Mintu P. Turakhia

Mintu P. Turakhia

Auto-generated profile, based on publicly available information

Mintu P. Turakhia

Department of Medicine, Stanford University School of Medicine, Stanford, CA; iRhythm Technologies Inc, San Francisco, CA

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2019 in The New England journal of medicine
Verified
Journal Article
Closed access
PDF file
MPMarco V. Perez
Marco V. Perez
KMKenneth W. Mahaffey
Kenneth W. Mahaffey
HHHaley Hedlin
Haley Hedlin
JRJohn S. Rumsfeld
John S. Rumsfeld
AGAriadna Garcia
Ariadna Garcia
MTMintu P. Turakhia
Mintu P. Turakhia
Optical sensors on wearable devices can detect irregular pulses. The ability of a smartwatch application (app) to identify atrial fibrillation during typical use is unknown. Participants without atrial fibrillation (as reported by the participants themselves) used a smartphone (Apple iPhone) app to consent to monitoring. If a smartwatch-based irregular pulse notification algorithm identified possible atrial fibrillation, a telemedicine visit was initiated and an electrocardiography (ECG) patch was mailed to the participant, to be worn for up to 7 days. Surveys were administered 90 days after notification of the irregular pulse and at the end of the study. The main objectives were to estimate the proportion of notified participants with atrial fibrillation shown on an ECG patch and the positive predictive value of irregular pulse intervals with a targeted confidence interval width of 0.10. We recruited 419,297 participants over 8 months. Over a median of 117 days of monitoring, 2161 participants (0.52%) received notifications of irregular pulse. Among the 450 participants who returned ECG patches containing data that could be analyzed — which had been applied, on average, 13 days after notification — atrial fibrillation was present in 34% (97.5% confidence interval [CI], 29 to 39) overall and in 35% (97.5% CI, 27 to 43) of participants 65 years of age or older. Among participants who were notified of an irregular pulse, the positive predictive value was 0.84 (95% CI, 0.76 to 0.92) for observing atrial fibrillation on the ECG simultaneously with a subsequent irregular pulse notification and 0.71 (97.5% CI, 0.69 to 0.74) for observing atrial fibrillation on the ECG simultaneously with a subsequent irregular tachogram. Of 1376 notified participants who returned a 90-day survey, 57% contacted health care providers outside the study. There were no reports of serious app-related adverse events. The probability of receiving an irregular pulse notification was low. Among participants who received notification of an irregular pulse, 34% had atrial fibrillation on subsequent ECG patch readings and 84% of notifications were concordant with atrial fibrillation. This siteless (no on-site visits were required for the participants), pragmatic study design provides a foundation for large-scale pragmatic studies in which outcomes or adherence can be reliably assessed with user-owned devices. (Funded by Apple; Apple Heart Study ClinicalTrials.gov number, NCT03335800.)

1 January 2019 in American Heart Journal
Verified
Journal Article
Open access
MTMintu P. Turakhia
Mintu P. Turakhia
MDManisha Desai
Manisha Desai
HHHaley Hedlin
Haley Hedlin
ARAmol Rajmane
Amol Rajmane
NTNisha Talati
Nisha Talati
MPMarco V. Perez
Marco V. Perez
Smartwatch and fitness band wearable consumer electronics can passively measure pulse rate from the wrist using photoplethysmography (PPG). Identification of pulse irregularity or variability from these data has the potential to identify atrial fibrillation or atrial flutter (AF, collectively). The rapidly expanding consumer base of these devices allows for detection of undiagnosed AF at scale. The Apple Heart Study is a prospective, single arm pragmatic study that has enrolled 419,093 participants (NCT03335800). The primary objective is to measure the proportion of participants with an irregular pulse detected by the Apple Watch (Apple Inc, Cupertino, CA) with AF on subsequent ambulatory ECG patch monitoring. The secondary objectives are to: 1) characterize the concordance of pulse irregularity notification episodes from the Apple Watch with simultaneously recorded ambulatory ECGs; 2) estimate the rate of initial contact with a health care provider within 3 months after notification of pulse irregularity. The study is conducted virtually, with screening, consent and data collection performed electronically from within an accompanying smartphone app. Study visits are performed by telehealth study physicians via video chat through the app, and ambulatory ECG patches are mailed to the participants. The results of this trial will provide initial evidence for the ability of a smartwatch algorithm to identify pulse irregularity and variability which may reflect previously unknown AF. The Apple Heart Study will help provide a foundation for how wearable technology can inform the clinical approach to AF identification and screening.

