Self-assembling peptides are biomedical materials with unique structures that are formed in response to various environmental conditions. Governed by their physicochemical characteristics, the peptides can form a variety of structures with greater reactivity than conventional non-biological materials. The structural divergence of self-assembling peptides allows for various functional possibilities; when assembled, they can be used as scaffolds for cell and tissue regeneration, and vehicles for drug delivery, conferring controlled release, stability, and targeting, and avoiding side effects of drugs. These peptides can also be used as drugs themselves. In this review, we describe the basic structure and characteristics of self-assembling peptides and the various factors that affect the formation of peptide-based structures. We also summarize the applications of self-assembling peptides in the treatment of various diseases, including cancer. Furthermore, the in-cell self-assembly of peptides, termed reverse self-assembly, is discussed as a novel paradigm for self-assembling peptide-based nanovehicles and nanomedicines.
19 July 2022 in International Journal of Biological Macromolecules
This paper presents the first CMOS Vascular Endothelial Growth Factor (VEGF) sensor for cancer diagnosis directly from human blood. The sensor incorporates a peptide aptamer-based microneedle that allows the detection of electrochemical reactions with VEGF. This results in a capacitance change between the microneedles and then reads out by a two-step capacitance-to-digital converter (CDC). The proposed two-step CDC consists of a coarse 5b slope ADC and a fine 14b continuous-time delta-sigma modulator (CTDSM). During slow peptide-binding, the slope ADC performs a coarse conversion and the results are used to adjust the current level of the stimulator. After settling of the peptide-binding, based on an adjusted stimulation current, the CTDSM measures the small capacitance changes of the sensor. The prototype chip is fabricated in a 65-nm CMOS process, occupying a 0.87 mm2 active area. The power consumption is 270 W. Thanks to the two-step approach, this work achieves a wide dynamic range of 18.3b, covering a large sensor-to-sensor variation. It also achieves a peak resolution of 13.7b, while maintaining <0.02% errors in 1 to 100 nF baseline capacitance. The overall sensor system successfully detects the VEGF in both phosphate-buffered saline (PBS) and human blood serum. Without the use of precision instruments, this work achieves a resolution of 15 fMrms in range of 0.1 to 1000 pM and denotes the clear VEGF selectivity at 40× in PBS and 5× in the blood serum compared to other proteins (IgG, Con A, and cholera toxin).