Ömür Özlenen Uçakhan

Ömür Özlenen Uçakhan

Auto-generated profile, based on publicly available information

Ömür Özlenen Uçakhan

Ankara University Faculty of Medicine, Department of Ophthalmology, Ankara, Türkiye

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2006 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
ÖUÖmür Özlenen Uçakhan
Ömür Özlenen Uçakhan
MÖMuhip Özkan
Muhip Özkan
AKAyfer Kanpolat
Ayfer Kanpolat
To compare central corneal thickness (CCT) measurements taken with the Pentacam comprehensive eye scanner (CES), noncontact specular microscopy (SM), and ultrasound pachymetry (UP) in normal and keratoconic corneas. Department of Ophthalmology, Ankara University School of Medicine, Ankara, Turkey. In a prospective study, 3 CCT measurements were taken with the Pentacam CES, SM, and UP in that sequence from 1 eye of 45 consecutive patients with myopia (group A) and 62 consecutive patients with keratoconus (group B). Eyes with keratoconus were further divided into 3 subgroups, mild, moderate, and severe, according to the mean keratometry readings. Pentacam CES (r = 0.994) and UP (r = 0.993) demonstrated very high and comparable reproducibility in group A. In group B, Pentacam CES displayed better reproducibility (r = 0.988) than UP (r = 0.969) and SM (r = 0.901). The mean CCT measurements of Pentacam CES and UP were not significantly different in group A (P = .37) and in eyes with mild keratoconus (P = .29), whereas significant differences between all instrument pairs were evident in group B and in moderate and severely keratoconic eyes (P<.05). Noncontact SM measurements were significantly smaller than those of Pentacam CES and UP in all groups (P<.05) when a measurement could be obtained. There were significant linear correlations between CCT measurements of Pentacam CES, UP, and noncontact SM in groups A, B, and mildly keratoconic eyes (P<.001). Results suggest that whereas Pentacam CES and UP may be used interchangeably in normal eyes in the clinical setting for the measurement of CCT, one should be cautious interpreting corneal thickness data from Pentacam CES, UP, and particularly SM in eyes with keratoconus. Whereas, in normal and mildly keratoconic eyes, Pentacam CES and UP demonstrated very high and comparable reproducibility, in moderately keratoconic eyes, Pentacam CES readings showed better reproducibility than UP.

1 July 2006 in Eye & Contact Lens: Science & Clinical Practice
Verified
Journal Article
Closed access
ÖUÖmür Ö. Uçakhan
Ömür Ö. Uçakhan
AKAyfer Kanpolat
Ayfer Kanpolat
NYNurgül Ylmaz
Nurgül Ylmaz
MÖMuhip Özkan
Muhip Özkan
: To evaluate corneal structure in eyes with keratoconus by using in vivo confocal microscopy. : In a prospective institutional study, 48 eyes of 24 consecutive patients with keratoconus were examined by in vivo confocal microscopy. Forty-four eyes of 22 healthy subjects served as the control. The main outcome measures were qualitative and quantitative changes encountered at confocal microscopy examination. : In the keratoconus group, in vivo confocal microscopy findings included elongated, exfoliating superficial epithelial cells; brightly reflective material deposition within the basal epithelial cells; prominent, thickened subbasal nerves; structural changes in subbasal nerve fibers; pronounced reflectivity and irregular arrangement of stromal keratocytes; structurally abnormal anterior stromal keratocyte nuclei; folds in the anterior, mid, and posterior stroma; folds in Descemet's membrane; pleomorphism and enlargement of endothelial cells; and endothelial guttata. No such abnormal findings were present in the control group. There were significant differences between the two groups in terms of the mean basal epithelial, anterior and posterior stromal keratocyte densities, the mean basal epithelial cell area, and the mean endothelial cell hexagonality percentages. : Quantitative and qualitative structural changes were observed in all corneal layers in eyes with keratoconus by using slit-scanning confocal microscopy. The changes at all levels were more prominent in eyes with severe keratoconus. This noninvasive in vivo technique may prove to be useful in the diagnosis and follow-up of keratoconus and in the understanding of its pathophysiology.

