Mehrnaz Atighehchian

Mehrnaz Atighehchian

Auto-generated profile, based on publicly available information

Mehrnaz Atighehchian

Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PAParisa Abdi
Parisa Abdi
MAMehrnaz Atighehchian
Mehrnaz Atighehchian
AFAmir Reza Farsiani
Amir Reza Farsiani
The aim was to compare measurements of anterior segment biometry parameters using two Scheimpflug tomographies, Pentacam and Sirius to assess the agreement. Prospective cross-sectional observational study. A total of 60 eyes of 30 healthy subjects were included and evaluated with Pentacam followed by Sirius imaging. Corneal indices were performed with two modalities in both eyes including; apical corneal thickness (ACT), corneal thickness at pupil site(PCT), thinnest corneal thickness (TCT), anterior chamber depth (ACD), chamber angle, chamber volume, cornea volume, mean front keratometry (FKm), the radius of corneal curvature at the anterior and posterior surface in steep and flat meridian, anterior astigmatism values, pupil diameter, and horizontal corneal diameter. The Bland–Altman graph and ICC (intra-class correlation were used to establish an agreement and present the similarity of the findings. Most parameters showed perfect agreement. In both devices, the ICC was more than 0.91 in all measurements except for ACD (ICC = 0.820), cylinder axis (ICC = 0.520), TCT(ICC = 0.881), ACT(ICC = 0.672), PCT (ICC = 0.882), chamber angle (ICC = 0.362), pupil diameter(ICC = 0.137). Pentacam yielded higher values that were significant in five parameters including 3.47 μm for TCT, 4.29 µm for PCT, 10.03 mm3 for chamber volume,2.67 mm3 for cornea volume, and 1.49 mm for pupil diameter but there was only a statistically significant difference in cornea volume and pupil diameter (p-value < 0.001). However, in Pentacam only the chamber angle value was 6.44 mm3 lower than Sirius, with a statistically significant difference (p-value < 0.001). Although these two devices had some statistically different results, it seems that they have a good agreement and correlation in most parameters.

7 December 2024 in Medical Mycology Case Reports
Verified
Journal Article
Open access
MAMehrnaz Atighehchian
Mehrnaz Atighehchian
ALAlireza Latifi
Alireza Latifi
ZNZohreh Nozarian
Zohreh Nozarian
FAFahimeh Asadi Amoli
Fahimeh Asadi Amoli
MZMehran Zarei-Ghanavati
Mehran Zarei-Ghanavati
A 42-year-old woman was referred to an emergency department. She had an unresponsive corneal ulcer that was initially diagnosed as Herpes simplex virus keratitis. Later, the microbiological studies revealed fungal keratitis. Although the patient was given topical antifungal medication, the clinical presentation did not support improvement. Despite using antifungal medication, the infiltration continued to progress, and the patient underwent therapeutic penetrating keratoplasty (T-PKP). Corneal tissue was collected and sent for histopathologic and molecular examination. The results revealed the presence of both Acanthamoeba T4 subgroup and Fusarium sp. This case emphasizes the importance of considering Acanthamoeba infection in progressive and nonresponsive infectious keratitis, especially fungal specimens. Polymerase chain reaction (PCR) is an appropriate laboratory molecular diagnostic test for accurate diagnosis of Acanthamoeba keratitis.

23 July 2023 in Journal of Ophthalmic and Vision Research
Verified
Journal Article
Open access
PDF file
ABAmir-Hooshang Beheshtnejad
Amir-Hooshang Beheshtnejad
HGHamed Ghassemi
Hamed Ghassemi
HAHossein Abdolkhalegh
Hossein Abdolkhalegh
MAMehrnaz Atighehchian
Mehrnaz Atighehchian
Purpose: To assess the autofluorescence size and properties of pterygium and pinguecula by anterior segment autofluorescence (AS-AF) imaging and demonstrate the difference of autofluorescence size presented in AS-AF imaging compared to the extend size of the conjunctival lesion measured by anterior segment slit-lamp photography (AS-SLE). Methods: Twenty-five patients with primary pterygium and twenty-five with pinguecula were included in the study. In addition, 25 normal subjects were also enrolled as the control group. The AS-AF characteristics of pterygium and pinguecula lesions were analyzed. The size of lesions displayed in the AS-SLE photography versus the AS-AF images were also compared. AS-AF images were obtained using a Heidelberg retina angiograph which focused on the anterior segment. AS-SLE photography was acquired using a digital imaging system (BX900 HAAG-STREIT). Results: There were 44 (58.7%) male and 31 (41.3%) female patients; 19 (76%) and 20 (80%) patients had bilateral pterygium and pinguecula, respectively. All pinguecula lesions reflected hyperautofluorescence pattern in the AS-AF imaging. In 24 (96%) patients, the hyperautofluoresecence pattern was larger than the size of the clinical lesions displayed with the AS-SLE photography. Twenty-one (84%) patients with pterygium reflected a hyperautofluorescence pattern in AS-AF images; in one (4%) patient, the hyperautofluorescence pattern was larger than the clinical lesion size and four (16%) patients had no autofluorescence patterns in the AS-AF images. In the control group, in 14 (56%) subjects, a hypoautofluorescent pattern was revealed in the conjunctiva in AS-AF images. However, in 11 (44%) patients, hyperautofluorescence patterns were detected. Conclusion: AS-AF is a useful modality to monitor vascularization in conjunctival lesions. Pingueculae and pterygium show hyperautofluorescence in AS-AF imaging. The real size of the pinguecula lesions may be estimated with AS-AF characteristics, mostly presenting larger than the area size in AS-SLE photography. The autofluorescence size of the pterygium is smaller than the extent of visible pterygium in slit-lamp photography.

