30 May 2019 in Journal of the American Chemical Society
1 February 2022 in Progress in Nuclear Magnetic Resonance Spectroscopy
22 August 2018 in Lab on a Chip
A generic approach is presented that allows high-resolution NMR spectroscopy of water/oil droplet emulsions in microfluidic devices. Microfluidic NMR spectroscopy has recently made significant advances due to the design of micro-detector systems and their successful integration with microfluidic devices. Obtaining NMR spectra of droplet suspensions, however, is complicated by the inevitable differences in magnetic susceptibility between the chip material, the continuous phase, and the droplet phases. This leads to broadening of the NMR resonance lines and results in loss of spectral resolution. We have mitigated the susceptibility difference between the continuous (oil) phase and the chip material by incorporating appropriately designed air-filled structures into the chip. The susceptibilities of the continuous and droplet (aqueous) phases have been matched by doping the droplet phase with a Eu3+ complex. Our results demonstrate that this leads to a proton line width in the droplet phase of about 3 Hz, enabling high-resolution NMR techniques.
21 April 2016 in Lab on a Chip
A compact microfluidic device for perfusion culture of mammalian cells under in situ metabolomic observation by NMR spectroscopy is presented. The chip is made from poly(methyl methacrylate) (PMMA), and uses a poly(dimethyl siloxane) (PDMS) membrane to allow gas exchange. It is integrated with a generic micro-NMR detector developed recently by our group [J. Magn. Reson., 2016, 262, 73–80]. While PMMA is an excellent material in the context of NMR, PDMS is known to produce strong background signals. To mitigate this, the device keeps the PDMS away from the detection area. The oxygen permeation into the device is quantified using a flow chemistry approach. A solution of glucose is mixed on the chip with a solution of glucose oxidase, before flowing through the gas exchanger. The resulting concentration of gluconate is measured by 1H NMR spectroscopy as a function of flow rate. An oxygen equilibration rate constant of 2.4 s−1 is found for the device, which is easily sufficient to maintain normoxic conditions in a cell culture at low perfusion flow rates.
27 February 2014 in Lab on a Chip
Microfluidic high-resolution NMR is possible in spite of magnetic susceptibility mismatches if appropriately shaped compensation structures are included in the chip design.
27 April 2014 in Medical & Biological Engineering & Computing