper and sandblasted with 50 μm aluminum oxide (Al2O3). Tribochemical silica coating was applied to remaining 40 monolithic zirconia discs. The monolithic zirconia discs were divided into eight groups after surface treatment (n=10). Titanium discs were cemented using conventional glass ionomer cement (GIC), resin-modified GIC, self- adhesive resin cement, and dual-cure resin cement. The SBS test was performed using a universal testing machine. The failure patterns were examined by using a scanning electron microscope (SEM). Data were statistically analyzed with one-way analysis of variance (ANOVA), two-way ANOVA and Tukey’s test (α<.05). Results: The SBS values differed according to the surface treatment methods and cements used (p<.001). The highest and lowest SBS values were measured in the tribochemical-silica-coated G-CEM ONE (34.77±5.53 MPa) and Al2O3 sandblasted GC Fuji I (3.30±0.77 MPa) cement groups, respectively. Failure analysis revealed that 41.25%, 31.75% and 25% of the failures were cohesive, adhesive, and combined failures, respectively. Conclusion: The SBS values between the monolithic zirconia and titanium alloy were significantly higher in the resin cement groups containing 10-methacryloyloxydecyl dihydrogen thiophosphate and 10 methacryloyloxydecyl dihydrogen phosphate (p<.05). While adhesive and combined failures were observed at high SBS values, cohesive failures were detected as the bonding values decreased.

8 April 2026 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Open access
ZAZeliha Şanıvar Abbasgholızadeh
Zeliha Şanıvar Abbasgholızadeh
EGEzgi Göler
Ezgi Göler
Objective: This in vitro study evaluated the effects of composite material type, margin design (deep margin elevation vs. control), and thermomechanical aging on the marginal gap of CAD/CAM inlay restorations. Materials and Methods: Standardized mesio‐occluso‐distal (MOD) inlay cavities were prepared in extracted human molars, with mesial margins located at the cemento‐enamel junction (control) and distal margins extended 2 mm apical to the CEJ and elevated using three resin composite materials (bulk‐fill, packable, and flowable). CAD/CAM inlays were fabricated and luted. Marginal gap values were measured using scanning electron microscopy at baseline and after thermomechanical aging simulating 1 year of clinical service. Data were analyzed using mixed repeated‐measures ANOVA to evaluate the effects of material type, margin design, aging condition, and their interactions ( α = 0.05). Results: Thermomechanical aging significantly increased marginal gap values ( p < 0.001). Margin design showed a significant effect ( p = 0.015), whereas the main effect of material type was not statistically significant ( p = 0.205). Significant interactions were observed between material type and margin design ( p = 0.008) and among material type, margin design, and aging condition ( p < 0.001). Conclusions: Within the limitations of this current study, thermomechanical aging significantly increased marginal gap values of CAD/CAM inlays. Material type alone did not show a significant main effect on marginal gap. However, significant interaction effects were observed between material type and deep margin elevation, as well as between material type and aging condition.

28 March 2024 in Clinical and Experimental Health Sciences
Verified
Journal Article
Closed access
ZAZeynep Arıkan
Zeynep Arıkan
ZAZeliha Şanıvar Abbasgholızadeh
Zeliha Şanıvar Abbasgholızadeh
YAYilmaz Umut Aslan
Yilmaz Umut Aslan
YÖYasemin Özkan
Yasemin Özkan
Objective: Novel strength-gradient monolithic zirconia is a developed material recently introduced to the market and its mechanical properties should be investigated in vitro. The aim of the study is to compare the wear rates of three different CAD/CAM materials with a chewing simulator after one year of dynamic loading. Methods: 7x7x3 mm discs were prepared from lithium disilicate, strength-gradient monolithic zirconia, and zirconia-reinforced lithium silicate glass ceramic. Both groups were divided into two subgroups (n=12) as glazed and mechanically polished. The samples were scanned with a laser scanner device (SD Mechatronic Laser Scanner LAS-20, Westerham, Germany) to determine the amount of wear. The samples were placed in a chewing simulator (SD Mechatronic Chewing Simulator CS-4.2, Westerham, Germany) for 240 000 cycles which is equivalent to 1 year of clinical use. After the dynamic loading in the chewing simulator, the samples were scanned again in the laser scanner, and the data was obtained. Kruskal Wallis test was used to analyze the data. Results: The amount of wear of each material was found to be statistically significant (p< .05). No significant differences between the polished and glazed groups of Zir and LD were found but glazed CD was significantly more wear-resistant than polished CD (p< .05). Conclusions: Wear is a phenomenon that can be affected by different factors such as microstructure and surface finishing of the materials. Wear resistance should be taken into consideration when choosing a material.

1 January 2025 in European Journal of Research in Dentistry
Verified
Journal Article
Closed access
EKErkut Kahramanoğlu
Erkut Kahramanoğlu
KEKadir Erden
Kadir Erden
ZAZeliha Şanıvar Abbasgholızadeh
Zeliha Şanıvar Abbasgholızadeh
Amaç: İmplant destekli overdenture protez veya konvansiyonel tam protez kullanım tecrübesi olan hastalar arasında, bu iki tedavi yönteminin hasta memnuniyeti açısından karşılaştırılması ve hasta memnuniyetine etki eden faktörlerin değerlendirilmesidir. Gereç ve yöntem: Bu çalışma; Marmara Üniversitesi Diş Hekimliği Fakültesinde tam protez veya implant destekli overdenture protez tedavisi görmüş olan 100 hastaya telefon görüşmesiyle yöneltilen anket soruları ile yürütülmüştür. Anket, hastaların yaş, cinsiyet, eğitim düzeyi gibi dermografik verileri ve protezlerinin fonksiyon, fonasyon, estetik, temizlenebilirlik, uygulama kolaylığı, tedaviye ulaşabilme kolaylığı gibi farklı parametreleriyle ilgili memnuniyetlerini değerlendirmeye yönelik sorulardan oluşmaktadır. Anket sorularının skorlanmasında, görsel analog skala (VAS) kullanılmıştır. Çalışmada elde edilen bulgular %95 güven aralığında, p<0,05 anlamlılık düzeyinde değerlendirilmiştir. Bulgular: Çiğneme rahatlığı, kendini güvende hissetme, yemek yemeye olan ilginin artması konularında implant destekli overdenture protezlerin memnuniyet skorları anlamlı olarak daha yüksektir. Tedaviye ulaşabilme kolaylığı, tedavi kolaylığı ve gıda retansiyonunun azlığı konularında konvansiyonel tam protezler anlamlı olarak daha yüksek memnuniyet skorları sergilemiştir. Estetik, fonasyon, retansiyon, temizlenebilirlik, tat ve koku alma, protezlerin takıp-çıkarılabilme kolaylığı ve genel memnuniyet açısından iki protez tipi arasından birinin diğerine karşı istatistiksel bir üstünlüğü bulunmamaktadır. Sonuç: Her iki protez tipinin de birbirlerine karşı farklı değerlendirmelerde üstünlükleri olsa da hastaların genel memnuniyeti açısından iki protez tipi arasında anlamlı bir fark yoktur.