L. V. Petrov

L. V. Petrov

Auto-generated profile, based on publicly available information

L. V. Petrov

Siberian State Medical University

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Russian Chemical Bulletin
Verified
Journal Article
Closed access
PDF file
LPL. V. Petrov
L. V. Petrov
VSV. M. Solyanikov
V. M. Solyanikov

20 November 2011 in Petroleum Chemistry
Verified
Journal Article
Closed access
PDF file
LPL. V. Petrov
L. V. Petrov
VSV. M. Solyanikov
V. M. Solyanikov
Perchloric acid in a tert-butanol solution with 10 vol % chlorobenzene exhibits an almost three orders of magnitude higher activity in comparison with para-toluenesulfonic acid (TSA) as a catalyst for the parallel styrene epoxide (SE) heterolysis and homolysis processes. There is a substantial difference between the reactions mediated by these catalysts: rate curves for the overall consumption in the presence of perchloric acid (SE heterolysis) yield straight lines in the log [SE]-time coordinates, but the first-order rate constant drops with an increase in [SE]. However, the oxygen uptake rate increases with [SE]. In the case of TSA, neither overall consumption nor oxidation rate depended on [SE] at [SE] > [TSA]; i.e., the reaction was zeroorder in SE.

1 October 2016 in Russian Chemical Bulletin
Verified
Journal Article
Closed access
PDF file
MSM. G. Spirin
M. G. Spirin
SBS. B. Brichkin
S. B. Brichkin
LPL. V. Petrov
L. V. Petrov

1 January 2020 in Russian Journal of Physical Chemistry B
Verified
Journal Article
Closed access
PDF file
LPL. V. Petrov
L. V. Petrov
VSV. M. Solyanikov
V. M. Solyanikov
This paper describes oxidation of a ternary system (styrene epoxide (SE)—hydroquinone (Hq)—Cu(II) chloride) with oxygen in the solvent (tert-butanol/water (4 : 1 by volume)). The expression of the rate in the concentration: V = k[CuCl2]1[SE]0[Hq]0 at [SE] > [Hq] > [CuCl2] is explained by the formation of the ternary complex, antecedent of oxidation. The effective rate constant of the oxidation is k [s–1] = 92.5 exp (–22/RT) at 323–343 K. The ratio of concentration of absorbed oxygen to copper catalyst [O2] /[CuCl2] \( \gg \) 1, i.e., the oxidation is a catalytic reaction.

1 July 2021 in Russian Journal of Physical Chemistry B
Verified
Journal Article
Closed access
PDF file
LPL. V. Petrov
L. V. Petrov
VSV. M. Solyanikov
V. M. Solyanikov
Oxidation by molecular oxygen of the ternary styrene epoxide (SE)–CuCl2–ionol (IOL) system in a methanol solution is studied. It is found that the rate of oxidation V is directly proportional to [IOL], and the orders of SE and copper chloride are fractional, equal to 0.4 and 0.5, respectively. It is shown for the first time that the oxygen uptake is characteristic of analogous ternary systems, which include epoxides of a different structure instead of SE. The specificity of the action of the chloride anion in oxidation was revealed: the ternary SE–Cu(II) acetate–ionol system does not absorb oxygen. The introduction of sodium chloride into this system activates oxidation. The SE–NaCl–ionol system is not oxidized, but the introduction of Cu(II) acetate into it causes the absorption of oxygen. The experiment proves the necessity of the presence of the chloride anion for the oxidation of the ternary system.

24 May 2009 in Petroleum Chemistry
Verified
Journal Article
Closed access
PDF file
LPL. V. Petrov
L. V. Petrov
BPB. L. Psikha
B. L. Psikha
VSV. M. Solyanikov
V. M. Solyanikov
The oxidizability value of styrene epoxide as the ratio k2/√ k6, where k2 and k6 are the propagation and termination rate constants of the epoxide oxidation chain, respectively, was calculated from ex