30 November 2023 in Journal of Ophthalmic and Vision Research
Verified
Journal Article
Open access
PDF file
HGHamed Ghassemi
Hamed Ghassemi
MZMehran Zarei-Ghanavati
Mehran Zarei-Ghanavati
MKMina Khastavan
Mina Khastavan
MAMehrnaz Atighehchian
Mehrnaz Atighehchian
AKAbbas Azimi Khorasani
Abbas Azimi Khorasani
GLGolshan Latifi
Golshan Latifi
Purpose: This study aimed to assess the agreement between topographic indices of healthy subjects and keratoconus (KCN) patients using a swept-source optical coherence tomography (SS-OCT CASIA2) versus a Scheimpflug camera (Pentacam). Methods: 40 eyes of 23 patients with KCN and 40 eyes of 20 healthy subjects were included and evaluated with the CASIA2, followed by the Pentacam. Two consecutive modalities were obtained for one eye of each patient. Corneal parameters, including anterior keratometry at steep (Ks) and flat meridians (Kf), anterior astigmatism, anterior and posterior corneal elevation values, thinnest corneal thickness, and apex corneal thickness, were evaluated. Results: CASIA2 and Pentacam showed perfect agreement (95% limits of agreement (LoA): -0.22 to 0.68, 95% LoA: -1.5 to 1.44 D) and good correlation (Intraclass correlation (ICC):0.986, ICC:0.987; to 0.68, 95% LoA: -1.5 to 1.44 D) and good correlation (Intraclass correlation (ICC):0.986, ICC:0.987; P <0.01) for anterior (Ks) in normal and ectatic corneas, respectively. The cylinder amount had moderate agreement and correlation (95% LoA: -0.55 to 0.47D, ICC: 0.797, P <0.01) in normal, and moderate to strong agreement and correlation (95% LoA: -1.57 to 0.87D, ICC=0.911, P <0.01) in Keratoconic eyes. There was a fair agreement for anterior and posterior corneal elevation values in normal subjects (95% LoA: -3.09 to 4.59, 95% LoA: -6.91 to 7.31D). The thinnest corneal thickness amount had an excellent agreement in normal and KCN patients (ICC: 0.983, 0.953; respectively). Conclusions: Although the devices had different mean indices values, they had a good agreement based on the Bland–Altman plots. Since Pentacam is accepted as the standard tool for diagnosing ectatic cornea, pentacam CASIA2 is also helpful for early diagnosis of KCN.

13 January 2026 in Parasitology Research
Verified
Journal Article
Open access
PDF file
MAMehrnaz Atighehchian
Mehrnaz Atighehchian
ALAlireza Latifi
Alireza Latifi
EKElham Kazemirad
Elham Kazemirad
MKMaryam Kasiri
Maryam Kasiri
MZMehran Zarei-Ghanavati
Mehran Zarei-Ghanavati
This report describes the case of a 28-year-old woman, who presented with a two-week history of severe ocular pain and photophobia in her right eye. She was a soft contact lens wearer with no history of ocular trauma or systemic illness. Ophthalmic examination revealed conjunctival hyperemia, epithelial irregularities, and a developing ring-shaped stromal infiltrate. In vivo confocal microscopy demonstrated double-walled hyperreflective cysts, and culture followed by PCR and sequencing confirmed the presence of Acanthamoeba T4 genotype. Despite intensive treatment with topical polyhexamethylene biguanide, chlorhexidine, propamidine, and voriconazole, as well as oral miltefosine, the infection progressed, leading to stromal necrosis. The patient underwent two therapeutic penetrating keratoplasties; however, the disease continued to advance, eventually resulting in phthisis bulbi and permanent vision loss. This case highlights the potential for aggressive, clinically refractory Acanthamoeba keratitis caused by the T4 genotype, emphasizing the importance of early diagnosis, vigilant monitoring, and timely surgical intervention in resistant cases.

26 September 2024 in International Ophthalmology
Verified
Journal Article
Closed access
PDF file
STSeyed Ali Tabatabaei
Seyed Ali Tabatabaei
ZEZohre Ebrahimi
Zohre Ebrahimi
MSMohammad Soleimani
Mohammad Soleimani
ZMZahra Mahdizad
Zahra Mahdizad
MAMehrnaz Atighechian
Mehrnaz Atighechian
SDShakiba Dehghani
Shakiba Dehghani