Yoshiaki Arai

Yoshiaki Arai

Auto-generated profile, based on publicly available information

Yoshiaki Arai

Oral Implant & Temporomandibular Joint Clinic Niigata University Medical & Dental Hospital Niigata Japan

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in Journal of Prosthodontic Research
Verified
Journal Article
Closed access
MTMakiko Takashima
Makiko Takashima
YAYoshiaki Arai
Yoshiaki Arai
AKAtsushi Kawamura
Atsushi Kawamura
THTakafumi Hayashi
Takafumi Hayashi
RTRitsuo Takagi
Ritsuo Takagi
The aim of this study was to quantify masseter muscle stiffness in patients with masticatory myofascial pain. Stiffness was measured using shear wave elastography, which expresses stiffness as shear wave velocity (Vs). A phantom study was conducted to confirm the reliability of the measuring device. The study participants were 26 females with bilateral masseter muscle pain who were classified into either Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) group Ia (myofascial pain; n=13) or RDC/TMD group Ib (myofascial pain with limited opening; n=13). Healthy controls consisted of 24 female volunteers with normal teeth and jaws, who were not classified into groups I/II/III by RDC/TMD. Muscle stiffness was 1.96m/s (12.5kPa) in 13 patients in group Ia, 2.00m/s (13.0kPa) in 13 patients in group Ib and 1.27m/s (5.25kPa) in 24 control subjects. Vs was significantly greater in groups Ia and Ib than in the control group (p<0.05). Characteristic pain intensity (CPI) became clear as an independent factor impacting Vs (partial regression coefficient=0.714; multiple regression analysis , p<0.05). Masseter muscle stiffness was positively correlated with CPI (p< 0.05) and negatively correlated with maximum assisted mouth opening (p<0.05) and painless mouth opening (p<0.05). Shear wave elastography is useful to quantify masticatory muscle stiffness. Masseter muscle stiffness of females measured using shear wave elastography was about two-fold greater in group Ia and Ib than in the healthy control group.

1 January 2024 in Journal of Prosthodontic Research
Verified
Journal Article
Open access
PDF file
YAYoshiaki Arai
Yoshiaki Arai
MTMakiko Takashima
Makiko Takashima
NMNanaka Matsuzaki
Nanaka Matsuzaki
STSho Takada
Sho Takada
Purpose: Marginal bone loss (MBL) occurs in the periapical cervical bone after dental implant placement and abutment connection. MBL may not result in peri-implantitis; however, it is always accompanied by MBL. Recent studies have demonstrated that early MBL is a predictor of peri-implantitis. In this narrative review, we aimed to provide an evidence base for recommended treatment strategies for clinicians to prevent MBL.Study Selection: We reviewed the recent literature and performed a narrative synthesis of the evidence, focusing on available systematic reviews and meta-analyses of implant marginal bone resorption.Results: The available evidence indicates that certain biological, material, and technical factors can influence MBL and consequently dictate the risk of developing peri-implant disease in later years. The order of the impact of the strength of each factor is unknown. Current recommendations to prevent MBL include controlling patients’ smoking and hemoglobin A1c levels to sufficiently low levels before surgery and throughout their lifetime. Regarding the material, a platform-switching, conical-connecting implant system, and an abutment with a height of at least 2 mm should be selected. Placement should be performed using techniques that ensure sufficient soft tissue (keratinized gingival width > 2 mm, supracrestal tissue height > 3 mm), and non-undersized preparations in the cortical bone should be made with connected concave abutments during primary or secondary surgery. Patients should receive supportive peri-implant therapy during maintenance.Conclusions: MBL development is multifactorial and can be reduced by considering the biological, material, and technical factors.

1 January 2017 in Dental Materials Journal
Verified
Journal Article
Open access
PDF file
KNKosuke Nagai
Kosuke Nagai
HDHisanori Domon
Hisanori Domon
MOMasataka Oda
Masataka Oda
TSTomoe Shirai
Tomoe Shirai
TOTatsuya Ohsumi
Tatsuya Ohsumi
YAYoshiaki Arai
Yoshiaki Arai
We developed an ethylene vinyl acetate (EVA) containing surface pre-reacted glass-ionomer (S-PRG) filler, as a new mouthguard material for preventing intraoral bacterial infection. We examined its physical properties, antimicrobial activity against a major cariogenic bacterium Streptococcus mutans and a periodontopathogen Porphyromonas gingivalis, and its cytotoxicity toward human gingival epithelial cells. S-PRG filler was added to EVA copolymer at 5, 10, 20, or 40 wt% and was processed into disc-shaped test specimens. Only minor differences between the Shore hardness and rebound resilience properties of EVA materials with and without the S-PRG filler were observed. The specimens with S-PRG filler showed bacteriostatic activity toward S. mutans and P. gingivalis and inhibited S. mutans biofilm formation. No cytotoxicity against the gingival epithelial cells was observed. Our findings show that EVA containing S-PRG filler has antimicrobial activity toward pathogenic oral bacteria and may be an effective material for maintaining the oral health of athletes.

1 February 2023 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
MTMakiko Takashima
Makiko Takashima
YAYoshiaki Arai
Yoshiaki Arai
NMNanaka Matsuzaki
Nanaka Matsuzaki
YYYuta Yamazaki
Yuta Yamazaki
HNHideyoshi Nishiyama
Hideyoshi Nishiyama
KNKaname Nohno
Kaname Nohno

12 June 2025 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
YNYu Nakagawa
Yu Nakagawa
TYTaihiko Yamaguchi
Taihiko Yamaguchi
TITomoya Ishimaru
Tomoya Ishimaru
TSTaishi Saito
Taishi Saito
YHYoshinori Hattori
Yoshinori Hattori
SKShinichiro Kuroshima
Shinichiro Kuroshima

1 July 2018 in Journal of Prosthodontic Research
Verified
Journal Article
Closed access
MTMakiko Takashima
Makiko Takashima
YAYoshiaki Arai
Yoshiaki Arai
AKAtsushi Kawamura
Atsushi Kawamura
KUKatsumi Uoshima
Katsumi Uoshima
Purpose: This study analyzed risk factors for post-loading implant loss in cases of implant-supported prostheses applied to edentulous jaws of Japanese patients. Methods: In total, 245 dental implant fixtures placed in 54 edentulous jaws of 46 patients performed at Niigata University Hospital were retrospectively analyzed. Kaplan-Meier curves were used to estimate the cumulative survival rate (SR) of implants, and multiple Cox regression analysis was used to identify predictive factors of implant loss. The following risk factors for implant failure were examined: age, sex, survival time, implant length, implant location, smoking habit, bone density, bone augmentation, opposing dentition, loading period, and type of final restoration. The Cochran-Mantel-Haenszel test was used to examine difference in survival curves of the extracted predictors. Results: Sixteen implants failed during the observation period (SR = 92.8 %). Multiple Cox regression analysis revealed that male sex [hazard ratio (HR) = 16.1; p = 0.007] and use of maxillary removable restorations (HR = 12.7; p < 0.000) were risk factors for implant failure. Other factors had no significant effect on implant failure. The SR of implants for males (SR = 86.9 %) was significantly lower than that for females (SR = 99.1 %). The SR of implants for maxillary removable restorations (SR = 76.4 %) was significantly lower than for maxillary fixed restorations (SR = 99.1 %) and mandibular fixed restorations (SR = 97.8 %). Conclusions: Maxillary implants with removable restorations and male sex were risk factors for implant failure among Japanese edentulous patients. (C) 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.