1 September 2001 in Journal of Refractive Surgery
PURPOSE: To relate the change of ocular aberrations with the change of visual performance produced by standard laser in situ keratomileusis (LASIK) for myopia. METHODS: Aberrations and visual performance were measured before and after surgery in 22 eyes. Total aberrations were measured using a laser ray tracing technique. Corneal aberrations were obtained using a commercial videokeratoscope and custom software. Visual performance was evaluated in terms of best spectacle-corrected contrast sensitivity and high-contrast visual acuity. RESULTS: The amount of total and corneal aberrations increased with LASIK in all except two eyes. In general, the total and corneal aberration patterns were well-correlated after LASIK. However, the anterior corneal surface alone did not capture all the information (ie, possible changes induced on the posterior corneal surface or interactions between the different ocular components), which suggests that total aberrations are better predictors of visual performance. The decrease of the modulation transfer function (both in terms of area under the curve or as a function of spatial frequency) with LASIK accounted for most of the decrease in contrast sensitivity. High-resolution visual acuity was not very sensitive to the LASIKinduced changes in image quality. CONCLUSION: Wavefront and total aberration measurements, and in particular a combination of the two techniques, provide useful information for understanding the optical changes induced by standard refractive surgery. Predictions of the change in modulation transfer function derived from wave aberrations matched measurements of change in contrast sensitivity. [J Refract Surg 2001 ;17: S596-S601]
1 May 2005 in Journal of Refractive Surgery
PURPOSE: To compare experimental optical performance in eyes implanted with spherical and aspheric intraocular lenses (IOLs). METHODS: Corneal, total, and internal aberrations were measured in 19 eyes implanted with spherical (n=9) and aspheric (n=10) IOLs. Corneal aberrations were estimated by virtual ray tracing on corneal elevation maps, and total aberrations were measured using a second -generation laser ray tracing system. Corneal and total wave aberrations were fit to a Zernike polynomial expansion. Internal aberrations were measured by subtracting corneal from total wave aberrations. Optical performance was evaluated in terms of root-meansquare (RMS) wavefront error and Strehl ratio (estimated from the modulation transfer function). Depth-of-field was obtained from through-focus Strehl estimates from each individual eye. RESULTS: Corneal aberrations increased after I OL implantation, particularly astigmatism and trefoil terms. Third and higher order RMS (and the corresponding Strehl ratio) were significantly better in eyes with aspheric IOLs than with spherical IOLs; however, this tendency was reversed when astigmatism was included. Spherical aberration was not significantly different in eyes with aspheric IOLs, whereas it was significantly positive in eyes with spherical IOLs. Third order aberrations were not significantly different across groups. Depth-of-field was significantly larger in eyes with spherical IOLs. Spherical IOLs showed better absolute optical quality in the presence of negative defocus > 1.00 D. CONCLUSIONS: Our study shows a good degree of compensation of the corneal spherical aberration in eyes implanted with aspheric IOLs, as opposed to eyes implanted with spherical IOLs. Other sources of optical degradation, both with aspheric and spherical IOLs, are non-symmetric preoperative corneal aberrations, incision-induced aberrations, and third order internal aberrations. Although best corrected optical quality is significantly better with aspheric IOLs, tolerance to defocus tended to be lower. [J Refract Surg. 2005;21:223-235.]
1 August 2010 in Investigative Ophthalmology & Visual Science
Purpose.: Understanding corneal biomechanics is important to refractive or therapeutic corneal treatments. The authors studied the corneal response to variable intraocular pressure (IOP) in porcines eyes after UV collagen cross-linking (CXL), in comparison with untreated eyes. Methods.: Twenty-three enucleated eyes were treated with standard CXL conditions (365 nm, 3 mW, 30 minutes), and 15 contralateral eyes served as control. Eyes (within a humidity- and temperature-monitored wet chamber) were measured by Scheimpflug corneal three-dimensional topographer. Images were obtained automatically while IOP either remained constant (14 eyes) or increased (24 eyes) by 40 mm Hg and then decreased (4-mm Hg steps). Measurements were performed immediately after treatment and 24 hours later. Corneal geometry was analyzed as a function of IOP, and whole globe stress-strain curves were calculated. Results.: Instillation of riboflavin-dextran solution reduced corneal thickness (by 281 ± 5 μm). Cross-linking produced a 1.54× reduction in corneal thinning and 2.8× reduction in corneal apical rise with increased IOP. Anterior and posterior cornea flattened with increased IOP (less flattening in CXL eyes) and became steeper with decreased IOP. The horizontal meridian flattened significantly (P < 0.01) more than the vertical meridian. Young's modulus was higher in cross-linked eyes (1.096 ± 0.30 kN/m2) than in non–cross-linked eyes (0.692 ± 0.30 kN/m2). Hysteresis in nontreated eyes was also larger than in cross-linked eyes. Conclusions.: Cross-linking stiffened porcine corneas significantly. Both experimental data and stress-strain analysis are valuable for finite element models to improve understanding of CXL and its predictability. Although differences are expected between human corneas in vivo and porcine corneas ex vivo, the results are consistent with clinical data found in patients. The apparent biomechanical anisotropy of pig corneas must be confirmed in humans.
