1 January 2015 in Journal of Diabetes Science and Technology
Background: Although physical exercise (PE) is recommended for individuals with type 1 diabetes (DM1), participation in exercise is challenging because it increases the risk of severe hypoglycemia and the available therapeutic options to prevent it frequently result in hyperglycemia. There is no clear recommendation about the best timing for exercise. The aim of this study was to compare the risk of hypoglycemia after morning or afternoon exercise sessions up to 36 hours postworkout. Methods: This randomized crossover study enrolled subjects with DM1, older than 18 years of age, on sensor-augmented insulin pump (SAP) therapy. Participants underwent 2 moderate-intensity exercise sessions; 1 in the morning and 1 in the afternoon, separated by a 7 to 14 day wash-out period. Continuous glucose monitoring (CGM) data were collected 24 hours before, during and 36 hours after each session. Results: Thirty-five subjects (mean age 30.31 ± 12.66 years) participated in the study. The rate of hypoglycemia was significantly lower following morning versus afternoon exercise sessions (5.6 vs 10.7 events per patient, incidence rate ratio, 0.52; 95% CI, 0.43-0.63; P < .0001). Most hypoglycemic events occurred 15-24 hours after the session. On days following morning exercise sessions, there were 20% more CGM readings in near-euglycemic range (70-200 mg/dL) than on days prior to morning exercise (P = .003). Conclusions: Morning exercise confers a lower risk of late-onset hypoglycemia than afternoon exercise and improves metabolic control on the subsequent day.
6 October 2024 in Journal of Diabetes Science and Technology
Introduction: An error grid compares measured versus reference glucose concentrations to assign clinical risk values to observed errors. Widely used error grids for blood glucose monitors (BGMs) have limited value because they do not also reflect clinical accuracy of continuous glucose monitors (CGMs). Methods: Diabetes Technology Society (DTS) convened 89 international experts in glucose monitoring to (1) smooth the borders of the Surveillance Error Grid (SEG) zones and create a user-friendly tool—the DTS Error Grid; (2) define five risk zones of clinical point accuracy (A-E) to be identical for BGMs and CGMs; (3) determine a relationship between DTS Error Grid percent in Zone A and mean absolute relative difference (MARD) from analyzing 22 BGM and nine CGM accuracy studies; and (4) create trend risk categories (1-5) for CGM trend accuracy. Results: The DTS Error Grid for point accuracy contains five risk zones (A-E) with straight-line borders that can be applied to both BGM and CGM accuracy data. In a data set combining point accuracy data from 18 BGMs, 2.6% of total data pairs equally moved from Zones A to B and vice versa (SEG compared with DTS Error Grid). For every 1% increase in percent data in Zone A, the MARD decreased by approximately 0.33%. We also created a DTS Trend Accuracy Matrix with five trend risk categories (1-5) for CGM-reported trend indicators compared with reference trends calculated from reference glucose. Conclusion: The DTS Error Grid combines contemporary clinician input regarding clinical point accuracy for BGMs and CGMs. The DTS Trend Accuracy Matrix assesses accuracy of CGM trend indicators.
1 August 2019 in Diabetes Technology & Therapeutics
AMAngélica Imitola Madero
+4
Background: International consensus on the use of continuous glucose monitoring (CGM) recommends coefficient of variation (CV) as the metric of choice to express glycemic variability (GV) with a cutoff of 36% to define unstable diabetes. Even though, CV is associated with hypoglycemia in type 2 diabetes patients, the evidence on the use of one particular measure of GV in type 1 diabetes (T1DM) patients as a predictor of hypoglycemia is limited. Methods: A cohort of T1DM ambulatory patients was evaluated using CGM. Number and incidence rate of events <54 and <70 mg/dL were calculated. Bivariate and multivariate analysis of different glycemic indexes and clinical variables were performed to identify those associated with hypoglycemia. Receiver operating characteristic (ROC) curve analysis for each of the glycemic indexes was performed to define the best index and its optimal cutoff threshold to discriminate patients with events of hypoglycemia. Results: Seventy-three patients were included. A total of 128 events <54 mg/dL were recorded in 34 patients, and 350 events <70 mg/dL were registered in 51 patients. CV was the only variable significantly associated with hypoglycemia <54 mg/dL in the multivariate analysis (adjusted relative risk [aRR] 1.44, 95% confidence interval [CI]: 1.10–1.88, P = 0.008). CV, HbA1c (glycated hemoglobin), and mean glucose were associated with events <70 mg/dL. ROC curve analysis showed that, among GV metrics, CV had the best performance to discriminate patients with events <54 mg/dL (area under the curve [AUC] 0.87, 95% CI: 0.79–0.95) and events <70 mg/dL (AUC 0.79, 95% CI: 0.68–0.90) with optimal cutoff thresholds values of 34% and 31%, respectively. Among glycemic risk (GR) indexes, low blood glucose index (LBGI) showed the best performance. Conclusions: This analysis shows that CV is the best GV index, and LBGI the best GR index, to identify patients at risk of clinically significant hypoglycemia and hypoglycemia alert events in T1DM patients.
1 January 2021 in Diabetes & Metabolic Syndrome: Clinical Research & Reviews
1 March 2021 in Diabetes & Metabolic Syndrome: Clinical Research & Reviews
1 February 2017 in Diabetes Technology & Therapeutics
LCLisseth Fernanda Marín Carrillo
Lisseth Fernanda Marín Carrillo
MSMartín Alonso Rondón Sepúlveda
Martín Alonso Rondón Sepúlveda
CCCarol M. Arévalo Correa
+2
Background: Literature supports short-term efficacy and safety of Sensor Augmented Insulin Pump (SAP) therapy in patients with type 1 diabetes (T1D). However, no data are available showing long-term outcomes. Our study describes the long-term outcomes of SAP therapy with low-glucose suspend feature (SAP+LGS) in hypoglycemia in a Colombian population with T1D and hypoglycemia. Methods: A cohort study was conducted with T1D patients receiving SAP+LGS therapy who initiated this therapy because of hypoglycemia at San Ignacio University Hospital diabetes center in Bogotá, Colombia. Glycated hemoglobin (A1c) was assessed at least every 6 months, severe hypoglycemia (SH) and hypoglycemia unawareness (HU) incidence yearly. Adherence to therapy was also evaluated. Results: One hundred eleven patients were included in the analysis. Total daily insulin dose was reduced during follow-up (mean difference −0.22 U/kg; 95% confidence interval [CI] −0.18 to −0.26; P < 0.001). A1c levels were reduced from a baseline value of 8.8% ± 1.9% to 7.5% ± 1.0% at 5 months (mean difference −1.3%; 95% CI −1.09 to −1.50; P < 0.001) and 7.1% ± 0.8% (mean difference −1.7%; 95% CI −1.59 to −1.90; P < 0.001) at the end of follow-up (47 months on average). The incidence of SH and HU episodes decreased significantly since the first year, and this effect was maintained over time ( P < 0.001). Conclusions: SAP+LGS therapy in T1D patients with hypoglycemia led to a significant and sustained decrease in A1c during long periods of follow-up, as well as a significant reduction in SH and HU. Future randomized clinical trials are desired.