4 January 2011 in Annals of Internal Medicine
Verified
Journal Article
Open access
PDF file
JFJames V. Freeman
James V. Freeman
RZRuo P. Zhu
Ruo P. Zhu
DODouglas K. Owens
Douglas K. Owens
AGAlan M. Garber
Alan M. Garber
DHDavid W. Hutton
David W. Hutton
MTMintu P. Turakhia
Mintu P. Turakhia
Background: Warfarin reduces the risk for ischemic stroke in patients with atrial fibrillation (AF) but increases the risk for hemorrhage. Dabigatran is a fixed-dose, oral direct thrombin inhibitor with similar or reduced rates of ischemic stroke and intracranial hemorrhage in patients with AF compared with those of warfarin. Objective: To estimate the quality-adjusted survival, costs, and cost-effectiveness of dabigatran compared with adjusted-dose warfarin for preventing ischemic stroke in patients 65 years or older with nonvalvular AF. Design: Markov decision model. Data Sources: The RE-LY (Randomized Evaluation of Long-Term Anticoagulation Therapy) trial and other published studies of anticoagulation. The cost of dabigatran was estimated on the basis of pricing in the United Kingdom. Target Population: Patients aged 65 years or older with nonvalvular AF and risk factors for stroke (CHADS2 score ≥1 or equivalent) and no contraindications to anticoagulation. Time Horizon: Lifetime. Perspective: Societal. Intervention: Warfarin anticoagulation (target international normalized ratio, 2.0 to 3.0); dabigatran, 110 mg twice daily (low dose); and dabigatran, 150 mg twice daily (high dose). Outcome Measures: Quality-adjusted life-years (QALYs), costs (in 2008 U.S. dollars), and incremental cost-effectiveness ratios. Results of Base-Case Analysis: The quality-adjusted life expectancy was 10.28 QALYs with warfarin, 10.70 QALYs with low-dose dabigatran, and 10.84 QALYs with high-dose dabigatran. Total costs were $143 193 for warfarin, $164 576 for low-dose dabigatran, and $168 398 for high-dose dabigatran. The incremental cost-effectiveness ratios compared with warfarin were $51 229 per QALY for low-dose dabigatran and $45 372 per QALY for high-dose dabigatran. Results of Sensitivity Analysis: The model was sensitive to the cost of dabigatran but was relatively insensitive to other model inputs. The incremental cost-effectiveness ratio increased to $50 000 per QALY at a cost of $13.70 per day for high-dose dabigatran but remained less than $85 000 per QALY over the full range of model inputs evaluated. The cost-effectiveness of high-dose dabigatran improved with increasing risk for stroke and intracranial hemorrhage. Limitation: Event rates were largely derived from a single randomized clinical trial and extrapolated to a 35-year time frame from clinical trials with approximately 2-year follow-up. Conclusion: In patients aged 65 years or older with nonvalvular AF at increased risk for stroke (CHADS2 score ≥1 or equivalent), dabigatran may be a cost-effective alternative to warfarin depending on pricing in the United States. Primary Funding Source: American Heart Association and Veterans Affairs Health Services Research & Development Service.

