Robert T. Chang

Robert T. Chang

Auto-generated profile, based on publicly available information

Robert T. Chang

Stanford University

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Current Opinion in Ophthalmology
Verified
Journal Article
Closed access
RCRobert T. Chang
Robert T. Chang
KSKuldev Singh
Kuldev Singh
There is strong epidemiologic evidence linking myopia with glaucomatous disease, but a myopic optic nerve can pose significant challenges with regard to making the correct diagnosis of glaucoma. This review provides an overview of these diagnostic and therapeutic challenges with a particular focus on how the growing prevalence of myopia among specific populations may impact such therapy. For a given individual, the link between myopia and glaucoma remains murky in many circumstances, largely because of the fact that it is difficult to separate out myopia-related structural and functional abnormalities from 'true' glaucomatous changes. Using optical coherence tomography (OCT) imaging, myopia has been found to be associated with temporal displacement and thinning of the superior and inferior nerve fiber layer bundles. In particular, sequential generations of 'Asian' ethnicities have been noted to demonstrate increasing rates of high myopia at earlier ages, sometimes with associated visual field defects at normal intraocular pressures. As is the case with any progressive condition, it is often not possible to distinguish glaucomatous from nonglaucomatous disease based on a single examination, and thus follow-up with OCT or perimetry from an established baseline is useful. Although myopia is a known risk factor for glaucoma, it may also result in structural and functional defects that cannot be distinguished from those caused by glaucoma based solely on cross-sectional information. Longitudinal observation may be necessary to distinguish among the multiple effects of myopia on the optic nerve and the natural history of glaucoma, which may vary substantially amongst those who are affected.

1 March 2014 in Journal of Mobile Technology in Medicine
Verified
Journal Article
Open access
PDF file
DMDavid Myung
David Myung
AJAlexandre Jais
Alexandre Jais
LHLingmin He
Lingmin He
MBMark S. Blumenkranz
Mark S. Blumenkranz
RCRobert T. Chang
Robert T. Chang
David Myung, MD, PhD1, Alexandre Jais, MS1, Lingmin He. MD, MS1, Mark S. Blumenkranz, MD1, Robert T. Chang, MD1 1Byers Eye Institute at Stanford, Stanford University School of Medicine, Stanford, California Corresponding Author: viroptic@gmail.com ...

20 March 2023 in Biomolecules
Verified
Journal Article
Open access
PDF file
MSMichelle T. Sun
Michelle T. Sun
MTMatthew Tran
Matthew Tran
KSKuldev Singh
Kuldev Singh
RCRobert Chang
Robert Chang
HWHuaizhou Wang
Huaizhou Wang
YSYang Sun
Yang Sun
The rising global prevalence of myopia is a growing concern for clinicians, as it predisposes patients to severe ocular pathologies including glaucoma. High myopia can be associated with clinical features that resemble glaucomatous damage, which make an accurate glaucoma diagnosis challenging, particularly among patients with normal intraocular pressures. These patients may also present with established visual field defects which can mimic glaucoma, and standard imaging technology is less useful in disease detection and monitoring due to the lack of normative data for these anatomically unique eyes. Progression over time remains the most critical factor in facilitating the detection of early glaucomatous changes, and thus careful longitudinal follow-up of high-risk myopic patients is the most important aspect of management. Here, we review our current understanding of the complex relationship between myopia and glaucoma, and the diagnostic challenges and limitations of current testing protocols including visual field, intraocular pressure, and imaging. Furthermore, we discuss the clinical findings of two highly myopic patients with suspected glaucoma.

15 July 2019 in SLEEP
Verified
Journal Article
Closed access
XYXiaoning Yu
Xiaoning Yu
HGHuilan Guo
Huilan Guo
XLXin Liu
Xin Liu
GWGuowei Wang
Guowei Wang
YMYan Mia Min
Yan Mia Min
KYKe Yao
Ke Yao
Study Objectives: To investigate the relationship between dry eye and sleep quality in a large community-based Chinese population.Methods: A total of 3,070 participants aged 18–80 were recruited from a community-based study in Hangzhou, China during 2016–2017. Sleep quality was evaluated using the Chinese version of the Pittsburgh Sleep Quality Index (CPSQI), and dry eye was evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. Multivariable linear regression and logistic regression models were used to investigate the associations, adjusting for age, smoking, drinking, season, and other potential confounders.Results: Overall, CPSQI score and sleep dysfunction were significantly associated with mild, moderate, and severe dry eye (ORs for CPSQI score: 1.07, 1.13, 1.14, all p < 0.001; for sleep dysfunction: 1.31, 1.73, 1.66, all p < 0.05). Furthermore, worse OSDI score was presented in participants with worse CPSQI score or sleep dysfunction (CPSQI score > 7) (β: 0.13, 0.54; all p < 0.001). In addition, six of the seven components of CPSQI showed significant associations with dry eye (all p < 0.001), except for the component of sleep medication use. Moreover, we observed significant associations of dry eye in all three subscales of OSDI with CPSQI score and sleep dysfunction.Conclusion: Our large, community-based study showed a strong association between poor sleep quality and an increased severity of dry eye, suggesting that preventing either one of the discomforts might alleviate the other.

