1 March 2018 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Open access
CMCharles S. Mayo
Charles S. Mayo
JMJean M. Moran
Jean M. Moran
WBWalter Bosch
Walter Bosch
YXYing Xiao
Ying Xiao
TMTodd McNutt
Todd McNutt
TYTorunn I. Yock
Torunn I. Yock
A substantial barrier to the single- and multi-institutional aggregation of data to supporting clinical trials, practice quality improvement efforts, and development of big data analytics resource systems is the lack of standardized nomenclatures for expressing dosimetric data. To address this issue, the American Association of Physicists in Medicine (AAPM) Task Group 263 was charged with providing nomenclature guidelines and values in radiation oncology for use in clinical trials, data-pooling initiatives, population-based studies, and routine clinical care by standardizing: (1) structure names across image processing and treatment planning system platforms; (2) nomenclature for dosimetric data (eg, dose-volume histogram [DVH]-based metrics); (3) templates for clinical trial groups and users of an initial subset of software platforms to facilitate adoption of the standards; (4) formalism for nomenclature schema, which can accommodate the addition of other structures defined in the future. A multisociety, multidisciplinary, multinational group of 57 members representing stake holders ranging from large academic centers to community clinics and vendors was assembled, including physicists, physicians, dosimetrists, and vendors. The stakeholder groups represented in the membership included the AAPM, American Society for Radiation Oncology (ASTRO), NRG Oncology, European Society for Radiation Oncology (ESTRO), Radiation Therapy Oncology Group (RTOG), Children's Oncology Group (COG), Integrating Healthcare Enterprise in Radiation Oncology (IHE-RO), and Digital Imaging and Communications in Medicine working group (DICOM WG); A nomenclature system for target and organ at risk volumes and DVH nomenclature was developed and piloted to demonstrate viability across a range of clinics and within the framework of clinical trials. The final report was approved by AAPM in October 2017. The approval process included review by 8 AAPM committees, with additional review by ASTRO, European Society for Radiation Oncology (ESTRO), and American Association of Medical Dosimetrists (AAMD). This Executive Summary of the report highlights the key recommendations for clinical practice, research, and trials.

8 November 2016 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
ECElizabeth L. Covington
Elizabeth L. Covington
XCXiaoping Chen
Xiaoping Chen
KYKelly C. Younge
Kelly C. Younge
CLChoonik Lee
Choonik Lee
MMMartha M. Matuszak
Martha M. Matuszak
JMJean M. Moran
Jean M. Moran
The goal of this work is to evaluate the effectiveness of Plan‐Checker Tool (PCT) which was created to improve first‐time plan quality, reduce patient delays, increase the efficiency of our electronic workflow, and standardize and automate the physics plan review in the treatment planning system (TPS). PCT uses an application programming interface to check and compare data from the TPS and treatment management system (TMS). PCT includes a comprehensive checklist of automated and manual checks that are documented when performed by the user as part of a plan readiness check for treatment. Prior to and during PCT development, errors identified during the physics review and causes of patient treatment start delays were tracked to prioritize which checks should be automated. Nineteen of 33 checklist items were automated, with data extracted with PCT. There was a 60% reduction in the number of patient delays in the six months after PCT release. PCT was successfully implemented for use on all external beam treatment plans in our clinic. While the number of errors found during the physics check did not decrease, automation of checks increased visibility of errors during the physics check, which led to decreased patient delays. The methods used here can be applied to any TMS and TPS that allows queries of the database.PACS number(s): 87.55.‐x, 87.55.N‐, 87.55.Qr, 87.55.tm, 89.20.Bb

16 May 2019 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
ECElizabeth L. Covington
Elizabeth L. Covington
JFJohn B. Fiveash
John B. Fiveash
XWXingen Wu
Xingen Wu
IBIvan Brezovich
Ivan Brezovich
CWChristopher D Willey
Christopher D Willey
RPRichard A. Popple
Richard A. Popple
Purpose: To evaluate the accuracy of monitoring intrafraction motion during stereotactic radiotherapy with the optical surface monitoring system. Prior studies showing a false increase in the magnitude of translational offsets at non‐coplanar couch positions prompted the vendor to implement software changes. This study evaluated two software improvements intended to address false offsets.Methods: The vendor implemented two software improvements: a volumetric (ACO) rather than planar calibration and, approximately 6 months later, an improved calibration workflow (CIB) designed to better compensate for thermal drift. Offsets relative to the reference position, obtained at table angle 0 following image‐guided setup, were recorded before beam‐on at each table position and at the end of treatment the table returned to 0° for patients receiving SRT.Results: Prior to ACO, between ACO and CIB, and after CIB, 223, 155, and 436 fractions were observed respectively. The median magnitude of translational offsets at the end of treatment was similar for all three intervals: 0.29, 0.33, and 0.27 mm. Prior to ACO, the offset magnitude for non‐zero table positions had a median of 0.79 mm and was found to increase with increasing distance from isocenter to the anterior patient surface. After ACO, the median magnitude was 0.74 mm, but the dependence on surface‐to‐isocenter distance was eliminated. After CIB, the median magnitude for non‐zero table positions was reduced to 0.57 mm.Conclusion: Ongoing improvements in software and calibration procedures have decreased reporting of false offsets at non‐zero table angles. However, the median magnitude for non‐zero table angles is larger than that observed at the end of treatment, indicating that accuracy remains better when the table is not rotated.