7 March 2018 in European Heart Journal
Verified
Journal Article
Open access
PDF file
MTMintu P Turakhia
Mintu P Turakhia
PBPeter J Blankestijn
Peter J Blankestijn
JCJuan-Jesus Carrero
Juan-Jesus Carrero
CCCatherine M Clase
Catherine M Clase
RDRajat Deo
Rajat Deo
CWChristoph Wanner
Christoph Wanner
Patients with chronic kidney disease (CKD) are predisposed to heart rhythm disorders, including atrial fibrillation (AF)/atrial flutter, supraventricular tachycardias, ventricular arrhythmias, and sudden cardiac death (SCD). While treatment options, including drug, device, and procedural therapies, are available, their use in the setting of CKD is complex and limited. Patients with CKD and end-stage kidney disease (ESKD) have historically been under-represented or excluded from randomized trials of arrhythmia treatment strategies, 1 although this situation is changing. 2 Cardiovascular society consensus documents have recently identified evidence gaps for treating patients with CKD and heart rhythm disorders. 3–7

1 August 2013 in The American Journal of Cardiology
Verified
Journal Article
Open access
MTMintu P. Turakhia
Mintu P. Turakhia
DHDonald D. Hoang
Donald D. Hoang
PZPeter Zimetbaum
Peter Zimetbaum
JMJared D. Miller
Jared D. Miller
VFVictor F. Froelicher
Victor F. Froelicher
PHPaul Heidenreich
Paul Heidenreich
Although extending the duration of ambulatory electrocardiographic monitoring beyond 24 to 48 hours can improve the detection of arrhythmias, lead-based (Holter) monitors might be limited by patient compliance and other factors. We, therefore, evaluated compliance, analyzable signal time, interval to arrhythmia detection, and diagnostic yield of the Zio Patch, a novel leadless, electrocardiographic monitoring device in 26,751 consecutive patients. The mean wear time was 7.6 ± 3.6 days, and the median analyzable time was 99% of the total wear time. Among the patients with detected arrhythmias (60.3% of all patients), 29.9% had their first arrhythmia and 51.1% had their first symptom-triggered arrhythmia occur after the initial 48-hour period. Compared with the first 48 hours of monitoring, the overall diagnostic yield was greater when data from the entire Zio Patch wear duration were included for any arrhythmia (62.2% vs 43.9%, p <0.0001) and for any symptomatic arrhythmia (9.7% vs 4.4%, p <0.0001). For paroxysmal atrial fibrillation (AF), the mean interval to the first detection of AF was inversely proportional to the total AF burden, with an increasing proportion occurring after 48 hours (11.2%, 10.5%, 20.8%, and 38.0% for an AF burden of 51% to 75%, 26% to 50%, 1% to 25%, and <1%, respectively). In conclusion, extended monitoring with the Zio Patch for ≤14 days is feasible, with high patient compliance, a high analyzable signal time, and an incremental diagnostic yield beyond 48 hours for all arrhythmia types. These findings could have significant implications for device selection, monitoring duration, and care pathways for arrhythmia evaluation and AF surveillance.

6 July 2020 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
AFAlbert K. Feeny
Albert K. Feeny
MCMina K. Chung
Mina K. Chung
AMAnant Madabhushi
Anant Madabhushi
ZAZachi I. Attia
Zachi I. Attia
MCMaja Cikes
Maja Cikes
PWPaul J. Wang
Paul J. Wang
Artificial intelligence (AI) and machine learning (ML) in medicine are currently areas of intense exploration, showing potential to automate human tasks and even perform tasks beyond human capabilities. Literacy and understanding of AI/ML methods are becoming increasingly important to researchers and clinicians. The first objective of this review is to provide the novice reader with literacy of AI/ML methods and provide a foundation for how one might conduct an ML study. We provide a technical overview of some of the most commonly used terms, techniques, and challenges in AI/ML studies, with reference to recent studies in cardiac electrophysiology to illustrate key points. The second objective of this review is to use examples from recent literature to discuss how AI and ML are changing clinical practice and research in cardiac electrophysiology, with emphasis on disease detection and diagnosis, prediction of patient outcomes, and novel characterization of disease. The final objective is to highlight important considerations and challenges for appropriate validation, adoption, and deployment of AI technologies into clinical practice.