Holger Stark

Holger Stark

Auto-generated profile, based on publicly available information

Holger Stark

Department of Structural Dynamics, MPI for Biophysical Chemistry, Göttingen, Germany

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2009 in Nature
Verified
Journal Article
Closed access
PDF file
EAEbbe S. Andersen
Ebbe S. Andersen
Mingdong DongMingdong Dong
Mingdong Dong
MNMorten M. Nielsen
Morten M. Nielsen
KJKasper Jahn
Kasper Jahn
RSRamesh Subramani
Ramesh Subramani
JKJørgen Kjems
Jørgen Kjems

21 October 2020 in Nature
Verified
Journal Article
Closed access
PDF file
KYKa Man Yip
Ka Man Yip
NFNiels Fischer
Niels Fischer
EPElham Paknia
Elham Paknia
ACAshwin Chari
Ashwin Chari
HSHolger Stark
Holger Stark

23 December 2007 in Nature Methods
Verified
Journal Article
Closed access
PDF file
BKBerthold Kastner
Berthold Kastner
NFNiels Fischer
Niels Fischer
MGMonika Mariola Golas
Monika Mariola Golas
BSBjoern Sander
Bjoern Sander
PDPrakash Dube
Prakash Dube
HSHolger Stark
Holger Stark

1 November 2000 in Quarterly Reviews of Biophysics
Verified
Journal Article
Open access
PDF file
MHMarin van Heel
Marin van Heel
BGBrent Gowen
Brent Gowen
RMRishi Matadeen
Rishi Matadeen
EOElena V. Orlova
Elena V. Orlova
RFRobert Finn
Robert Finn
APArdan Patwardhan
Ardan Patwardhan
1. Introduction 3082. Electron microscopy 3112.1 Specimen preparation 3112.2 The electron microscope 3112.3 Acceleration voltage, defocus, and the electron gun 3122.4 Magnification and data collection 3133. Digitisation and CTF correction 3173.1 The patchwork densitometer 3183.2 Particle selection 3203.3 Position dependent CTF correction 3213.4 Precision of CTF determination 3214. Single particles and angular reconstitution 3234.1 Preliminary filtering and centring of data 3234.2 Alignments using correlation functions 3244.3 Choice of first reference images 3244.4 Multi-reference alignment of data 3254.5 MSA eigenvector/eigenvalue data compression 3284.6 MSA classification 3304.7 Euler angle determination (‘angular reconstitution’) 3324.8 Sinograms and sinogram correlation functions 3324.9 Exploiting symmetry 3354.10 Three-dimensional reconstruction 3374.11 Euler angles using anchor sets 3394.12 Iterative refinements 3395. Computational hardware/software aspects 3415.1 The (IMAGIC) image processing workstation 3425.2 Operating systems and GUIs 3425.3 Computational logistics 3445.4 Shared memory machines 3445.5 Farming on loosely coupled computers 3465.6 Implementation using MPI protocol 3475.7 Software is what it's all about 3476. Interpretation of results 3486.1 Assessing resolution: the Fourier Shell Correlation 3486.2 Influence of filtering 3516.3 Rendering 3516.4 Searching for known sub-structures 3526.5 Interpretation 3537. Examples 3537.1 Icosahedral symmetry: TBSV at 5·9 Å resolution 3547.2 The D6 symmetrical worm hemoglobin at 13 Å resolution 3567.3 Functional states of the 70S E. coli ribosome 3577.4 The 50S E. coli ribosomal subunit at 7·5 Å resolution 3598. Perspectives 3619. Acknowledgements 36410. References 364In the past few years, electron microscopy (EM) has established itself as an important – still upcoming – technique for studying the structures of large biological macromolecules. EM is a very direct method of structure determination that complements the well-established techniques of X-ray crystallography and NMR spectroscopy. Electron micrographs record images of the object and not just their diffraction patterns and thus the classical ‘phase’ problem of X-ray crystallography does not exist in EM. Modern microscopes may reach resolution levels better than ∼ 1·5 Å, which is more than sufficient to elucidate the polypeptide backbone in proteins directly. X-ray structures at such resolution levels are considered ‘excellent’. The fundamental problem in biological EM is not so much the instrumental resolution of the microscopes, but rather the radiation sensitivity of the biological material one wants to investigate. Information about the specimen is collected in the photographic emulsion with the arrival of individual electrons that have (elastically) interacted with the specimen. However, many electrons will damage the specimen by non-elastic interactions. By the time enough electrons have passed through the object to produce a single good signal-to-noise (SNR) image, the biological sample will have been reduced to ashes. In contrast, stable inorganic specimens in material science often show interpretable details down to the highest possible instrumental resolution.

18 July 2007 in Nature
Verified
Journal Article
Closed access
MSMinhajuddin Sirajuddin
Minhajuddin Sirajuddin
MFMarian Farkasovsky
Marian Farkasovsky
FHFlorian Hauer
Florian Hauer
DKDorothee Kühlmann
Dorothee Kühlmann
IMIan G. Macara
Ian G. Macara
AWAlfred Wittinghofer
Alfred Wittinghofer

30 April 2010 in Science
Verified
Journal Article
Closed access
PDF file
JHJames R. A. Hutchins
James R. A. Hutchins
YTYusuke Toyoda
Yusuke Toyoda
BHBjörn Hegemann
Björn Hegemann
IPIna Poser
Ina Poser
JHJean-Karim Hériché
Jean-Karim Hériché
JPJan-Michael Peters
Jan-Michael Peters
Division Machinery Tagged: An international consortium of labs has been testing the feasibility of large-scale screening for insights into the function of mammalian proteins by expressing a tagged version of proteins from bacterial artificial chromosomes harbored in mammalian cells. Depending on the tag used, Hutchins et al. (p. 593 , published online 1 April) were able to monitor localization of tagged proteins by microscopy or to isolate interacting proteins and subsequently identify the binding partners by mass spectrometry. Applying the technology to proteins implicated in control of cell division revealed about 100 protein machines required for mitosis.