Naveen Subhas

Naveen Subhas

Auto-generated profile, based on publicly available information

Naveen Subhas

Imaging Institute Cleveland Clinic Cleveland Ohio USA

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2014 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
NSNaveen Subhas
Naveen Subhas
APAndrew N. Primak
Andrew N. Primak
NONancy A. Obuchowski
Nancy A. Obuchowski
AGAmit Gupta
Amit Gupta
JPJoshua M. Polster
Joshua M. Polster
JIJoseph P. Iannotti
Joseph P. Iannotti

1 August 2011 in American Journal of Roentgenology
Verified
Journal Article
Closed access
NSNaveen Subhas
Naveen Subhas
AKAmy Kao
Amy Kao
MFMaxime Freire
Maxime Freire
JPJoshua M. Polster
Joshua M. Polster
NONancy A. Obuchowski
Nancy A. Obuchowski
CWCarl S. Winalski
Carl S. Winalski
OBJECTIVE. The purpose of this study was to evaluate the diagnostic performance of sampling perfection with application-optimized contrasts using different flip-angle evolutions (SPACE) 3D fast spin-echo acquisition relative to conventional 2D fast spin-echo acquisition in the 3-T MRI evaluation of the menisci and ligaments of the knee. MATERIALS AND METHODS. Images from all MRI knee examinations performed with a single 3-T system from September 2008 to January 2009 were reviewed. Seventy-one examinations of patients who subsequently underwent knee arthroscopy and an additional 29 examinations of patients who did not undergo surgery were selected for a total of 100 examinations. All imaging was performed with multiplanar conventional 2D and SPACE 3D fast spin-echo acquisitions. Six musculoskeletal radiologists independently reviewed the images. Area under the receiver operating characteristic (ROC) curve was calculated for the menisci and anterior cruciate ligament with arthroscopy as the reference standa...

1 May 2015 in Radiologic Clinics of North America
Verified
Journal Article
Closed access
AGAmit Gupta
Amit Gupta
NSNaveen Subhas
Naveen Subhas
APAndrew N. Primak
Andrew N. Primak
MNMathias Nittka
Mathias Nittka
KLKecheng Liu
Kecheng Liu

1 August 2016 in American Journal of Roentgenology
Verified
Journal Article
Closed access
NSNaveen Subhas
Naveen Subhas
JPJoshua M. Polster
Joshua M. Polster
NONancy A. Obuchowski
Nancy A. Obuchowski
APAndrew N. Primak
Andrew N. Primak
FDFrank F. Dong
Frank F. Dong
JIJoseph P. Iannotti
Joseph P. Iannotti
OBJECTIVE. The purpose of this study was to compare iterative metal artifact reduction (iMAR), a new single-energy metal artifact reduction technique, with filtered back projection (FBP) in terms of attenuation values, qualitative image quality, and streak artifacts near shoulder and hip arthroplasties and observer ability with these techniques to detect pathologic lesions near an arthroplasty in a phantom model. MATERIALS AND METHODS. Preoperative and postoperative CT scans of 40 shoulder and 21 hip arthroplasties were reviewed. All postoperative scans were obtained using the same technique (140 kVp, 300 quality reference mAs, 128 × 0.6 mm detector collimation) on one of three CT scanners and reconstructed with FBP and iMAR. The attenuation differences in bones and soft tissues between preoperative and postoperative scans at the same location were compared; image quality and streak artifact for both reconstructions were qualitatively graded by two blinded readers. Observer ability and confidence to detec...

1 April 2017 in American Journal of Roentgenology
Verified
Journal Article
Closed access
NSNaveen Subhas
Naveen Subhas
ABAlex Benedick
Alex Benedick
NONancy A. Obuchowski
Nancy A. Obuchowski
JPJoshua M. Polster
Joshua M. Polster
LBLuis S. Beltran
Luis S. Beltran
SGSoterios Gyftopoulos
Soterios Gyftopoulos
OBJECTIVE. The purpose of this study was to compare the diagnostic performance of a 5-minute shoulder MRI protocol consisting of multiplanar 2D fast spin-echo (FSE) sequences with parallel imaging to that of a standard shoulder MRI protocol. MATERIALS AND METHODS. A retrospective review of 151 3-T MRI examinations of shoulders of 147 patients (mean age, 46.95 years) and 50 1.5-T MRI examinations of shoulders of 50 patients (mean age, 53.74 years) with four fast and five standard sequences from two academic centers between January 2014 and April 2015 was performed by three musculoskeletal radiologists. Interchangeability of fast and standard MRI was tested by comparing interprotocol (fast vs standard) interreader agreement with standard MRI interreader agreement. Interreader agreement was also compared using kappa statistics. The frequency of major findings was compared using an adjusted McNemar test. Sensitivity and specificity of MRI were measured for 51 patients who underwent surgery. RESULTS. Interprot...

3 October 2007 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
NSNaveen Subhas
Naveen Subhas
EVEmily N. Vinson
Emily N. Vinson
RCR. Lee Cothran
R. Lee Cothran
JSJames R. Santangelo
James R. Santangelo
JNJames A. Nunley
James A. Nunley
CHClyde A. Helms
Clyde A. Helms