1 August 2006 in Journal of Vision
We present a comparison between measurements of the radius of the anterior and posterior lens surface, which was performed using corrected Scheimpflug imaging and Purkinje imaging in the same group of participants (46 for the anterior lens, and 34 for the posterior lens). Comparisons were also made as a function of accommodation (0 to 7 D) in a subset of 11 eyes. Data were captured and processed using laboratory prototypes and custom processing algorithms [for optical and geometrical distortion correction in the Scheimpflug system and using either equivalent mirror (EM) or merit function (MF) methods for Purkinje]. We found statistically significant differences in 4 of 46 eyes for the anterior lens radius, and 10 of 34 eyes for the posterior radius (using the MF and individual biometric data to process the Purkinje images). For the anterior lens, the agreement increases using individual biometry as opposed to biometric data from a model eye. For the posterior lens, the agreement increases using the MF as opposed to the EM method. For the changes during accommodation, no significant difference between the two techniques was found. In conclusion, the results of the cross-validation using the Scheimpflug and Purkinje imaging technique show that both techniques provide comparable lens radii and similar changes with accommodation. Purkinje tends to overestimate posterior lens radius, whereas pupil size limits the acquisition of posterior lens data with the Scheimpflug camera. Computer simulations using the Scheimpflug data as input show that the consistent slight overestimation of the posterior lens radius using Purkinje imaging can be partly attributed to the asphericity of the lens surface.
1 October 2003 in Journal of the Optical Society of America A
Corneal and ocular aberrations were measured in a group of eyes before and after cataract surgery with spherical intraocular lens (IOL) implantation by use of well-tested techniques developed in our laboratory. By subtraction of corneal from total aberration maps, we also estimated the optical quality of the intraocular lens in vivo. We found that aberrations in pseudophakic eyes are not significantly different from aberrations in eyes before cataract surgery or from previously reported aberrations in healthy eyes of the same age. However, aberrations in pseudophakic eyes are significantly higher than in young eyes. We found a slight increase of corneal aberrations after surgery. The aberrations of the IOL and the lack of balance of the corneal spherical aberrations by the spherical aberrations of the intraocular lens also degraded the optical quality in pseudophakic eyes. We also measured the aberrations of the IOL in vitro, using an eye cell model, and simulated the aberrations of the IOL on the basis of the IOL’s physical parameters. We found a good agreement among in vivo, in vitro, and simulated measures of spherical aberration: Unlike the spherical aberration of the young crystalline lens, which tends to be negative, the spherical aberration of the IOL is positive and increases with lens power. Computer simulations and in vitro measurements show that tilts and decentrations might be contributors to the increased third-order aberrations in vivo in comparison with in vitro measurements.
14 August 2014 in PLOS ONE
Biomechanical properties are an excellent health marker of biological tissues, however they are challenging to be measured in-vivo. Non-invasive approaches to assess tissue biomechanics have been suggested, but there is a clear need for more accurate techniques for diagnosis, surgical guidance and treatment evaluation. Recently air-puff systems have been developed to study the dynamic tissue response, nevertheless the experimental geometrical observations lack from an analysis that addresses specifically the inherent dynamic properties. In this study a viscoelastic finite element model was built that predicts the experimental corneal deformation response to an air-puff for different conditions. A sensitivity analysis reveals significant contributions to corneal deformation of intraocular pressure and corneal thickness, besides corneal biomechanical properties. The results show the capability of dynamic imaging to reveal inherent biomechanical properties in vivo. Estimates of corneal biomechanical parameters will contribute to the basic understanding of corneal structure, shape and integrity and increase the predictability of corneal surgery.