Dongeun Huh

Dongeun Huh

Auto-generated profile, based on publicly available information

Dongeun Huh

Department of Bioengineering, University of Pennsylvania, Philadelphia, USA

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2015 in Nature Reviews Drug Discovery
Verified
Journal Article
Closed access
PDF file
EEEric W. Esch
Eric W. Esch
ABAnthony Bahinski
Anthony Bahinski
DHDongeun Huh
Dongeun Huh

7 June 2019 in Science
Verified
Journal Article
Open access
PDF file
SPSunghee Estelle Park
Sunghee Estelle Park
AGAndrei Georgescu
Andrei Georgescu
DHDongeun Huh
Dongeun Huh
Recent studies have demonstrated an array of stem cell–derived, self-organizing miniature organs, termed organoids, that replicate the key structural and functional characteristics of their in vivo counterparts. As organoid technology opens up new frontiers of research in biomedicine, there is an emerging need for innovative engineering approaches for the production, control, and analysis of organoids and their microenvironment. In this Review, we explore organ-on-a-chip technology as a platform to fulfill this need and examine how this technology may be leveraged to address major technical challenges in organoid research. We also discuss emerging opportunities and future obstacles for the development and application of organoid-on-a-chip technology.

2 April 2015 in The Journal of Maternal-Fetal & Neonatal Medicine
Verified
Journal Article
Open access
PDF file
JLJi Soo Lee
Ji Soo Lee
RRRoberto Romero
Roberto Romero
YHYu Mi Han
Yu Mi Han
HKHee Chan Kim
Hee Chan Kim
CKChong Jai Kim
Chong Jai Kim
DHDongeun Huh
Dongeun Huh
Objective: Studying the biology of the human placenta represents a major experimental challenge. Although conventional cell culture techniques have been used to study different types of placenta-derived cells, current in vitro models have limitations in recapitulating organ-specific structure and key physiological functions of the placenta. Here we demonstrate that it is possible to leverage microfluidic and microfabrication technologies to develop a microengineered biomimetic model that replicates the architecture and function of the placenta. Materials and methods: A “Placenta-on-a-Chip” microdevice was created by using a set of soft elastomer-based microfabrication techniques known as soft lithography. This microsystem consisted of two polydimethylsiloxane (PDMS) microfluidic channels separated by a thin extracellular matrix (ECM) membrane. To reproduce the placental barrier in this model, human trophoblasts (JEG-3) and human umbilical vein endothelial cells (HUVECs) were seeded onto the opposite sides of the ECM membrane and cultured under dynamic flow conditions to form confluent epithelial and endothelial layers in close apposition. We tested the physiological function of the microengineered placental barrier by measuring glucose transport across the trophoblast-endothelial interface over time. The permeability of the barrier study was analyzed and compared to that obtained from acellular devices and additional control groups that contained epithelial or endothelial layers alone. Results: Our microfluidic cell culture system provided a tightly controlled fluidic environment conducive to the proliferation and maintenance of JEG-3 trophoblasts and HUVECs on the ECM scaffold. Prolonged culture in this model produced confluent cellular monolayers on the intervening membrane that together formed the placental barrier. This in vivo-like microarchitecture was also critical for creating a physiologically relevant effective barrier to glucose transport. Quantitative investigation of barrier function was conducted by calculating permeability coefficients and metabolic rates in varying conditions of barrier structure. The rates of glucose transport and metabolism were consistent with previously reported in vivo observations. Conclusion: The “Placenta-on-a-Chip” microdevice described herein provides new opportunities to simulate and analyze critical physiological responses of the placental barrier. This system may be used to address the major limitations of existing placenta model systems and serve to enable research platforms for reproductive biology and medicine.

1 March 2015 in Annals of the American Thoracic Society
Verified
Journal Article
Closed access
DHDongeun (Dan) Huh
Dongeun (Dan) Huh
Here we describe a microphysiological system that replicates the functional unit of the living human lung. This human "breathing lung-on-a-chip" microdevice provides unique capabilities to reconstitute three-dimensional microarchitecture, dynamic mechanical activity, and integrated physiological function of the alveolar-capillary interface. We demonstrate the potential of this microengineered biomimetic model for screening environmental particulates and modeling complex human disease processes.

20 May 2016 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CBCassidy Blundell
Cassidy Blundell
ETEmily R. Tess
Emily R. Tess
ASAriana S. R. Schanzer
Ariana S. R. Schanzer
CCChristos Coutifaris
Christos Coutifaris
ESEmily J. Su
Emily J. Su
DHDongeun Huh
Dongeun Huh
During human pregnancy, the fetal circulation is separated from maternal blood in the placenta by two cell layers – the fetal capillary endothelium and placental trophoblast. This placental barrier plays an essential role in fetal development and health by tightly regulating the exchange of endogenous and exogenous materials between the mother and the fetus. Here we present a microengineered device that provides a novel platform to mimic the structural and functional complexity of this specialized tissue in vitro. Our model is created in a multilayered microfluidic system that enables co-culture of human trophoblast cells and human fetal endothelial cells in a physiologically relevant spatial arrangement to replicate the characteristic architecture of the human placental barrier. We have engineered this co-culture model to induce progressive fusion of trophoblast cells and to form a syncytialized epithelium that resembles the syncytiotrophoblast in vivo. Our system also allows the cultured trophoblasts to form dense microvilli under dynamic flow conditions and to reconstitute expression and physiological localization of membrane transport proteins, such as glucose transporters (GLUTs), critical to the barrier function of the placenta. To provide a proof-of-principle for using this microdevice to recapitulate native function of the placental barrier, we demonstrated physiological transport of glucose across the microengineered maternal–fetal interface. Importantly, the rate of maternal-to-fetal glucose transfer in this system closely approximated that measured in ex vivo perfused human placentas. Our “placenta-on-a-chip” platform represents an important advance in the development of new technologies to model and study the physiological complexity of the human placenta for a wide variety of applications.

9 July 2015 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
YCYoonseok Choi
Yoonseok Choi
EHEunjeh Hyun
Eunjeh Hyun
JSJeongyun Seo
Jeongyun Seo
CBCassidy Blundell
Cassidy Blundell
HKHee Chan Kim
Hee Chan Kim
DHDongeun Huh
Dongeun Huh
A mounting body of evidence in cancer research suggests that the local microenvironment of tumor cells has a profound influence on cancer progression and metastasis. In vitro studies on the tumor microenvironment and its pharmacological modulation, however, are often hampered by the technical challenges associated with creating physiological cell culture environments that integrate cancer cells with the key components of their native niche such as neighboring cells and extracellular matrix (ECM) to mimic complex microarchitecture of cancerous tissue. Using early-stage breast cancer as a model disease, here we describe a biomimetic microengineering strategy to reconstitute three-dimensional (3D) structural organization and microenvironment of breast tumors in human cell-based in vitro models. Specifically, we developed a microsystem that enabled co-culture of breast tumor spheroids with human mammary ductal epithelial cells and mammary fibroblasts in a compartmentalized 3D microfluidic device to replicate microarchitecture of breast ductal carcinoma in situ (DCIS). We also explored the potential of this breast cancer-on-a-chip system as a drug screening platform by evaluating the efficacy and toxicity of an anticancer drug (paclitaxel). Our microengineered disease model represents the first critical step towards recapitulating pathophysiological complexity of breast cancer, and may serve as an enabling tool to systematically examine the contribution of the breast cancer microenvironment to the progression of DCIS to an invasive form of the disease.