22 January 2020 in Medical Physics
Verified
Journal Article
Open access
PDF file
ECElizabeth L. Covington
Elizabeth L. Covington
JMJean M. Moran
Jean M. Moran
KPKelly C. Paradis
Kelly C. Paradis
The purpose of this study was to quantify gender diversity in leadership positions within the field of medical physics, as well as within award categories and other recognitions by the American Association of Physicists in Medicine. The April 2019 PDF version of the AAPM membership directory was searched for all users self‐reporting as holding a leadership position at their place of employment, those elected to leadership positions within the AAPM, those serving as chair of an AAPM council, and those listed as having received an award or other such recognition from AAPM (beginning in 1972 with the William D. Coolidge Award). Historical data for these categories were obtained from archived membership directories on the AAPM website. The AAPM website was also used to identify members who have served on the Medical Physics Editorial Board. The Commission on Accreditation of Medical Physics Education Programs (CAMPEP) website was used to identify the current directors of graduate and residency programs (as of July 2019). Because gender was not a reported field in any of these categories, gender was assigned by reviewing names and photographs. Percentage representation in these respects was compared to the overall percentage of women in the AAPM in 2019 (23.3%) and reported the number of women working as medical physicists globally (29.8%). Within the AAPM, the percentage of women reporting clinical leadership roles is 12.0% within the US, 13.6% in Canada, and 18.0% in all other countries combined. Women comprise only 7.5% of CAMPEP graduate program directors and 21.5% of residency program directors. The percentage of female presidents in AAPM is 8.1%. A woman has never served as Editor‐in‐Chief of Medical Physics, and the average for the past 10 yr for female board membership is 13.6%. With the exception of the John R. Cameron Young Investigators Symposium Award, the percentage of all female AAPM awardees is less than the percentage of women AAPM members. The lowest percentage of female representation within AAPM is among council chairs with only one woman having held a chair position out of 42 positions (2.4%) from 1970 to July 2019. Similar to the traditional discipline of physics, medical physics displays a clear gender disparity with regard to leadership positions, both within educational training programs and the AAPM. Further investigation into the demographics of the field and psychosocial factors affecting medical physicists may help to elucidate the origin of these disparities and inform strategies to address them.

23 October 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
ECElizabeth L. Covington
Elizabeth L. Covington
DSDennis N. Stanley
Dennis N. Stanley
JFJohn B. Fiveash
John B. Fiveash
ETEvan M. Thomas
Evan M. Thomas
SMSamuel R. Marcrom
Samuel R. Marcrom
RPRichard A. Popple
Richard A. Popple
Purpose: To report on the use of surface guided imaging during frameless intracranial stereotactic radiotherapy with automated delivery via HyperArcTM (Varian Medical Systems, Palo Alto, CA).Methods: All patients received intracranial radiotherapy with HyperArcTM and were monitored for intrafraction motion by the AlignRT® (VisionRT, London, UK) surface imaging (SI) system. Immobilization was with the EncompassTM (Qfix, Avondale, PA) aquaplast mask device. AlignRT® log files were correlated with trajectory log files to correlate treatment parameters with SI reported offsets. SI reported offsets were correlated with gantry angle and analyzed for performance issues at non‐zero couch angles and during camera‐pod blockage during gantry motion. Demographics in the treatment management system were used to identify race and determine if differences in SI reported offsets are due to skin tone settings.Results: A total of 981 fractions were monitored over 14 months and 819 were analyzed. The median AlignRT® reported motion from beginning to the end of treatment was 0.24 mm. The median offset before beam on at non‐zero couch angles was 0.55 mm. During gantry motion when camera pods are blocked, the median magnitude was below 1 mm. Median magnitude of offsets at non‐zero couch angles was not found to be significantly different for patients stratified by race.Conclusions: Surface image guidance is a viable alternative to scheduled mid‐treatment imaging for monitoring intrafraction motion during stereotactic radiosurgery with automated delivery.

8 January 2016 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
SHScott W. Hadley
Scott W. Hadley
MKMarc L. Kessler
Marc L. Kessler
DLDale W. Litzenberg
Dale W. Litzenberg
CLChoonik Lee
Choonik Lee
JIJim Irrer
Jim Irrer
JMJean M. Moran
Jean M. Moran
Proper quality assurance (QA) of the radiotherapy process can be time‐consuming and expensive. Many QA efforts, such as data export and import, are inefficient when done by humans. Additionally, humans can be unreliable, lose attention, and fail to complete critical steps that are required for smooth operations. In our group we have sought to break down the QA tasks into separate steps and to automate those steps that are better done by software running autonomously or at the instigation of a human. A team of medical physicists and software engineers worked together to identify opportunities to streamline and automate QA. Development efforts follow a formal cycle of writing software requirements, developing software, testing and commissioning. The clinical release process is separated into clinical evaluation testing, training, and finally clinical release. We have improved six processes related to QA and safety. Steps that were previously performed by humans have been automated or streamlined to increase first‐time quality, reduce time spent by humans doing low‐level tasks, and expedite QA tests. Much of the gains were had by automating data transfer, implementing computer‐based checking and automation of systems with an event‐driven framework. These coordinated efforts by software engineers and clinical physicists have resulted in speed improvements in expediting patient‐sensitive QA tests.PACS number(s): 87.55.Ne, 87.55.Qr, 87.55.tg, 87.55.tm