1 March 2002 in Cornea
Verified
Journal Article
Closed access
ÖUÖmür Ö. Uçakhan
Ömür Ö. Uçakhan
GKGültekin Köklü
Gültekin Köklü
EFEsin Firat
Esin Firat
To evaluate the safety and efficacy of nonpreserved amniotic membrane transplantation (AMT) with or without limbal autograft transplantation (LAT) in management of acute and chronic chemical eye injuries. Amniotic membrane transplantation or AMT + LAT was performed on nine eyes of seven consecutive patients, five eyes with acute chemical burn and four eyes with limbal stem cell deficiency secondary to previous chemical burn. Nonpreserved amniotic membrane was used in all procedures. Five patients (71.5%) were men and two (28.5%) were women. The average age at the time of surgery was 32.7 ± 10.9 years (range, 20–45). Mean follow-up after last surgery was 8.9 ± 3.2 months (range, 6–14). The average epithelial healing time was 24.6 ± 17.3 days (range, 3–45). At the end of the follow-up period, visual acuity improved in all eyes, inflammation subsided, and the subjective complaints decreased remarkably. AMT with nonpreserved amniotic membrane promoted epithelial healing, reduced surface inflammation, increased patient comfort, and decreased the extent and severity of vascularization when used in patients with acute chemical burns. When used in limbal stem cell deficiency owing to past chemical burns, AMT alone or in combination with LAT aided in ocular surface reconstruction. Infectious, inflammatory, or toxic/allergic reactions were not encountered in any patient owing to the use of nonpreserved amniotic membrane. Further studies are required to establish the safety and efficacy of preserved and nonpreserved AMT in ocular surface reconstruction.

1 February 2016 in Cornea
Verified
Journal Article
Closed access
ÖUÖmür Ö. Uçakhan
Ömür Ö. Uçakhan
BBBetül N. Bayraktutar
Betül N. Bayraktutar
ASAyhan Saglik
Ayhan Saglik
Purpose: To evaluate the long-term visual, refractive, and topographic outcomes of corneal collagen cross-linking (CXL) in the management of pediatric keratoconus. Methods: Forty eyes of 40 consecutive patients with progressive keratoconus aged below 19 years were enrolled in this prospective study. All patient eyes underwent CXL with the standard (Dresden) protocol. Uncorrected distance visual acuity, best spectacle-corrected distance visual acuity, manifest refraction, slit-lamp biomicroscopy, corneal topography, corneal aberrometry, and endothelial cell counts were evaluated at baseline and at all postoperative follow-up examinations until month 48. Results: Mean age of patients was 15.2 ± 1.9 years (10–18 years). Follow-up was 4 years. The mean improvements in uncorrected distance visual acuity (from 0.9 ± 0.3 logMAR to 0.5 ± 0.3 logMAR) and best spectacle-corrected distance visual acuity (from 0.4 ± 0.2 logMAR to 0.1 ± 0.1 logMAR) were statistically significant at month 48 (P = 0.0001). The mean Kmax decreased from 58.4 ± 5.5 D at baseline to 57.0 ± 5.3 D at month 48 (P = 0.04). Significant improvements in topographic and elevation indices and corneal aberrations were also noted after postoperative month 6. There was no change in the mean endothelial cell density (P > 0.05), and there was no progression or sight-threatening complication in any patient eye. Conclusions: Corneal CXL seems to be safe and effective in halting the progression of keratoconus in pediatric patients at 4-year follow-up. In addition, the procedure provides improvements in visual, refractive, topographic, and corneal aberrometric measurements.

21 July 2009 in Acta Ophthalmologica
Verified
Journal Article
Closed access
PDF file
ÖUÖzlenen Ö. Uçakhan
Özlenen Ö. Uçakhan
MÖMuhip Özkan
Muhip Özkan
AKAyfer Kanpolat
Ayfer Kanpolat

1 November 2008 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
ÖUÖmür Ö. Uçakhan
Ömür Ö. Uçakhan
PGPelin Gesoğlu
Pelin Gesoğlu
MÖMuhip Özkan
Muhip Özkan
AKAyfer Kanpolat
Ayfer Kanpolat
To prospectively evaluate the elevation and thickness data in patients with different types of refractive errors. Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey. After the refractive errors in 215 consecutive patients were determined, corneal topography measurements with the Pentacam Scheimpflug system were taken in the right eye of all patients and the right eye of 31 healthy emmetropic volunteers. The eyes with refractive errors were assigned to 1 of the following 4 groups: myopia, myopic astigmatism, high myopia, and hyperopia. The means of the parameters of 3 Pentacam measurements were evaluated and compared. Eyes with high myopia had significantly lower mean corneal thickness and volume measurements and higher mean anterior chamber depth (ACD) and anterior chamber volume (ACV) measurements than eyes in the other groups. The mean ACD, ACV, and anterior chamber angle were significantly lower in hyperopic eyes than in the other groups. The mean keratometry readings were statistically significantly flatter in the hyperopia group than in the other 4 groups. Eyes with high myopia had thinner corneas and deeper anterior chambers than emmetropic eyes and eyes in the other ametropic groups. Excluding eyes with hyperopia, which had significantly flat anterior and posterior elevation measurements, the elevation measurements in eyes with myopic refractive errors did not differ from each other or from those in emmetropic eyes. These findings may help clinicians and refractive surgeons using the Pentacam to better define normal from abnormal in the clinical setting.