28 January 2020 in Translational Vision Science & Technology
Verified
Journal Article
Open access
PDF file
DRDaniel B. Russakoff
Daniel B. Russakoff
SMSuria S. Mannil
Suria S. Mannil
JOJonathan D. Oakley
Jonathan D. Oakley
ARAn Ran Ran
An Ran Ran
CCCarol Y. Cheung
Carol Y. Cheung
RCRobert T. Chang
Robert T. Chang
Purpose: The purpose of this study was to develop a 3D deep learning system from spectral domain optical coherence tomography (SD-OCT) macular cubes to differentiate between referable and nonreferable cases for glaucoma applied to real-world datasets to understand how this would affect the performance. Methods: There were 2805 Cirrus optical coherence tomography (OCT) macula volumes (Macula protocol 512 × 128) of 1095 eyes from 586 patients at a single site that were used to train a fully 3D convolutional neural network (CNN). Referable glaucoma included true glaucoma, pre-perimetric glaucoma, and high-risk suspects, based on qualitative fundus photographs, visual fields, OCT reports, and clinical examinations, including intraocular pressure (IOP) and treatment history as the binary (two class) ground truth. The curated real-world dataset did not include eyes with retinal disease or nonglaucomatous optic neuropathies. The cubes were first homogenized using layer segmentation with the Orion Software (Voxeleron) to achieve standardization. The algorithm was tested on two separate external validation sets from different glaucoma studies, comprised of Cirrus macular cube scans of 505 and 336 eyes, respectively. Results: The area under the receiver operating characteristic (AUROC) curve for the development dataset for distinguishing referable glaucoma was 0.88 for our CNN using homogenization, 0.82 without homogenization, and 0.81 for a CNN architecture from the existing literature. For the external validation datasets, which had different glaucoma definitions, the AUCs were 0.78 and 0.95, respectively. The performance of the model across myopia severity distribution has been assessed in the dataset from the United States and was found to have an AUC of 0.85, 0.92, and 0.95 in the severe, moderate, and mild myopia, respectively. Conclusions: A 3D deep learning algorithm trained on macular OCT volumes without retinal disease to detect referable glaucoma performs better with retinal segmentation preprocessing and performs reasonably well across all levels of myopia. Translational Relevance: Interpretation of OCT macula volumes based on normative data color distributions is highly influenced by population demographics and characteristics, such as refractive error, as well as the size of the normative database. Referable glaucoma, in this study, was chosen to include cases that should be seen by a specialist. This study is unique because it uses multimodal patient data for the glaucoma definition, and includes all severities of myopia as well as validates the algorithm with international data to understand generalizability potential.

1 January 2016 in Indian Journal Of Ophthalmology
Verified
Journal Article
Open access
PDF file
RCRobert T Chang
Robert T Chang
CLCassieA Ludwig
CassieA Ludwig
SMSomasheilaI Murthy
SomasheilaI Murthy
RPRajeev R Pappuru
Rajeev R Pappuru
AJAlexandre Jais
Alexandre Jais
DMDavid J Myung
David J Myung
Aim of Study: To evaluate the ability of ancillary health staff to use a novel smartphone imaging adapter system (EyeGo, now known as Paxos Scope) to capture images of sufficient quality to exclude emergent eye findings. Secondary aims were to assess user and patient experiences during image acquisition, interuser reproducibility, and subjective image quality. Materials and Methods: The system captures images using a macro lens and an indirect ophthalmoscopy lens coupled with an iPhone 5S. We conducted a prospective cohort study of 229 consecutive patients presenting to L. V. Prasad Eye Institute, Hyderabad, India. Primary outcome measure was mean photographic quality (FOTO-ED study 1–5 scale, 5 best). 210 patients and eight users completed surveys assessing comfort and ease of use. For 46 patients, two users imaged the same patient's eyes sequentially. For 182 patients, photos taken with the EyeGo system were compared to images taken by existing clinic cameras: a BX 900 slit-lamp with a Canon EOS 40D Digital Camera and an FF 450 plus Fundus Camera with VISUPAC™ Digital Imaging System. Images were graded post hoc by a reviewer blinded to diagnosis. Results: Nine users acquired 719 useable images and 253 videos of 229 patients. Mean image quality was ≥ 4.0/5.0 (able to exclude subtle findings) for all users. 8/8 users and 189/210 patients surveyed were comfortable with the EyeGo device on a 5-point Likert scale. For 21 patients imaged with the anterior adapter by two users, a weighted κ of 0.597 (95% confidence interval: 0.389–0.806) indicated moderate reproducibility. High level of agreement between EyeGo and existing clinic cameras (92.6% anterior, 84.4% posterior) was found. Conclusion: The novel, ophthalmic imaging system is easily learned by ancillary eye care providers, well tolerated by patients, and captures high-quality images of eye findings.